HVAC Rated

2-ton central heat pump · G Series

TOSOT TUD30-24W2/NHG-D(U)

Very good cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #132 of 331 2 ton central heat pumps for cooling efficiency, and costs about $830 a year to run in a mixed climate like Atlanta.

SEER2
18.2 Cooling efficiency over a season
Very good · beats 73%
HSPF2
8.3 Heating efficiency over a season
Below average · beats 30%
EER2
11.2 Cooling efficiency on a 95°F day
Below average · beats 28%
Heat at 5°F
19,500 BTU/h79% of its 47°F output
Average · beats 67%

A good fit if…

  • You want low cooling bills - its SEER2 beats 73% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-32
General
BrandTOSOT
Also sold asGREE, Kinghome, BOREAL, AIR-CON
Outdoor unit modelTUD30-24W2/NHG-D(U)
SeriesG Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceMarch 17, 2026
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.2 (range 17.5-18.2)
EER2Efficiency at 95°F outdoors11.2
Cooling capacity24,000-27,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.3
Capacity at 47°F24,000-27,000 BTU/h
Capacity at 17°F19,600-23,000 BTU/h
Capacity at 5°F19,000-19,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-2.14
ENERGY STAR cold climateNo
Heating output as it gets colder79% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TUD24AH2/NHG-D(U) at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
TUD24AH2/NHG-D(U)18.211.28.319,000218330465
TUD30AH2/NHG-D(U)17.511.28.319,500218330464
Same unit, other model numbers5

These model numbers have exactly the same certified ratings and matchups as the TOSOT TUD30-24W2/NHG-D(U): the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$699-$2,018

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the TOSOT TUD30-24W2/NHG-D(U)?
The TOSOT TUD30-24W2/NHG-D(U) is rated at up to 18.2 SEER2 and 11.2 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 17.5-18.2.
Is the TOSOT TUD30-24W2/NHG-D(U) good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the TOSOT TUD30-24W2/NHG-D(U) cost to run per year?
At its rated efficiency it costs about $699-$2,018 a year in electricity in large U.S. cities, depending on climate and local rates - for example $883 in Phoenix and $1,702 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the TOSOT TUD30-24W2/NHG-D(U) the same as the GREE GUD30W2/NHG-D(U)?
Yes, as far as the certified ratings go. ENERGY STAR lists 6 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the TOSOT TUD30-24W2/NHG-D(U)?
ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use TUD24AH2/NHG-D(U), TUD30AH2/NHG-D(U).
What refrigerant does the TOSOT TUD30-24W2/NHG-D(U) use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $887/yrYou save $506/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TOSOT TUD30-24W2/NHG-D(U)
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$887
Current system, per year
$1,392
You save per year
$506
Payback
19.8 years
Net after 10 years
-$4,943

Cooling $522Heating $364Electricity used: 5,541 kWhSaved vs. a minimum-efficiency heat pump: $181

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.