3.5-ton central heat pump · NS17H
GE NS17H42SA4-**A
Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.
Ranks #92 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,294 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.6 Cooling efficiency over a seasonBelow average · beats 17%
- HSPF2
- 8.3 Heating efficiency over a seasonBelow average · beats 30%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 21,800 BTU/h52% of its 47°F outputVery good · beats 76%
A good fit if…
- You want a choice of indoor units - 52 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS17H42SA4-**A |
| Series | NS17H |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.6 (range 15.2-15.6) |
| EER2Efficiency at 95°F outdoors | 12.5-13.0 |
| Cooling capacity | 40,500-42,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.3 |
| Capacity at 47°F | 37,600-42,000 BTU/h |
| Capacity at 17°F | 25,000-27,600 BTU/h |
| Capacity at 5°F | 19,600-21,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.20 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM42V2TA4 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NAM42V2TA4 | - | 15.6 | 13.0 | 8.3 | 20,600 | 210677859 |
| NCDC48CT4+TDR | NF80D110S5C-* | 15.6 | 13.0 | 8.3 | 21,800 | 213355845 |
| NCDC48CT5D-**+TDR | NF80D110S5C* | 15.6 | 13.0 | 8.3 | 21,800 | 217490932 |
| NCUU49CP4+TDR+TXV | NF80X100V5C-* | 15.6 | 13.0 | 7.8 | 19,900 | 210262453 |
| NCUC49CT4+TDR | NF80X100V5C-* | 15.6 | 13.0 | 7.8 | 19,900 | 210262463 |
| NCUC49CT5D-**+TDR | NF80X100V5C* | 15.6 | 13.0 | 7.8 | 19,900 | 217491209 |
| NCHC42BT5D-**+TDR | NF80U090T4B* | 15.6 | 13.0 | 7.8 | 19,900 | 217491093 |
| NCUC48CT5D-**+TDR | NF80X100V5C* | 15.6 | 13.0 | 7.8 | 19,700 | 217491208 |
| NCUC48CT5D-**+TDR | NF80U110T5C* | 15.6 | 13.0 | 7.8 | 19,600 | 217491124 |
| NAM42V1TA4 | - | 15.4 | 13.0 | 8.1 | 20,200 | 210720481 |
| NAM42V1TA5D- | - | 15.4 | 13.0 | 8.1 | 20,200 | 217490918 |
| NCHC42BT5D-**+TDR | NF80X080V4B* | 15.4 | 13.0 | 8.0 | 20,200 | 217491194 |
| NCUU49CP4+TDR+TXV | NF80U110S5C-* | 15.4 | 12.5 | 7.8 | 19,800 | 210262450 |
| NCUC49CT4+TDR | NF80U110T5C-* | 15.4 | 13.0 | 7.8 | 19,900 | 210262458 |
| NCUC49CT4+TDR | NF80U110S5C-* | 15.4 | 12.5 | 7.8 | 19,800 | 210262460 |
| NCHC48CT4+TDR | NF80X100V5C-* | 15.4 | 13.0 | 7.8 | 20,200 | 210262457 |
| NCUU49CP4+TDR+TXV | NF80U090S5C-* | 15.4 | 12.5 | 7.8 | 19,800 | 210262449 |
| NCUC49CT4+TDR | NF80U090S5C-* | 15.4 | 12.5 | 7.8 | 19,800 | 210262459 |
| NCUU49CP4+TDR+TXV | NF80U110T5C-* | 15.4 | 13.0 | 7.8 | 19,900 | 210262448 |
| NCHC42BT5D-**+TDR | NF80L090S4B* | 15.4 | 13.0 | 7.8 | 20,000 | 217490977 |
| NCHC42BT5D-**+TDR | NF80U070S3B* | 15.4 | 13.0 | 7.8 | 20,200 | 217491033 |
| NCUC49CT5D-**+TDR | NF80U090S5C* | 15.4 | 12.5 | 7.8 | 19,800 | 217491075 |
| NCHC42CT5D-**+TDR | NF80X100V5C* | 15.4 | 13.0 | 7.8 | 20,000 | 217491206 |
| NCHC48CT5D-**+TDR | NF80X100V5C* | 15.4 | 13.0 | 7.8 | 20,200 | 217491207 |
| NCUC48CT5D-**+TDR | NF80L110S5C* | 15.4 | 13.0 | 7.8 | 19,600 | 217490985 |
| NCUC49CT5D-**+TDR | NF80L110S5C* | 15.4 | 12.5 | 7.8 | 19,800 | 217490986 |
| NCHC42BT5D-**+TDR | NF80L070S3B* | 15.4 | 13.0 | 7.8 | 20,200 | 217490965 |
| NCUC49CT5D-**+TDR | NF80U110T5C* | 15.4 | 13.0 | 7.8 | 19,900 | 217491125 |
| NCUC48CT5D-**+TDR | NF80U110S5C* | 15.4 | 13.0 | 7.8 | 19,600 | 217491113 |
| NCUC49CT5D-**+TDR | NF80U110S5C* | 15.4 | 12.5 | 7.8 | 19,800 | 217491114 |
| NCHC42BT5D-**+TDR | NF80U090S4B* | 15.4 | 13.0 | 7.8 | 20,000 | 217491066 |
| NCUU49CP4+TDR+TXV | NF97X080V4C-* | 15.2 | 12.5 | 7.8 | 20,000 | 210262454 |
| NCUU49CP4+TDR+TXV | NF96U110S5C-* | 15.2 | 12.5 | 7.8 | 19,900 | 210262452 |
| NCUC49CT4+TDR | NF96U110S5C-* | 15.2 | 12.5 | 7.8 | 19,900 | 210262462 |
| NCUC49CT4+TDR | NF96U090S4C-* | 15.2 | 12.5 | 7.8 | 19,900 | 210262461 |
| NCHC48CT4+TDR | NF80U110T5C-* | 15.2 | 13.0 | 7.8 | 20,200 | 210262455 |
| NCUC49CT4+TDR | NF97X080V4C-* | 15.2 | 12.5 | 7.8 | 20,000 | 210262464 |
| NCHC48CT4+TDR | NF80U110S5C-* | 15.2 | 12.5 | 7.8 | 20,200 | 210262456 |
| NCUU49CP4+TDR+TXV | NF96U090S4C-* | 15.2 | 12.5 | 7.8 | 19,900 | 210262451 |
| NCHC48BT5D-**+TDR | NF80L090S4B* | 15.2 | 13.0 | 7.8 | 20,200 | 217490978 |
| NCHC48CT5D-**+TDR | NF80L110S5C* | 15.2 | 12.5 | 7.8 | 20,200 | 217490984 |
| NCHC48CT5D-**+TDR | NF80U110S5C* | 15.2 | 12.5 | 7.8 | 20,200 | 217491112 |
| NCHC42BT5D-**+TDR | NF95X060S3B* | 15.2 | 12.5 | 7.8 | 20,000 | 217491239 |
| NCUC49CT5D-**+TDR | NF96U110S5C* | 15.2 | 12.5 | 7.8 | 19,900 | 217491342 |
| NCUC49CT5D-**+TDR | NF96U090S4C* | 15.2 | 12.5 | 7.8 | 19,900 | 217491321 |
| NCHC48CT5D-**+TDR | NF80U110T5C* | 15.2 | 13.0 | 7.8 | 20,200 | 217491123 |
| NCUC48BT5D-**+TDR | NF80X080V4B* | 15.2 | 13.0 | 7.8 | 20,000 | 217491195 |
| NCUC48CT5D-**+TDR | NF97X080V4C* | 15.2 | 13.0 | 7.8 | 20,000 | 217491479 |
| NCHC48BT5D-**+TDR | NF80U090S4B* | 15.2 | 13.0 | 7.8 | 20,200 | 217491067 |
| NCUC48CT5D-**+TDR | NF97U090M4C* | 15.2 | 12.5 | 7.8 | 20,000 | 217491421 |
| NCUC49CT5D-**+TDR | NF97X080V4C* | 15.2 | 12.5 | 7.8 | 20,000 | 217491480 |
| NCUC48CT5D-**+TDR | NF80U090S5C* | 15.2 | 12.5 | 7.8 | 20,000 | 217491074 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,482/yr
- Miami, FL$1,231/yr
- Houston, TX$1,327/yr
- Atlanta, GA$1,294/yr
- Los Angeles, CA$1,248/yr
- New York, NY$3,032/yr
- Chicago, IL$2,450/yr
- Denver, CO$2,028/yr
- Seattle, WA$1,239/yr
- Minneapolis, MN$2,506/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS17H42SA4-**A?
- The GE NS17H42SA4-**A is rated at up to 15.6 SEER2 and 13.0 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 52 certified matchups SEER2 ranges from 15.2-15.6.
- Is the GE NS17H42SA4-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
- How much does the GE NS17H42SA4-**A cost to run per year?
- At its rated efficiency it costs about $1,231-$3,032 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,482 in Phoenix and $2,506 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS17H42SA4-**A?
- ENERGY STAR lists 52 certified combinations for this outdoor unit. The highest-rated ones use NAM42V2TA4, NCDC48CT4+TDR, NCDC48CT5D-**+TDR.
- What refrigerant does the GE NS17H42SA4-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Ducane 4HP17L42P-**A15.6 SEER2 · 8.3 HSPF2
- Lennox EL17XP1-042-230A15.6 SEER2 · 8.3 HSPF2
- Comfort-Aire HRG1542S1R-**A15.6 SEER2 · 8.3 HSPF2
- Lennox ML17XP1-042-230A15.6 SEER2 · 8.3 HSPF2
- Blueridge BHP17L42P-**A15.6 SEER2 · 8.3 HSPF2
- MRCOOL MHP17L42P-**A15.6 SEER2 · 8.3 HSPF2
- Armstrong Air 4SHP17LE142P-**A15.6 SEER2 · 8.3 HSPF2
- Hisense AUWR-48U3SP · cold climate15.6 SEER2 · 8.6 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.