HVAC Rated

5-ton central heat pump · QUIETCOMFORT DELUXE 23 VS HP

Heil H5H3V60*K*AAA

Excellent cooling efficiency and below average heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #8 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,743 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
47,500 BTU/h74% of its 47°F output
Average · beats 53%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 47,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 219 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, ACIQ
Outdoor unit modelH5H3V60*K*AAA
SeriesQUIETCOMFORT DELUXE 23 VS HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 17.0-20.0)
EER2Efficiency at 95°F outdoors10.5-12.5
Cooling capacity55,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F60,000-63,500 BTU/h
Capacity at 17°F46,000-49,000 BTU/h
Capacity at 5°F41,000-47,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.95-2.08
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups219 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 219 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500215931488
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500215931489
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500215931490
FCMA5B60L0D*+WALLCON · cold climate-20.012.58.544,500216635230
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500215931516
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500215931517
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500215931518
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000215931667
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000215931666
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000215931668
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500215931676
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500215931677
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500215931678
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500215931696
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500215931697
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500215931698
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500215931707
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500215931706
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500215931708
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000215931716
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000215931718
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000215931717
EA*5X60M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.545,500216635233
EA*5X61M24A*+WALLCON · cold climate*80CSU1002120A*19.011.08.546,500216635249
EA*5X61M24A*+WALLCON · cold climate*80CSU0802120A*19.011.58.546,000216635248
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.78.546,000216635253
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500216635252
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500216635251
EA*5X60M24A*+WALLCON · cold climate*80CSU1002120A*18.511.08.546,000215931526
EA*5X60M24A*+WALLCON · cold climate*80CSU1002120A*18.511.08.546,000215931527
EA*5X60M24A*+WALLCON · cold climate*80CSU1002120A*18.511.08.546,000215931528
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.511.58.545,500215931546
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.511.58.545,500215931547
EA*5X60M24A*+WALLCON · cold climate*80CTL0902120B*18.511.58.545,500215931548
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.511.58.545,500215931557
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.511.58.545,500215931556
EA*5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.511.08.546,000215931616
EA*5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.511.08.546,000215931618
EA*5X60M24A*+WALLCON · cold climate*97CMN1002122B*18.511.08.546,000215931617
EA*5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,000215931627
EA*5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,000215931626
EA*5X60M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,000215931628
EA*5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.511.08.546,000215931636
EA*5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.511.08.546,000215931638
EA*5X60M24A*+WALLCON · cold climate*96CTN1002122B*18.511.08.546,000215931637
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.511.08.546,000215931647
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.511.08.546,000215931646
EA*5X60M24A*+WALLCON · cold climate*96CTN1202422B*18.511.08.546,000215931648
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*18.511.58.545,500215931558
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.511.58.545,500215931567
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.511.58.545,500215931568
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*18.511.58.545,500215931566
EA*5X60M24A*+WALLCON · cold climate*95CSU1002122B*18.511.58.545,500215931586
EA*5X60M24A*+WALLCON · cold climate*95CSU1002122B*18.511.58.545,500215931588
EA*5X60M24A*+WALLCON · cold climate*95CSU1002122B*18.511.58.545,500215931587
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.511.08.547,000215931686
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.511.08.547,000215931687
EA*5X61M24A*+WALLCON · cold climate*80CTL0702120B*18.511.08.547,000215931688
EA*5X61M24A*+WALLCON · cold climate*95CSU0802120B*18.511.08.546,500215931727
EA*5X61M24A*+WALLCON · cold climate*95CSU0802120B*18.511.08.546,500215931726
Yearly running cost in 10 large cities$1,340-$4,344

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil H5H3V60*K*AAA?
The Heil H5H3V60*K*AAA is rated at up to 20.0 SEER2 and 12.5 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 219 certified matchups SEER2 ranges from 17.0-20.0.
Is the Heil H5H3V60*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 47,500 BTU/h at 5°F with a COP of 2.08, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Heil H5H3V60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,340-$4,344 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,757 in Phoenix and $3,711 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil H5H3V60*K*AAA?
ENERGY STAR lists 219 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, EA*5X60M24A*+WALLCON, EA*5X61M24A*+WALLCON.
What refrigerant does the Heil H5H3V60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,798/yrYou save $1,189/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H3V60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,798
Current system, per year
$2,987
You save per year
$1,189
Payback
17.7 years
Net after 10 years
-$9,113

Cooling $994Heating $804Electricity used: 11,239 kWhSaved vs. a minimum-efficiency heat pump: $504

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.