HVAC Rated

24,000 BTU mini-split heat pump · KUMXB241A

LG KUMXB241A

Average cooling efficiency and below average heating efficiency for a 24,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #137 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $603 a year to run in a mixed climate like Atlanta.

SEER2
22.5 Cooling efficiency over a season
Average · beats 56%
HSPF2
9.8 Heating efficiency over a season
Below average · beats 33%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
17,300 BTU/h70% of its 47°F output
Very good · beats 86%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-32
General
BrandLG
Outdoor unit modelKUMXB241A
SeriesKUMXB241A
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceJune 26, 2024
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better22.5 (range 18.5-22.5)
EER2Efficiency at 95°F outdoors12.5
Cooling capacity22,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-9.8
Capacity at 47°F23,000-24,600 BTU/h
Capacity at 17°F15,000-15,300 BTU/h
Capacity at 5°F16,800-17,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
-22.512.59.817,300214848483
-20.512.59.417,000214848486
-18.512.59.016,800214848484
Yearly running cost in 10 large cities$483-$1,486

At each state's average electricity price and the city's typical heating and cooling hours.

Questions4
What is the SEER2 rating of the LG KUMXB241A?
The LG KUMXB241A is rated at up to 22.5 SEER2 and 12.5 EER2 for cooling and up to 9.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 18.5-22.5.
Is the LG KUMXB241A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 24,000 BTU model.
How much does the LG KUMXB241A cost to run per year?
At its rated efficiency it costs about $483-$1,486 a year in electricity in large U.S. cities, depending on climate and local rates - for example $623 in Phoenix and $1,262 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
What refrigerant does the LG KUMXB241A use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $632/yrYou save $567/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump LG KUMXB241A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$632
Current system, per year
$1,199
You save per year
$567
Payback
15.0 years
Net after 10 years
-$2,828

Cooling $360Heating $272Electricity used: 3,949 kWhSaved vs. a minimum-efficiency heat pump: $290

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.