HVAC Rated

12,000 BTU mini-split heat pump · VoxIn 21S

TCL H12SVH20BQC

Below average cooling and heating efficiency for a 12,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #342 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $346 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Below average · beats 30%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 2%
EER2
11.1 Cooling efficiency on a 95°F day
Below average · beats 11%
Heat at 5°F
8,400 BTU/h70% of its 47°F output
Below average · beats 9%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications12,000 BTU, R-32
General
BrandTCL
Outdoor unit modelH12SVH20BQC
SeriesVoxIn 21S
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceJune 10, 2025
Last certifiedMarch 26, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 21.0)
EER2Efficiency at 95°F outdoors11.1
Cooling capacity12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5
Capacity at 47°F12,000 BTU/h
Capacity at 17°F9,000 BTU/h
Capacity at 5°F8,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateNo
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with H12SVH20BQE at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
H12SVH20BQE21.011.18.58,400218330346
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the TCL H12SVH20BQC: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

  • TCL TSH12HDI1NAL0B25
Yearly running cost in 10 large cities$271-$858

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the TCL H12SVH20BQC?
The TCL H12SVH20BQC is rated at up to 21.0 SEER2 and 11.1 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the TCL H12SVH20BQC good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 12,000 BTU model.
How much does the TCL H12SVH20BQC cost to run per year?
At its rated efficiency it costs about $271-$858 a year in electricity in large U.S. cities, depending on climate and local rates - for example $352 in Phoenix and $732 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the TCL H12SVH20BQC the same as the TCL TSH12HDI1NAL0B25?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the TCL H12SVH20BQC?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses H12SVH20BQE.
What refrigerant does the TCL H12SVH20BQC use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $359/yrYou save $259/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TCL H12SVH20BQC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$359
Current system, per year
$619
You save per year
$259
Payback
17.3 years
Net after 10 years
-$1,905

Cooling $201Heating $158Electricity used: 2,245 kWhSaved vs. a minimum-efficiency heat pump: $115

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 26, 2026. How we use the data.