HVAC Rated

5-ton central heat pump · SmartSense 20 VS HP

ACIQ B5H0V60*K*AAA

Excellent cooling efficiency and average heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #4 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,714 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 10%
Heat at 5°F
46,000 BTU/h70% of its 47°F output
Average · beats 65%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 950 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandACIQ
Also sold asKenmore, Tempstar, Heil, Arcoaire, Airquest, Keeprite, Day & Night, Comfortmaker
Outdoor unit modelB5H0V60*K*AAA
SeriesSmartSense 20 VS HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 16.5-20.0)
EER2Efficiency at 95°F outdoors8.0-10.0
Cooling capacity54,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.0
Capacity at 47°F57,500-65,000 BTU/h
Capacity at 17°F50,000-57,500 BTU/h
Capacity at 5°F40,500-46,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.86-2.12
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups950 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 950 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218167456
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218167455
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218167454
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218166943
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218166942
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218166941
FCMA5B60L0D*+WALLCON · cold climate-20.010.09.040,500218165628
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.09.09.041,500218355841
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.09.041,500218355839
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.09.041,500218355838
EVM5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.59.044,500218355798
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.59.044,500218355797
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500218355795
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500218355787
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.09.59.044,500218355746
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500218355733
EVM5X61M24A*+WALLCON · cold climate*97CTN1202422A*19.09.59.044,500218169567
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.09.09.041,500218169505
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.09.041,500218169504
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.09.041,500218169503
EVD5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.09.59.044,500218169481
EVD5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500218169480
EVD5X61M21A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500218169475
EVM5X61M24A*+WALLCON · cold climate*96CTN1202422B*19.09.59.044,500218169452
EVM5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.09.59.044,500218169445
EVD5X61M24A*+WALLCON · cold climate*97CTN0802120A*18.59.09.045,000218165797
EVD5X61M24A*+WALLCON · cold climate*96CTN0802120B*18.59.09.045,000218165794
EVD5X61M21A*+WALLCON · cold climate*97CTN1002122A*18.59.09.045,000218165793
EVD5X61M21A*+WALLCON · cold climate*97CTN0802120A*18.59.09.045,000218165792
EVD5X61M21A*+WALLCON · cold climate*96CTN0802120B*18.59.09.045,000218165787
EVD5X60M24A*+WALLCON · cold climate*97CTN1202422A*18.59.09.044,500218165786
EVD5X60M24A*+WALLCON · cold climate*97CTN1002122A*18.59.09.044,500218165785
EVM5X61M24A*+WALLCON · cold climate*97CTN0802120A*18.59.09.045,000218165771
EVM5X61M24A*+WALLCON · cold climate*96CTN0802120B*18.59.09.045,000218165768
EVM5X60M24A*+WALLCON · cold climate*97CTN1202422A*18.59.09.044,500218165767
EVM5X60M24A*+WALLCON · cold climate*97CTN1002122A*18.59.09.044,500218165766
EVM5X60M21A*+WALLCON · cold climate*97CTN1002122A*18.59.09.045,000218165761
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*18.59.09.042,000218165745
EA*5X61M24A*+WALLCON · cold climate*97CTN0802120A*18.59.09.042,000218165744
EA*5X61M24A*+WALLCON · cold climate*96CTN0802120B*18.59.09.042,000218165741
EA*5X60M24A*+WALLCON · cold climate*97CTN1202422A*18.59.09.041,500218165738
EA*5X60M24A*+WALLCON · cold climate*97CTN0802120A*18.58.59.042,000218165736
EA*5X60M24A*+WALLCON · cold climate*96CTN0802120B*18.58.59.042,000218165733
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.59.09.042,000218165718
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.59.09.042,000218165717
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*18.59.09.042,000218165716
EA*5X61M24A*+WALLCON · cold climate*97CMN0802120B*18.59.09.042,000218165715
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.58.59.042,000218165708
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.59.09.041,500218165706
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.59.09.041,500218165698
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.59.09.041,500218165697
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.59.09.041,500218165696
EVD5X61M24A*+WALLCON · cold climate*97CMN0802120B*18.59.09.045,000218165690
EVD5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.59.09.044,500218165679
EVD5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.59.09.044,500218165678
EVD5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.59.09.044,500218165677
EVD5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.59.09.044,500218165676
EVD5X60M21A*+WALLCON · cold climate*80CTL1102120B*18.59.59.044,500218165662
EVD5X60M21A*+WALLCON · cold climate*80CTL0902120B*18.59.59.044,500218165661
EVM5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.59.09.045,000218165650
Yearly running cost in 10 large cities$1,338-$4,254

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ACIQ B5H0V60*K*AAA?
The ACIQ B5H0V60*K*AAA is rated at up to 20.0 SEER2 and 10.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 950 certified matchups SEER2 ranges from 16.5-20.0.
Is the ACIQ B5H0V60*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,000 BTU/h at 5°F with a COP of 2.12, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the ACIQ B5H0V60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,338-$4,254 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,743 in Phoenix and $3,627 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ACIQ B5H0V60*K*AAA?
ENERGY STAR lists 950 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, EA*5X61M24A*+WALLCON, EVM5X61M24A*+WALLCON.
What refrigerant does the ACIQ B5H0V60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,778/yrYou save $1,241/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ACIQ B5H0V60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,778
Current system, per year
$3,020
You save per year
$1,241
Payback
16.9 years
Net after 10 years
-$8,588

Cooling $994Heating $784Electricity used: 11,115 kWhSaved vs. a minimum-efficiency heat pump: $553

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.