HVAC Rated

2-ton central heat pump · 15 Single-Stage Heat Pump with WeatherGuard Top

Trane 5TWX5024A1

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #268 of 331 2 ton central heat pumps for cooling efficiency, and costs about $729 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
11,700 BTU/h51% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 75 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX5024A1
Series15 Single-Stage Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 1, 2024
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity21,200-25,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F20,600-23,000 BTU/h
Capacity at 17°F13,700-15,200 BTU/h
Capacity at 5°F10,600-11,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TEMCD06AV41+TDR+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups75 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 75 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TEMCD06AV41+TDR+TSTAT-16.512.08.011,000215863968
5TEMCD07AV51+TDR+TSTAT-16.512.07.811,000215863969
5TEM6D04AV31+TDR+TSTAT-16.012.08.111,600214181742
5TEM6D06AV41+TDR+TSTAT-16.012.08.111,500214181744
5TXCB006AS3+TSTATS9X1B060U4PSB16.012.08.111,400214181988
5TXCB006AS3+TSTATS9X2B060U4PSB16.012.08.111,400214181990
5TXCC007AS3+TSTAT*UHMC100CCV416.012.08.111,100214182007
5TEM6D05AV41+TDR+TSTAT-16.012.08.111,600215610970
5TEMCD04AV31+TDR+TSTAT-16.012.08.111,100215863966
5TEMCD05AV41+TDR+TSTAT-16.012.08.111,100215863967
5TEM4B04AC31+TDR+TSTAT-16.012.08.011,400218154619
5TXCB006AS3+TSTATS8V2B080M4PCA16.012.07.811,100214181923
5TXCB006AS3+TSTATS8V2B080M4PDA16.012.07.811,100214181935
5TXCB006AS3+TSTATS8X1B060M4PSC16.012.07.811,300214181939
5TXCB006AS3+TSTATS8X1B060M4PTC16.012.07.811,300214181941
5TXCB006AS3+TSTATS8X1B080M4PSC16.012.07.811,400214181943
5TXCB006AS3+TSTATS8X1B080M4PTC16.012.07.811,400214181946
5TXCB006AS3+TSTATS8X2B060M4PSC16.012.07.811,300214181948
5TXCB006AS3+TSTATS8X2B060M4PTC16.012.07.811,300214181950
5TXCB006AS3+TSTATS8X2B080M4PSC16.012.07.811,400214181952
5TXCB006AS3+TSTATS8X2B080M4PTC16.012.07.811,400214181954
5TXCB006AS3+TSTATS9V2B060U3VSA16.012.07.811,100214181970
5TXCB004AS3+TSTATL9X1A050U3VSA16.011.77.810,600214181915
5TXCB006AS3+TSTATS8V2A040M3PCB16.012.07.810,800214181999
5TXCB006AS3+TSTATS8V2A040M3PDB16.012.07.810,800214181995
5TXCB006AS3+TSTAT*UHMB060CCV316.012.07.811,000214181927
5TEM6B03AV21+TDR+TSTAT-15.512.08.111,700214181740
5TXCB006AS3+TSTATS9V2B080U4VSA15.512.08.111,300214181980
5TXCB004AS3+TSTATS9X1B080U4PSB15.512.08.111,200214181902
5TXCB004AS3+TSTATS9X2B080U4PSB15.512.08.111,200214181913
5TXCB006AS3+TSTAT*UHMB080CCV315.512.08.111,100214181931
5TXCB006AS3+TSTATS9V2B040U3PSC15.512.08.111,300214181964
5TXCB006AS3+TSTATS9V2B040U3VSB15.512.08.111,300214181968
5TXCB006AS3+TSTATS9V2B060U4PSC15.512.08.111,300214181974
5TXCB006AS3+TSTATS9V2B080U4PSC15.512.08.111,300214181978
5TXCB006AS3+TSTATS8V2B060M4PCA15.512.07.811,100214181919
5TXCB006AS3+TSTATS8V2B060M4PDB15.512.07.811,100214181921
5TXCB006AS3+TSTAT*UHMB060ACV315.512.07.810,900214181925
5TXCB006AS3+TSTATL8V1B080U4VSB15.512.07.811,200214181962
5TXCB006AS3+TSTATS8V2B060M4PDA15.512.07.811,100214181993
5TXCB006AS3+TSTATS8V2A040M3PDA15.512.07.810,900214181997
5TXCB006AS3+TSTATS8V2A040M3PCA15.512.07.810,900214182003
5TXCB004AS3+TSTAT*UHMB080CCV315.512.07.811,000214181808
5TXCB004AS3+TSTAT*UHMB080ACV315.512.07.811,000214181806
5TXCB004AS3+TSTATS8V2B060M4PCA15.512.07.811,100214181828
5TXCB004AS3+TSTATS8V2B060M4PDA15.512.07.811,100214181833
5TXCB004AS3+TSTATS8V2B080M4PCA15.512.07.811,100214181837
5TXCB004AS3+TSTATS8V2B080M4PCB15.512.07.811,100214181839
5TXCB004AS3+TSTATS8V2B080M4PDA15.512.07.811,100214181841
5TXCB004AS3+TSTATS8V2B080M4PDB15.512.07.811,100214181843
5TXCB004AS3+TSTATS9V2B040U3PSB15.512.07.811,100214181873
5TXCB004AS3+TSTATS9V2B040U3PSC15.512.07.811,100214181875
5TXCB004AS3+TSTATS9V2B040U3VSA15.512.07.811,100214181877
5TXCB004AS3+TSTATS9V2B040U3VSB15.512.07.811,100214181879
5TXCB004AS3+TSTATS9V2B060U3VSA15.512.07.811,100214181881
5TXCB004AS3+TSTATS9V2B060U3VSB15.512.07.811,300214181884
5TXCB004AS3+TSTATS9V2B060U4PSB15.512.07.811,100214181886
5TXCB004AS3+TSTATS9V2B060U4PSC15.512.07.811,100214181888
5TXCB004AS3+TSTAT*UHMB060ACV315.512.07.811,000214181890
5TXCB004AS3+TSTATS9V2B080U4PSB15.512.07.811,100214181892
Yearly running cost in 10 large cities$676-$1,722

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX5024A1?
The Trane 5TWX5024A1 is rated at up to 16.5 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 75 certified matchups SEER2 ranges from 15.2-16.5.
Is the Trane 5TWX5024A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Trane 5TWX5024A1 cost to run per year?
At its rated efficiency it costs about $676-$1,722 a year in electricity in large U.S. cities, depending on climate and local rates - for example $822 in Phoenix and $1,429 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX5024A1?
ENERGY STAR lists 75 certified combinations for this outdoor unit. The highest-rated ones use 5TEMCD06AV41+TDR+TSTAT, 5TEMCD07AV51+TDR+TSTAT, 5TEM6D04AV31+TDR+TSTAT.
What refrigerant does the Trane 5TWX5024A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $809/yrYou save $385/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX5024A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$809
Current system, per year
$1,194
You save per year
$385
Payback
23.4 years
Net after 10 years
-$5,147

Cooling $508Heating $301Electricity used: 5,057 kWhSaved vs. a minimum-efficiency heat pump: $102

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.