HVAC Rated

42,000 BTU mini-split heat pump · Hi UNI

Hisense AUW-48U3TH1(JCH)

Below average cooling and heating efficiency for a 42,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #47 of 61 42,000 BTU mini-splits for cooling efficiency, and costs about $1,199 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Below average · beats 18%
HSPF2
9.5 Heating efficiency over a season
Below average · beats 24%
EER2
12.0 Cooling efficiency on a 95°F day
Below average · beats 25%
Heat at 5°F
44,000 BTU/h100% of its 47°F output
Average · beats 48%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 44,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications42,000 BTU, R-454B
General
BrandHisense
Outdoor unit modelAUW-48U3TH1(JCH)
SeriesHi UNI
TypeMini-split heat pump
Nominal size42,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 29, 2024
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 15.2-20.0)
EER2Efficiency at 95°F outdoors10.7-12.0
Cooling capacity44,000-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.5
Capacity at 47°F44,000-48,000 BTU/h
Capacity at 17°F28,600-38,000 BTU/h
Capacity at 5°F42,000-44,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AUC-48UR3TKA1(JCH) at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
AUC-48UR3TKA1(JCH) HISENSE · cold climate20.012.09.544,000215441419
AUD-48UX3TEH1(JCH ) HISENSE · cold climate19.510.79.544,000215441402
DC49B3J · cold climate15.211.08.542,000218156601
Yearly running cost in 10 large cities$1,036-$2,895

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Hisense AUW-48U3TH1(JCH)?
The Hisense AUW-48U3TH1(JCH) is rated at up to 20.0 SEER2 and 12.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 15.2-20.0.
Is the Hisense AUW-48U3TH1(JCH) good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 44,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Hisense AUW-48U3TH1(JCH) cost to run per year?
At its rated efficiency it costs about $1,036-$2,895 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,294 in Phoenix and $2,432 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Hisense AUW-48U3TH1(JCH)?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use HISENSE AUC-48UR3TKA1(JCH), HISENSE AUD-48UX3TEH1(JCH ), DC49B3J.
What refrigerant does the Hisense AUW-48U3TH1(JCH) use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,293/yrYou save $976/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Hisense AUW-48U3TH1(JCH)
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,293
Current system, per year
$2,269
You save per year
$976
Payback
16.9 years
Net after 10 years
-$6,744

Cooling $774Heating $519Electricity used: 8,082 kWhSaved vs. a minimum-efficiency heat pump: $447

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 42,000 BTU models

See all 61 42,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.