HVAC Rated

2-ton central heat pump · 2-STAGE 18 SEER HP

WeatherMaker PH8TAN524**AB

Very good cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #106 of 331 2 ton central heat pumps for cooling efficiency, and costs about $723 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Very good · beats 77%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
11,400 BTU/h45% of its 47°F output
Very good · beats 81%

A good fit if…

  • You want low cooling bills - its SEER2 beats 77% of central heat pumps.
  • You want a choice of indoor units - 187 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandWeatherMaker
Outdoor unit modelPH8TAN524**AB
Series2-STAGE 18 SEER HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 4, 2024
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 15.2-18.5)
EER2Efficiency at 95°F outdoors11.7-14.0
Cooling capacity22,200-25,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F24,000-25,200 BTU/h
Capacity at 17°F14,100-14,900 BTU/h
Capacity at 5°F10,700-11,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.24
ENERGY STAR cold climateNo
Heating output as it gets colder45% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CVAMA3217XMA at the standard test temperatures, in BTU/h:

Certified matchups187 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 187 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CVAMA3217XMAPG80VTLB36070A**18.514.07.810,900218754807
CVAMA3217XMAPG80MSUA36040B**18.514.07.810,800218754804
CAA**3721AMPG97VTAA60080C**18.013.08.511,200218755691
CAA**3721AMPG96VTAB60080C**18.013.08.511,200218755473
CAA**3721AMPG95MSUA60100C**18.013.08.511,200218755469
CAA**3721AMPG80VTLB66110C**18.013.08.511,200218755465
CAA**3721AMPG80MSUA60080C**18.013.58.511,100218755460
CAA**3721AMPG80MSUA48060B**18.013.58.511,200218755459
CAA**3721AMPG80MSUA36040B**18.013.08.511,100218755458
PF5TNXC36L-18.013.08.110,700218755544
CAA**3721AMPG96VTAB60100C**18.013.08.111,100218755474
CAA**3721AMPG96VTAB48060B**18.013.08.111,200218755471
CAA**3721AMPG80VTLB48090B**18.013.08.111,100218755463
CAA**3721AMPG80VTLB48070B**18.013.08.111,100218755462
CAA**2517AMPG80VTLB36070A**18.013.08.111,000218755405
CAA**2517AMPG80MSUA36040B**18.013.08.111,100218755402
CVAVA3817XMAPG80VTLB48090B**18.014.08.011,100218754908
CVAVA3817XMAPG80VTLB48070B**18.013.58.011,100218754907
CVAVA3817XMAPG96VTAB48060B**18.013.57.811,100218754913
CVAVA3721XMAPG96VTAB60080C**18.013.57.810,900218754902
CVAVA3721XMAPG80MSUA60100C**18.013.57.810,900218754890
CVAVA3621XMAPG96VTAB60080C**18.013.57.810,800218754885
CVAVA3621XMAPG80VTLB66110C**18.013.57.810,800218754878
CVAVA3117XMAPG80VTLB36045A**18.013.57.811,000218754851
CVAMA3117XMAPG96VTAB48060B**18.013.57.811,100218754802
QFVA5D3617X-18.014.07.811,300218755720
PF5TNXB24L-17.513.08.111,100218754765
CAA**3721AMPG96VTAB48080B**17.513.08.111,200218755472
CAA**3721AMPG95MSUA60080C**17.513.08.111,100218755468
CAA**3721AMPG95MSUA48060B**17.513.08.111,100218755467
CAA**3721AMPG95MSUA36040B**17.513.08.111,200218755466
CAA**3721AMPG80VTLB60090C**17.513.08.111,100218755464
CAA**3721AMPG80MSUA60100C**17.513.08.111,100218755461
CAA**3717AMPG96VTAB48080B**17.513.08.111,100218755457
CAA**3717AMPG80VTLB48090B**17.513.08.111,000218755450
CAA**3717AMPG80VTLB48070B**17.513.08.111,000218755449
CAA**3717AMPG80VTLB36070A**17.513.08.111,100218755448
CAA**3717AMPG80VTLB36045A**17.513.08.111,100218755447
CAA**3717AMPG80MSUA48060B**17.513.08.111,100218755446
CAA**3717AMPG80MSUA36040B**17.513.08.111,000218755445
CAA**3617AMPG80VTLB36070A**17.512.58.110,900218755435
CAA**3617AMPG80VTLB36045A**17.512.58.110,900218755434
CAA**2517AMPG96VTAB48080B**17.513.08.111,100218755414
CAA**2517AMPG96VTAB48060B**17.513.08.111,200218755413
CAA**2517AMPG95MSUA48060B**17.513.08.111,100218755409
CAA**2517AMPG80VTLB48090B**17.513.08.111,100218755407
CAA**2517AMPG80VTLB48070B**17.513.08.111,100218755406
CAA**2517AMPG80VTLB36045A**17.513.08.111,000218755404
CAA**2517AMPG80MSUA48060B**17.512.58.111,000218755403
CAA**3721AMPG97VTAA60100C**17.513.08.011,100218755692
CAA**3721AMPG97VTAA48080B**17.513.08.011,200218755690
CAA**3721AMPG97VTAA48060B**17.513.08.011,200218755689
CAA**2517AMPG97VTAA48080B**17.513.08.011,100218755682
CAA**2517AMPG97VTAA48060B**17.513.08.011,200218755681
QFVA5D2417X-17.513.57.811,200218755719
CAA**3617AMPG80MSUA48060B**17.513.07.810,900218755433
CAA**3617AMPG80MSUA36040B**17.513.07.810,900218755432
CAA**3017AMPG80MSUA48060B**17.512.07.810,900218755420
CAA**3721AMPG96VTAB36040B**17.012.58.111,400218755470
CAA**3717AMPG96VTAB48060B**17.012.58.111,100218755456
Yearly running cost in 10 large cities$587-$1,777

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the WeatherMaker PH8TAN524**AB?
The WeatherMaker PH8TAN524**AB is rated at up to 18.5 SEER2 and 14.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 187 certified matchups SEER2 ranges from 15.2-18.5.
Is the WeatherMaker PH8TAN524**AB good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the WeatherMaker PH8TAN524**AB cost to run per year?
At its rated efficiency it costs about $587-$1,777 a year in electricity in large U.S. cities, depending on climate and local rates - for example $753 in Phoenix and $1,507 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the WeatherMaker PH8TAN524**AB?
ENERGY STAR lists 187 certified combinations for this outdoor unit. The highest-rated ones use CVAMA3217XMA, CAA**3721AM, PF5TNXC36L.
What refrigerant does the WeatherMaker PH8TAN524**AB use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $762/yrYou save $450/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump WeatherMaker PH8TAN524**AB
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$762
Current system, per year
$1,212
You save per year
$450
Payback
18.9 years
Net after 10 years
-$3,996

Cooling $438Heating $324Electricity used: 4,761 kWhSaved vs. a minimum-efficiency heat pump: $172

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.