HVAC Rated

2-ton central heat pump · A7HP19V Series

Armstrong Air A7HP19V36P-**A

Excellent cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #32 of 331 2 ton central heat pumps for cooling efficiency, and costs about $703 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
17,700 BTU/h68% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 404 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandArmstrong Air
Also sold asAIREASE
Outdoor unit modelA7HP19V36P-**A
SeriesA7HP19V Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMarch 28, 2025
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 15.2-20.0)
EER2Efficiency at 95°F outdoors11.0-13.2
Cooling capacity21,600-35,600 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F22,800-36,000 BTU/h
Capacity at 17°F13,900-23,000 BTU/h
Capacity at 5°F12,100-17,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.48-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder68% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7E[C,U]24AX-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups404 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 404 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7E[C,U]24AX-**+TDRA80UH2E045A12*20.013.08.516,200217456154
7E[C,U]24BX-**+TDRA80UH2E045A12*20.013.08.516,200217455995
7E[C,U]24AX-**+TDRA80UH2E045A12*20.013.08.516,200217456004
7E[C,U]24BX-**+TDRA80UH2E045A12*20.013.08.516,200217456145
7ED42BX-**+TDREFV12BCA*20.013.08.514,500217547691
7ED42BX-**+TDREFV12BCA*20.013.08.514,500217547724
7E[C,U]30BX-**+TDRA80UH2E045A12*20.013.08.213,700217456030
7E[C,U]30AX-**+TDRA80UH2E045A12*20.013.08.213,700217456050
7AH1AV30PX--20.013.08.215,800217456062
7E[C,U]30BX-**+TDRA80UH2E045A12*20.013.08.213,700217456180
7E[C,U]30AX-**+TDRA80UH2E045A12*20.013.08.213,700217456200
7AH1AV30PX--20.013.08.215,800217456212
7AH2AV30PXC-19.512.88.515,500217202732
7AH1AE24PX--19.513.08.515,600217203023
7AH2AV30PXC-19.512.88.515,500217203032
7AH1AE24PX--19.513.08.515,600217203323
7E[C,U]24AX-**+TDRA80UH1E040A12X*19.513.08.516,500217456152
7E[C,U]24AX-**+TDRA80UH1E060A12X*19.513.08.516,500217456153
7E[C,U]24BX-**+TDRA93UH1E030B12A*19.513.08.516,200217455982
7E[C,U]24BX-**+TDRA80US2V090B12*19.513.08.516,300217455989
7E[C,U]24BX-**+TDRA80US2V090B16*19.513.08.516,300217455990
7E[C,U]24BX-**+TDRA80US2V090B16L*19.513.08.516,300217455991
7E[C,U]24AX-**+TDRA80UH1E040A12X*19.513.08.516,500217456002
7E[C,U]24AX-**+TDRA80UH1E060A12X*19.513.08.516,500217456003
7AH1AE30PX--19.513.08.515,800217456068
7E[C,U]24BX-**+TDRA80US2V090B12*19.513.08.516,300217456139
7E[C,U]24BX-**+TDRA93UH1E030B12A*19.513.08.516,200217456132
7E[C,U]24BX-**+TDRA80US2V090B16*19.513.08.516,300217456140
7E[C,U]24BX-**+TDRA80US2V090B16L*19.513.08.516,300217456141
7AH1AE30PX--19.513.08.515,800217456218
7E[C,U]24BX-**+TDRA97UH2E030B08S*19.513.08.516,300217547710
7E[C,U]24BX-**+TDRA97UH2E030B08S*19.513.08.516,300217547677
7E[C,U]24BX-**+TDREFV12BCA*19.513.28.516,400217547679
7E[C,U]24BX-**+TDREFV12BCA*19.513.28.516,400217547712
7E[C,U]30BX-**+TDRA80US2V090B12*19.513.08.213,800217456023
7E[C,U]30BX-**+TDRA98USMV070B12S*19.513.08.213,800217456028
7E[C,U]30BX-**+TDRA80US2V090B12*19.513.08.213,800217456173
7E[C,U]30BX-**+TDRA98USMV070B12S*19.513.08.213,800217456178
7E[C,U]30BX-**+TDRA93UH1E030B12A*19.513.08.113,700217456014
7E[C,U]30BX-**+TDRA97US2V040B12X*19.512.88.113,900217456026
7E[C,U]30BX-**+TDRA97US2V070B12S*19.513.08.113,800217456040
7E[C,U]30AX-**+TDRA80US2V060A12X*19.513.08.113,800217456059
7E[C,U]30BX-**+TDRA93UH1E030B12A*19.513.08.113,700217456164
7E[C,U]30BX-**+TDRA97US2V040B12X*19.512.88.113,900217456176
7E[C,U]30BX-**+TDRA97US2V070B12S*19.513.08.113,800217456190
7E[C,U]30AX-**+TDRA80US2V060A12X*19.513.08.113,800217456209
7E[C,U]30BX-**+TDRA97UH2E030B08S*19.512.88.113,800217547682
7E[C,U]30BX-**+TDREFV12BCA*19.513.08.113,900217547684
7E[C,U]30BX-**+TDRA97UH2E030B08S*19.512.88.113,800217547715
7E[C,U]30BX-**+TDREFV12BCA*19.513.08.113,900217547717
7E[C,U]24BX-**+TDRA80UH2E070A12*19.013.08.516,600217456146
7E[C,U]24BX-**+TDRA97US2V045B12S*19.013.08.516,400217456149
7E[C,U]24BX-**+TDRA97US2V070B12S*19.013.08.516,300217456150
7E[C,U]24AX-**+TDRA80UH2E070A12*19.013.08.516,600217456155
7E[C,U]24AX-**+TDRA80UH1E045A12*19.013.08.516,200217456156
7E[C,U]24AX-**+TDRA80US2V060A12X*19.013.08.516,400217456158
7E[C,U]24BX-**+TDRA80UH2E090B12*19.013.08.516,600217455980
7E[C,U]24BX-**+TDRA93UH1E045B12A*19.013.08.516,600217455983
7E[C,U]24BX-**+TDRA93UH1E070B12A*19.013.08.516,500217455984
7E[C,U]24BX-**+TDRA96UH1E030B12S*19.013.08.516,200217455985
Yearly running cost in 10 large cities$567-$1,731

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Armstrong Air A7HP19V36P-**A?
The Armstrong Air A7HP19V36P-**A is rated at up to 20.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 404 certified matchups SEER2 ranges from 15.2-20.0.
Is the Armstrong Air A7HP19V36P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Armstrong Air A7HP19V36P-**A cost to run per year?
At its rated efficiency it costs about $567-$1,731 a year in electricity in large U.S. cities, depending on climate and local rates - for example $729 in Phoenix and $1,469 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Armstrong Air A7HP19V36P-**A?
ENERGY STAR lists 404 certified combinations for this outdoor unit. The highest-rated ones use 7E[C,U]24AX-**+TDR, 7E[C,U]24BX-**+TDR, 7ED42BX-**+TDR.
What refrigerant does the Armstrong Air A7HP19V36P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $739/yrYou save $499/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Armstrong Air A7HP19V36P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$739
Current system, per year
$1,238
You save per year
$499
Payback
18.0 years
Net after 10 years
-$4,011

Cooling $422Heating $316Electricity used: 4,616 kWhSaved vs. a minimum-efficiency heat pump: $211

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.