9,000 BTU mini-split heat pump · NV-Series
Trane / Mitsubishi Electric NTXSKS09A112
Below average cooling efficiency and very good heating efficiency for a 9,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #337 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $254 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.2 Cooling efficiency over a seasonBelow average · beats 22%
- HSPF2
- 11.9 Heating efficiency over a seasonVery good · beats 88%
- EER2
- 12.6 Cooling efficiency on a 95°F dayAverage · beats 52%
- Heat at 5°F
- 5,900 BTU/h49% of its 47°F outputExcellent · beats 100%
A good fit if…
- It will heat most of the year - its HSPF2 beats 88% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Trane / Mitsubishi Electric |
| Outdoor unit model | NTXSKS09A112 |
| Series | NV-Series |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | December 1, 2022 |
| Last certified | January 8, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.2 (range 19.9-20.2) |
| EER2Efficiency at 95°F outdoors | 12.1-12.6 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 11.1-11.9 |
| Capacity at 47°F | 12,000 BTU/h |
| Capacity at 17°F | 7,600-7,700 BTU/h |
| Capacity at 5°F | 5,200-5,900 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.75-3.12 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NTXUKS09A112 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| NTXUKS09A112 | 20.2 | 12.6 | 11.9 | 5,900 | 207699145 |
| MLZ-KP09NA | 20.2 | 12.6 | 11.9 | 5,900 | 207699139 |
| PEAD-A09AA9 | 19.9 | 12.1 | 11.1 | 5,200 | 213363179 |
Yearly running cost in 10 large cities
- Phoenix, AZ$268/yr
- Miami, FL$210/yr
- Houston, TX$240/yr
- Atlanta, GA$254/yr
- Los Angeles, CA$250/yr
- New York, NY$622/yr
- Chicago, IL$508/yr
- Denver, CO$424/yr
- Seattle, WA$263/yr
- Minneapolis, MN$526/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Trane / Mitsubishi Electric NTXSKS09A112?
- The Trane / Mitsubishi Electric NTXSKS09A112 is rated at up to 20.2 SEER2 and 12.6 EER2 for cooling and up to 11.9 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 19.9-20.2.
- Is the Trane / Mitsubishi Electric NTXSKS09A112 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 9,000 BTU model.
- How much does the Trane / Mitsubishi Electric NTXSKS09A112 cost to run per year?
- At its rated efficiency it costs about $210-$622 a year in electricity in large U.S. cities, depending on climate and local rates - for example $268 in Phoenix and $526 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Trane / Mitsubishi Electric NTXSKS09A112?
- ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use NTXUKS09A112, MLZ-KP09NA, PEAD-A09AA9.
- What refrigerant does the Trane / Mitsubishi Electric NTXSKS09A112 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- KANIONco KD-09IR410AHSODU · cold climate20.2 SEER2 · 12.0 HSPF2
- InfinityLiving EZ-09Z-HP115B20.2 SEER2 · 9.2 HSPF2
- TOSOT TACCI7H4R09 · cold climate20.5 SEER2 · 8.8 HSPF2
- MRCOOL EZPRO-09-HP-C-11516D-O20.2 SEER2 · 9.2 HSPF2
- TOSOT TACCI7H1R09 · cold climate20.5 SEER2 · 8.8 HSPF2
- Hitachi RAC-PH09WHLAE20.0 SEER2 · 11.2 HSPF2
- GREE GWH09ATCXB-D6DNA1C/O · cold climate20.5 SEER2 · 8.8 HSPF2
- Fujitsu AOUH09LPAS120.0 SEER2 · 10.5 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 8, 2026. How we use the data.