36,000 BTU mini-split heat pump · Hi UNI
Hisense AUW-36U3TW1(JCH)
Below average cooling efficiency and average heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #152 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $949 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonBelow average · beats 18%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 12.0 Cooling efficiency on a 95°F dayBelow average · beats 25%
- Heat at 5°F
- 36,000 BTU/h100% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 36,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Hisense |
| Outdoor unit model | AUW-36U3TW1(JCH) |
| Series | Hi UNI |
| Type | Mini-split heat pump |
| Nominal size | 36,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | August 14, 2024 |
| Last certified | May 1, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 15.2-20.0) |
| EER2Efficiency at 95°F outdoors | 11.0-12.0 |
| Cooling capacity | 33,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-10.0 |
| Capacity at 47°F | 34,000-36,000 BTU/h |
| Capacity at 17°F | 25,600-27,000 BTU/h |
| Capacity at 5°F | 36,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AS-36UW3TWHTU00 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| AS-36UW3TWHTU00 HISENSE · cold climate | 20.0 | 12.0 | 10.0 | 36,000 | 216021122 |
| AUC-36UR3TKA1(JCH) HISENSE · cold climate | 19.5 | 12.0 | 9.5 | 36,000 | 215441420 |
| AUD-36UX3TEH1(JCH ) HISENSE · cold climate | 18.5 | 11.7 | 9.0 | 36,000 | 215441403 |
| DC37D3J · cold climate | 15.2 | 11.0 | 9.0 | 36,000 | 218156600 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,044/yr
- Miami, FL$846/yr
- Houston, TX$936/yr
- Atlanta, GA$949/yr
- Los Angeles, CA$924/yr
- New York, NY$2,272/yr
- Chicago, IL$1,845/yr
- Denver, CO$1,534/yr
- Seattle, WA$943/yr
- Minneapolis, MN$1,899/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hisense AUW-36U3TW1(JCH)?
- The Hisense AUW-36U3TW1(JCH) is rated at up to 20.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 15.2-20.0.
- Is the Hisense AUW-36U3TW1(JCH) good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 36,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Hisense AUW-36U3TW1(JCH) cost to run per year?
- At its rated efficiency it costs about $846-$2,272 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,044 in Phoenix and $1,899 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Hisense AUW-36U3TW1(JCH)?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use HISENSE AS-36UW3TWHTU00, HISENSE AUC-36UR3TKA1(JCH), HISENSE AUD-36UX3TEH1(JCH ).
- What refrigerant does the Hisense AUW-36U3TW1(JCH) use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 36,000 BTU models
- Mitsubishi Electric PUZ-HA36NKA · cold climate20.0 SEER2 · 10.0 HSPF2
- Guardian UPC36CN23STG1 · cold climate20.0 SEER2 · 10.0 HSPF2
- Mitsubishi Electric PUZ-HA36NKA1 · cold climate20.0 SEER2 · 10.0 HSPF2
- ComfortStar C32-MZ-5 · cold climate20.0 SEER2 · 10.0 HSPF2
- Mitsutomo HO-MQ36-AB-Q · cold climate20.0 SEER2 · 10.0 HSPF2
- Blueridge BMM36HHC · cold climate20.0 SEER2 · 10.0 HSPF2
- Trane / Mitsubishi Electric TRUZH0361KA00NA · cold climate20.0 SEER2 · 10.0 HSPF2
- Airquest DLCMHBH36DAK · cold climate20.0 SEER2 · 10.0 HSPF2
See all 205 36,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.