48,000 BTU mini-split heat pump · M series
Lennox MPC048S4M-1P
Average cooling efficiency and below average heating efficiency for a 48,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #19 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,316 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.4 Cooling efficiency over a seasonAverage · beats 68%
- HSPF2
- 8.7 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 12.3 Cooling efficiency on a 95°F dayBelow average · beats 35%
- Heat at 5°F
- 33,000 BTU/h69% of its 47°F outputBelow average · beats 9%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Outdoor unit model | MPC048S4M-1P |
| Series | M series |
| Type | Mini-split heat pump |
| Nominal size | 48,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 18, 2019 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.4 (range 23.4) |
| EER2Efficiency at 95°F outdoors | 12.3 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.7 |
| Capacity at 47°F | 48,000 BTU/h |
| Capacity at 17°F | 34,000 BTU/h |
| Capacity at 5°F | 33,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - LENNOX | 23.4 | 12.3 | 8.7 | 33,000 | 207699101 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,299/yr
- Miami, FL$975/yr
- Houston, TX$1,169/yr
- Atlanta, GA$1,316/yr
- Los Angeles, CA$1,311/yr
- New York, NY$3,311/yr
- Chicago, IL$2,720/yr
- Denver, CO$2,287/yr
- Seattle, WA$1,425/yr
- Minneapolis, MN$2,841/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox MPC048S4M-1P?
- The Lennox MPC048S4M-1P is rated at up to 23.4 SEER2 and 12.3 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Lennox MPC048S4M-1P good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 48,000 BTU model.
- How much does the Lennox MPC048S4M-1P cost to run per year?
- At its rated efficiency it costs about $975-$3,311 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,299 in Phoenix and $2,841 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Lennox MPC048S4M-1P use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 48,000 BTU models
- Midea MMCMRAQ48EA323.4 SEER2 · 9.2 HSPF2
- MRCOOL MULTI5-48HP230B23.4 SEER2 · 8.7 HSPF2
- MDV M5OG-48HFN1-M-L23.4 SEER2 · 9.2 HSPF2
- LG ZRUM048GSS0 · cold climate23.3 SEER2 · 10.3 HSPF2
- Cooper&Hunter CH-48MES-230VO23.4 SEER2 · 9.2 HSPF2
- York YVAHP048B21S23.1 SEER2 · 10.0 HSPF2
- Carrier 38MGRBQ48EA323.4 SEER2 · 9.2 HSPF2
- Mitsubishi Electric MXZ-SM48NAMHZ2 · cold climate23.0 SEER2 · 11.5 HSPF2
See all 146 48,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 25, 2026. How we use the data.