HVAC Rated

2-ton central heat pump · Hi-PRO HD

Hisense AUWR-2424P

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #23 of 331 2 ton central heat pumps for cooling efficiency, and costs about $633 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
21,000 BTU/h87% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandHisense
Outdoor unit modelAUWR-2424P
SeriesHi-PRO HD
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 1, 2024
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 16.0-20.0)
EER2Efficiency at 95°F outdoors11.2-12.0
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.2-10.0
Capacity at 47°F24,000 BTU/h
Capacity at 17°F17,000-20,400 BTU/h
Capacity at 5°F20,800-21,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.95-2.30
ENERGY STAR cold climateYes
Heating output as it gets colder87% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AUH-2424 at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
AUH-2424 · cold climate20.012.010.020,800214855377
AHU-24U3T24 · cold climate20.012.010.020,800217619860
DC31D2J · cold climate16.011.28.221,000217178838
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Hisense AUWR-2424P: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$564-$1,514

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Hisense AUWR-2424P?
The Hisense AUWR-2424P is rated at up to 20.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 16.0-20.0.
Is the Hisense AUWR-2424P good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,000 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the Hisense AUWR-2424P cost to run per year?
At its rated efficiency it costs about $564-$1,514 a year in electricity in large U.S. cities, depending on climate and local rates - for example $696 in Phoenix and $1,266 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Hisense AUWR-2424P the same as the Hisense AOH-24U3T24P?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Hisense AUWR-2424P?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use AUH-2424, AHU-24U3T24, DC31D2J.
What refrigerant does the Hisense AUWR-2424P use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $691/yrYou save $546/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Hisense AUWR-2424P
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$691
Current system, per year
$1,238
You save per year
$546
Payback
16.5 years
Net after 10 years
-$3,537

Cooling $422Heating $269Electricity used: 4,320 kWhSaved vs. a minimum-efficiency heat pump: $258

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.