HVAC Rated

3-ton central heat pump · MAU Series

Midea MO1BE-H36B-2A

Average cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #189 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,064 a year to run in a mixed climate like Atlanta.

SEER2
16.7 Cooling efficiency over a season
Average · beats 43%
HSPF2
9.3 Heating efficiency over a season
Average · beats 62%
EER2
10.2 Cooling efficiency on a 95°F day
Below average · beats 15%
Heat at 5°F
29,200 BTU/h79% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 29,200 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 29 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandMidea
Outdoor unit modelMO1BE-H36B-2A
SeriesMAU Series
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceSeptember 5, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.7 (range 15.2-16.7)
EER2Efficiency at 95°F outdoors9.2-10.2
Cooling capacity35,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.3
Capacity at 47°F35,000-37,000 BTU/h
Capacity at 17°F23,000-27,000 BTU/h
Capacity at 5°F26,000-29,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder79% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MAWHE-H36B-2A at the standard test temperatures, in BTU/h:

Certified matchups29 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
MAWHE-H36B-2A · cold climate-16.710.29.329,200216607260
MAUHE-H36B-2A · cold climate-16.110.08.727,000215471328
MAAHE-H36B-CA-UC · cold climateRL18100C20MPS115.710.18.526,000218156254
MAAHE-H36B-CA · cold climateRL18100C20MPS115.710.18.526,000218155496
MAAHE-H36B-CA-UC · cold climateS9V2C100U5VS***15.69.98.526,000218156042
MAAHE-H36B-CA-UC · cold climateS9V2C100D5VS***15.69.98.526,000218156041
MAAHE-H36B-CA · cold climateS9V2C100U5VS***15.69.98.526,000218155284
MAAHE-H36B-CA · cold climateS9V2C100D5VS***15.69.98.526,000218155283
MAAHE-H36B-CA-UC · cold climateRL18100C16MPS115.610.08.426,000218156253
MAAHE-H36B-CA · cold climateRL18100C16MPS115.610.08.426,000218155495
MAAHE-H36B-CA-UC · cold climateRL18080C16MPS115.69.68.326,000218156252
MAAHE-H36B-CA · cold climateRL18080C16MPS115.69.68.326,000218155494
MAAHE-H36B-CA-UC · cold climateML296UH110XV60C*15.59.98.526,000218156469
MAAHE-H36B-CA · cold climateML296UH110XV60C*15.59.98.526,000218155711
MAPHE-H36B-2A · cold climate-15.49.28.728,400216623532
MAAHE-H36B-BA · cold climateMGV96U060B3C15.49.58.226,000217608547
MAAHE-H36B-BA-UC · cold climateRL18080B12MPS115.49.38.226,000218156251
MAAHE-H36B-BA-UC · cold climateMGV96U060B3C15.49.58.226,000218155868
MAAHE-H36B-BA · cold climateRL18080B12MPS115.49.38.226,000218155493
MAAHE-H36B-BA-UC · cold climateBZ33-96E2U060B315.49.58.226,000218396938
MAAHE-H36B-BA · cold climateBZ33-96E2U060B315.49.58.226,000218396891
MAAHE-H36B-BA-UC · cold climateW962V060BU3SAA15.49.58.226,000218466453
MAAHE-H36B-BA · cold climateW962V060BU3SAA15.49.58.226,000218466343
MAAHE-H36B-CA-UC · cold climateRG19080C16MPS115.49.58.126,000218156197
MAAHE-H36B-CA · cold climateRG19080C16MPS115.49.58.126,000218155439
MAAHE-H36B-CA-UC · cold climateS9V2C080U5VS***15.39.88.626,000218156040
MAAHE-H36B-CA · cold climateS9V2C080U5VS***15.39.88.626,000218155282
MAAHE-H36B-BA-UC · cold climateRG19080B12MPS115.29.38.427,000218156196
MAAHE-H36B-BA · cold climateRG19080B12MPS115.29.38.427,000218155438
Yearly running cost in 10 large cities$1,010-$2,496

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Midea MO1BE-H36B-2A?
The Midea MO1BE-H36B-2A is rated at up to 16.7 SEER2 and 10.2 EER2 for cooling and up to 9.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 29 certified matchups SEER2 ranges from 15.2-16.7.
Is the Midea MO1BE-H36B-2A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 29,200 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Midea MO1BE-H36B-2A cost to run per year?
At its rated efficiency it costs about $1,010-$2,496 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,217 in Phoenix and $2,063 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Midea MO1BE-H36B-2A?
ENERGY STAR lists 29 certified combinations for this outdoor unit. The highest-rated ones use MAWHE-H36B-2A, MAUHE-H36B-2A, MAAHE-H36B-CA-UC.
What refrigerant does the Midea MO1BE-H36B-2A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,192/yrYou save $664/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Midea MO1BE-H36B-2A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,192
Current system, per year
$1,856
You save per year
$664
Payback
20.3 years
Net after 10 years
-$6,861

Cooling $759Heating $434Electricity used: 7,452 kWhSaved vs. a minimum-efficiency heat pump: $231

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.