HVAC Rated

9,000 BTU mini-split heat pump · T-Pro-24ES

TCL TSH09HEI2NAO0T24

Average cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #224 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $231 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Average · beats 62%
HSPF2
10.5 Heating efficiency over a season
Average · beats 61%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
7,400 BTU/h78% of its 47°F output
Below average · beats 34%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 7,400 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications9,000 BTU, R-454B
General
BrandTCL
Also sold asDELLA
Outdoor unit modelTSH09HEI2NAO0T24
SeriesT-Pro-24ES
TypeMini-split heat pump
Nominal size9,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 25, 2024
Last certifiedJune 9, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 19.6-23.0)
EER2Efficiency at 95°F outdoors12.0-13.0
Cooling capacity9,000-9,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5-10.5
Capacity at 47°F9,500-10,000 BTU/h
Capacity at 17°F8,000-8,500 BTU/h
Capacity at 5°F7,100-7,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.85-1.95
ENERGY STAR cold climateYes
Heating output as it gets colder78% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCH09IEI2NAC24 at the standard test temperatures, in BTU/h:

Certified matchups4 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
TCH09IEI2NAC24 · cold climate23.012.510.57,400216706231
TSH09IEI2NAO0T24 · cold climate23.013.09.57,100215222836
- · cold climate19.612.010.07,400216706243
TDH09IEI2NAD24 · cold climate19.612.010.07,400218471403
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the TCL TSH09HEI2NAO0T24: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

  • DELLA 048-TP-9K2V-24S-OUT
Yearly running cost in 10 large cities$195-$561

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the TCL TSH09HEI2NAO0T24?
The TCL TSH09HEI2NAO0T24 is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 19.6-23.0.
Is the TCL TSH09HEI2NAO0T24 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 7,400 BTU/h at 5°F with a COP of 1.95, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the TCL TSH09HEI2NAO0T24 cost to run per year?
At its rated efficiency it costs about $195-$561 a year in electricity in large U.S. cities, depending on climate and local rates - for example $246 in Phoenix and $473 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the TCL TSH09HEI2NAO0T24 the same as the DELLA 048-TP-9K2V-24S-OUT?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the TCL TSH09HEI2NAO0T24?
ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use TCH09IEI2NAC24, TSH09IEI2NAO0T24, TDH09IEI2NAD24.
What refrigerant does the TCL TSH09HEI2NAO0T24 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $247/yrYou save $243/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TCL TSH09HEI2NAO0T24
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$247
Current system, per year
$490
You save per year
$243
Payback
14.4 years
Net after 10 years
-$1,069

Cooling $145Heating $101Electricity used: 1,542 kWhSaved vs. a minimum-efficiency heat pump: $129

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 9,000 BTU models

See all 395 9,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.