9,000 BTU mini-split heat pump · airCore700
Hitachi PAS-09BUFASDQ1-LAC
Very good cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #214 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $211 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.5 Cooling efficiency over a seasonVery good · beats 70%
- HSPF2
- 11.0 Heating efficiency over a seasonVery good · beats 75%
- EER2
- 15.0 Cooling efficiency on a 95°F dayExcellent · beats 91%
- Heat at 5°F
- 10,000 BTU/h111% of its 47°F outputVery good · beats 76%
A good fit if…
- You want low cooling bills - its SEER2 beats 70% of mini-splits.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 10,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 75% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Hitachi |
| Outdoor unit model | PAS-09BUFASDQ1-LAC |
| Series | airCore700 |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | May 13, 2025 |
| Last certified | March 26, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.5 (range 20.0-23.5) |
| EER2Efficiency at 95°F outdoors | 13.0-15.0 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.5-11.0 |
| Capacity at 47°F | 9,000 BTU/h |
| Capacity at 17°F | 9,900-10,500 BTU/h |
| Capacity at 5°F | 9,000-10,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.18 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with PCIM-B09UFA1DQ at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| PCIM-B09UFA1DQ HITACHI · cold climate | 23.5 | 15.0 | 11.0 | 10,000 | 217450774 |
| PPFC-B09UFA1DQ HITACHI · cold climate | 23.0 | 15.0 | 9.5 | 9,900 | 217450767 |
| PPK-B09UFA1DQ HITACHI · cold climate | 22.0 | 15.0 | 10.0 | 9,000 | 217450735 |
| PPIM-B09UFA1DQ HITACHI · cold climate | 20.0 | 13.0 | 9.6 | 9,600 | 217450750 |
Yearly running cost in 10 large cities
- Phoenix, AZ$226/yr
- Miami, FL$180/yr
- Houston, TX$203/yr
- Atlanta, GA$211/yr
- Los Angeles, CA$206/yr
- New York, NY$510/yr
- Chicago, IL$415/yr
- Denver, CO$346/yr
- Seattle, WA$214/yr
- Minneapolis, MN$429/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Hitachi PAS-09BUFASDQ1-LAC?
- The Hitachi PAS-09BUFASDQ1-LAC is rated at up to 23.5 SEER2 and 15.0 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 20.0-23.5.
- Is the Hitachi PAS-09BUFASDQ1-LAC good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 10,000 BTU/h at 5°F with a COP of 2.18, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
- How much does the Hitachi PAS-09BUFASDQ1-LAC cost to run per year?
- At its rated efficiency it costs about $180-$510 a year in electricity in large U.S. cities, depending on climate and local rates - for example $226 in Phoenix and $429 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Hitachi PAS-09BUFASDQ1-LAC?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use HITACHI PCIM-B09UFA1DQ, HITACHI PPFC-B09UFA1DQ, HITACHI PPK-B09UFA1DQ.
- What refrigerant does the Hitachi PAS-09BUFASDQ1-LAC use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- Fujitsu AOUH09LUAS1 · cold climate23.5 SEER2 · 11.8 HSPF2
- GE Appliances ASH109PRDB · cold climate23.5 SEER2 · 9.6 HSPF2
- MRCOOL DIY-09-HP-C-115D25-O · cold climate23.6 SEER2 · 11.5 HSPF2
- GE Appliances ASH109PRDWA23.5 SEER2 · 9.5 HSPF2
- LG KUSAB091A · cold climate23.8 SEER2 · 10.9 HSPF2
- RunTru M3THS2209A91NA23.5 SEER2 · 9.5 HSPF2
- Mitsubishi Electric SUZ-KA09NAH224.0 SEER2 · 9.0 HSPF2
- TCL TSH09HDI1NAN0T2323.5 SEER2 · 9.5 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 26, 2026. How we use the data.