3-ton central heat pump · MAINLINE 16 SEER2 HP

Heil B5H6S36*K*AAA

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #267 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,167 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
18,100 BTU/h48% of its 47°F output
Very good · beats 81%

A good fit if…

  • You want a choice of indoor units - 208 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandHeil
Also sold asArcoaire, Airquest, Kenmore, Keeprite, Day & Night, Comfortmaker, Tempstar
Outdoor unit modelB5H6S36*K*AAA
SeriesMAINLINE 16 SEER2 HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity33,800-36,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F33,200-36,200 BTU/h
Capacity at 17°F21,000-22,800 BTU/h
Capacity at 5°F16,700-18,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.24
ENERGY STAR cold climateNo
Heating output as it gets colder48% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FEVA0048**+NAVA54801CK at the standard test temperatures, in BTU/h:

Certified matchups208 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 208 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FEVA0048**+NAVA54801CK-15.512.57.817,400218187424
FMA5X36**AL-15.512.57.817,000218187420
FEVB0048**+NAVA54801CK-15.512.57.817,400218187418
FEVA0048**+NAVA54801CK-15.512.57.817,400218193510
FEVA0048**+NAVA54801CK-15.512.57.817,400218193507
F5MA5*48L*C-15.513.07.817,500218193504
F5MA5*48L*C-15.513.07.817,500218193503
F5MA5*48L*C-15.513.07.817,500218193500
FMA5X36**AL-15.512.57.817,000218192801
FMA5X36**AL-15.512.57.817,000218192800
FEVB0048**+NAVA54801CK-15.512.57.817,400218192791
FEVB0048**+NAVA54801CK-15.512.57.817,400218192790
FHMA5*48L*C-15.513.07.817,500218192497
FHMA5*48L*C-15.513.07.817,500218192494
FHMA5*48L*C-15.513.07.817,500218192493
FTMA5B48L0C-15.512.57.816,700218192486
FTMA5B48L0C-15.512.57.816,700218192485
FTMA5B48L0C-15.512.57.816,700218192484
FMA5X36**AL-15.512.57.817,000218198296
FEVB0048**+NAVA54801CK-15.512.57.817,400218198294
FHMA5*48L*C-15.513.07.817,500218198233
FTMA5B48L0C-15.512.57.816,700218198232
FEVA0048**+NAVA54801CK-15.512.57.817,400218198413
F5MA5*48L*C-15.513.07.817,500218198412
FHMA5*48L*C-15.513.07.817,500218208030
FHMA5*48L*C-15.513.07.817,500218208029
FHMA5*48L*C-15.513.07.817,500218208028
FTMA5B48L0C-15.512.57.816,700218208027
FTMA5B48L0C-15.512.57.816,700218208026
FTMA5B48L0C-15.512.57.816,700218208025
FEVB0048**+NAVA54801CK-15.512.57.817,400218208021
FEVA0048**+NAVA54801CK-15.512.57.817,400218208569
FEVA0048**+NAVA54801CK-15.512.57.817,400218208568
FEVA0048**+NAVA54801CK-15.512.57.817,400218208567
F5MA5*48L*C-15.513.07.817,500218208566
F5MA5*48L*C-15.513.07.817,500218208565
F5MA5*48L*C-15.513.07.817,500218208564
FMA5X36**AL-15.512.57.817,000218208218
FMA5X36**AL-15.512.57.817,000218208217
FMA5X36**AL-15.512.57.817,000218208216
FEVB0048**+NAVA54801CK-15.512.57.817,400218208212
FEVB0048**+NAVA54801CK-15.512.57.817,400218208211
FEVA0048**+NAVA54801CK-15.512.57.817,400218209615
F5MA5*48L*C-15.513.07.817,500218209614
FMA5X36**AL-15.512.57.817,000218209498
FEVB0048**+NAVA54801CK-15.512.57.817,400218209496
FHMA5*48L*C-15.513.07.817,500218209435
FTMA5B48L0C-15.512.57.816,700218209434
FM(C,U)5Z36**AL-15.212.57.817,200218187423
EA*5X48M21A*96CTN0802120B*15.212.07.817,500218187347
EA*5X48M21A*80CTL1102120B*15.212.07.817,500218187344
EA*5X48M21A*96VTN1002122B*15.211.77.817,500218191391
EA*5X48M21A*96VTN1002122B*15.211.77.817,500218191390
EA*5X48M21A*96VTN1002122B*15.211.77.817,500218191389
EA*5X48M21A*96CTN0802120B*15.212.07.817,500218191383
EA*5X48M21A*96CTN0802120B*15.212.07.817,500218191382
EA*5X48M21A*95MSU1002122A*15.212.07.817,600218191381
EA*5X48M21A*95MSU1002122A*15.212.07.817,600218191380
EA*5X48M21A*95MSU1002122A*15.212.07.817,600218191379
EA*5X48M21A*92MSN1002120A*15.212.07.817,600218191363
Yearly running cost in 10 large cities$1,054-$2,779

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil B5H6S36*K*AAA?
The Heil B5H6S36*K*AAA is rated at up to 15.5 SEER2 and 12.5 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 208 certified matchups SEER2 ranges from 15.2-15.5.
Is the Heil B5H6S36*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Heil B5H6S36*K*AAA cost to run per year?
At its rated efficiency it costs about $1,054-$2,779 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,294 in Phoenix and $2,318 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil B5H6S36*K*AAA?
ENERGY STAR lists 208 certified combinations for this outdoor unit. The highest-rated ones use FEVA0048**+NAVA54801CK, FMA5X36**AL, FEVB0048**+NAVA54801CK.
What refrigerant does the Heil B5H6S36*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,281/yrYou save $503/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil B5H6S36*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,281
Current system, per year
$1,785
You save per year
$503
Payback
25.8 years
Net after 10 years
-$7,968

Cooling $790Heating $491Electricity used: 8,009 kWhSaved vs. a minimum-efficiency heat pump: $86

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.