HVAC Rated

3-ton central heat pump · Connect

Haier 1U36T3PC*HE

Very good cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #49 of 302 3 ton central heat pumps for cooling efficiency, and costs about $974 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
30,000 BTU/h82% of its 47°F output
Below average · beats 27%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 30,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandHaier
Outdoor unit model1U36T3PC*HE
SeriesConnect
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 16, 2024
Last certifiedJanuary 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 15.2-19.0)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity32,200-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.5
Capacity at 47°F34,000-36,000 BTU/h
Capacity at 17°F27,000-29,400 BTU/h
Capacity at 5°F28,200-30,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.95
ENERGY STAR cold climateYes
Heating output as it gets colder82% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM42V2TA5 at the standard test temperatures, in BTU/h:

Certified matchups177 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 177 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
NAM42V2TA5 · cold climate-19.011.79.429,400217270179
NCHC30AT5****+TDR · cold climateNF80U045T3A***18.611.09.028,400217270426
NAM36V2TA5 · cold climate-18.511.09.429,400217270178
NAM36E3TA5 · cold climate-18.511.09.429,400217270223
NAM36E1TA5 · cold climate-18.511.79.030,000217270174
NCUC36AT5****+TDR · cold climateNF80U045T3A***18.511.08.528,600217270403
NCU[C,U]36CT5****+TDR · cold climateNF96U090S3CF***18.510.08.528,600217729283
NCU[C,U]36CT5****+TDR · cold climateNF93U090S3CF***18.410.08.528,400217729284
NAM42V1TA5 · cold climate-18.211.79.030,000217270177
NCHC36CT5****+TDR · cold climateNF98U090M3C***18.211.09.028,400217270466
NCUC30AT5****+TDR · cold climateNF80U045T3A***18.211.08.528,600217270380
NCHC30AT5****+TDR · cold climateNF80U045S3A***18.111.09.028,200217270428
NCHC30AT5****+TDR · cold climateNF80L045S3A***18.111.09.028,200217270429
NCUC36BT5****+TDR · cold climateNF80U090V4B***18.111.78.528,200217270414
NCUC36BT5****+TDR · cold climateNF80U070S3B***18.111.08.528,400217270407
NCUC36BT5****+TDR · cold climateNF80L070S3B***18.111.08.528,400217270408
NCHC30BT5****+TDR · cold climateNF80U090V4B***18.111.78.528,200217270437
NCHC36BT5****+TDR · cold climateNF80U090V4B***18.111.08.528,200217270460
NAM36V1TA5 · cold climate-18.011.79.530,000217269590
NAM42E3TA5 · cold climate-18.012.09.429,000217270224
NCHC36CT5****+TDR · cold climateNF96U090V3C***18.011.09.028,400217270629
NAM42E1TA5 · cold climate-18.011.79.030,000217270176
NCHC36CT5****+TDR · cold climateNF97U090V3C***18.011.09.028,400217270260
NCUC36AT5****+TDR · cold climateNF80U045S3A***18.011.08.528,400217270405
NCUC36AT5****+TDR · cold climateNF80L045S3A***18.011.08.528,400217270406
NCHC30AT5****+TDR · cold climateNF80X040S3A***18.011.09.028,400217270422
NCHC30AT5****+TDR · cold climateNF80X060S3A***18.011.09.028,400217270423
NCHC30AT5****+TDR · cold climateNF80U070S3A***18.011.09.028,200217270427
NCHC36CT5****+TDR · cold climateNF98U090M4C***18.011.09.028,400217270467
NCUC36AT5****+TDR · cold climateNF80X040S3A***18.011.08.528,400217270399
NCHC30BT5****+TDR · cold climateNF80U070S3B***18.011.08.528,400217270430
NCHC30BT5****+TDR · cold climateNF80L070S3B***18.011.08.528,400217270431
NCHC36BT5****+TDR · cold climateNF80U070S3B***18.011.08.528,400217270453
NCHC36BT5****+TDR · cold climateNF80L070S3B***18.011.08.528,400217270454
NCHC36CT5****+TDR · cold climateNF97X080V4C***17.911.09.028,400217270261
NCDC42BT5****+TDR · cold climateNF80D070S3B***17.911.09.028,200217270475
NCUC36AT5****+TDR · cold climateNF80X060S3A***17.911.08.528,400217270400
NCUC36AT5****+TDR · cold climateNF80U070S3A***17.911.08.528,400217270404
NCDC42BT5****+TDR · cold climateNF96D045S3B***17.911.09.028,200217270477
NCU[C,U]36CT5****+TDR · cold climateNF97U110V4CF***17.910.08.528,400217729281
NCUC36BT5****+TDR · cold climateNF98U070M3B***17.811.08.528,200217270409
NCHC30AT5****+TDR · cold climateNF80X060V3A***17.811.09.028,400217270421
NCHC30AT5****+TDR · cold climateNF80L070S3A***17.811.09.028,200217270424
NCHC30AT5****+TDR · cold climateNF80U070T3A***17.811.09.028,200217270425
NCHC30BT5****+TDR · cold climateNF98U070M3B***17.811.08.528,400217270432
NCHC36BT5****+TDR · cold climateNF98U070M3B***17.811.08.528,200217270455
NCUC36BT5****+TDR · cold climateNF97X040V3B***17.711.08.528,400217270248
NCUC30AT5****+TDR · cold climateNF80U045S3A***17.711.08.528,600217270382
NCUC30AT5****+TDR · cold climateNF80L045S3A***17.711.08.528,600217270383
NCUC36AT5****+TDR · cold climateNF80X060V3A***17.711.08.528,400217270398
NCUC36BT5****+TDR · cold climateNF95X060S3B***17.711.08.528,400217270411
NCU[C,U]36CT5****+TDR · cold climateNF98U090M3C***17.710.08.528,400217729276
NCUC30BT5****+TDR · cold climateNF80U070S3B***17.711.08.528,600217270384
NCUC30BT5****+TDR · cold climateNF80L070S3B***17.711.08.528,600217270385
NCUC36AT5****+TDR · cold climateNF80U070T3A***17.711.08.528,400217270402
NCUC36AT5****+TDR · cold climateNF80L070S3A***17.711.08.528,400217270401
NCUC36BT5****+TDR · cold climateNF96U070V3B***17.611.08.528,200217270624
NCUC36BT5****+TDR · cold climateNF97U070V3B***17.611.08.528,200217270251
NCHC30BT5****+TDR · cold climateNF97X040V3B***17.611.08.528,400217270252
NCHC36BT5****+TDR · cold climateNF97X040V3B***17.611.08.528,400217270256
Yearly running cost in 10 large cities$847-$2,347

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Haier 1U36T3PC*HE?
The Haier 1U36T3PC*HE is rated at up to 19.0 SEER2 and 11.7 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 177 certified matchups SEER2 ranges from 15.2-19.0.
Is the Haier 1U36T3PC*HE good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 30,000 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Haier 1U36T3PC*HE cost to run per year?
At its rated efficiency it costs about $847-$2,347 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,056 in Phoenix and $1,969 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Haier 1U36T3PC*HE?
ENERGY STAR lists 177 certified combinations for this outdoor unit. The highest-rated ones use NAM42V2TA5, NCHC30AT5****+TDR, NAM36V2TA5.
What refrigerant does the Haier 1U36T3PC*HE use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,053/yrYou save $733/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Haier 1U36T3PC*HE
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,053
Current system, per year
$1,786
You save per year
$733
Payback
17.7 years
Net after 10 years
-$5,670

Cooling $634Heating $420Electricity used: 6,583 kWhSaved vs. a minimum-efficiency heat pump: $320

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 20, 2026. How we use the data.