HVAC Rated

12,000 BTU mini-split heat pump · 20 Series

Goodman GRXTH12BVJN

Below average cooling efficiency and average heating efficiency for a 12,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #368 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $344 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Below average · beats 12%
HSPF2
10.0 Heating efficiency over a season
Average · beats 43%
EER2
11.3 Cooling efficiency on a 95°F day
Below average · beats 12%
Heat at 5°F
13,000 BTU/h96% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 13,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications12,000 BTU, R-32
General
BrandGoodman
Outdoor unit modelGRXTH12BVJN
Series20 Series
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceAugust 3, 2026
Last certifiedJuly 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 19.5)
EER2Efficiency at 95°F outdoors11.3
Cooling capacity12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0
Capacity at 47°F13,500 BTU/h
Capacity at 17°F11,800 BTU/h
Capacity at 5°F13,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateYes
Heating output as it gets colder96% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with GTXV12BVJN at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
GTXV12BVJN GOODMAN · cold climate19.511.310.013,000218672386
Yearly running cost in 10 large cities$290-$837

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Goodman GRXTH12BVJN?
The Goodman GRXTH12BVJN is rated at up to 19.5 SEER2 and 11.3 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Goodman GRXTH12BVJN good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 13,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Goodman GRXTH12BVJN cost to run per year?
At its rated efficiency it costs about $290-$837 a year in electricity in large U.S. cities, depending on climate and local rates - for example $366 in Phoenix and $706 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Goodman GRXTH12BVJN?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses GOODMAN GTXV12BVJN.
What refrigerant does the Goodman GRXTH12BVJN use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $368/yrYou save $275/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Goodman GRXTH12BVJN
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$368
Current system, per year
$643
You save per year
$275
Payback
16.3 years
Net after 10 years
-$1,745

Cooling $217Heating $151Electricity used: 2,299 kWhSaved vs. a minimum-efficiency heat pump: $129

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.