2-ton central heat pump · NS19H Series
GE NS19H36MA5-**A
Excellent cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #35 of 331 2 ton central heat pumps for cooling efficiency, and costs about $703 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonExcellent · beats 94%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 17,700 BTU/h68% of its 47°F outputVery good · beats 76%
A good fit if…
- You want low cooling bills - its SEER2 beats 94% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 152 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS19H36MA5-**A |
| Series | NS19H Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | September 4, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 15.2-20.0) |
| EER2Efficiency at 95°F outdoors | 11.0-13.2 |
| Cooling capacity | 21,600-35,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.5 |
| Capacity at 47°F | 22,800-35,400 BTU/h |
| Capacity at 17°F | 14,200-21,600 BTU/h |
| Capacity at 5°F | 13,700-17,700 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.48-2.20 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NCU[C,U]24AT5*-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 152 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NCU[C,U]24AT5*-**+TDR | NF80U045T3A* | 20.0 | 13.0 | 8.5 | 16,200 | 217733167 |
| NCU[C,U]24BT5*-**+TDR | NF97U070V3B* | 20.0 | 13.2 | 8.5 | 16,400 | 217733284 |
| NCDC42BT5*-**+TDR | NF97D070V4B* | 20.0 | 12.6 | 8.5 | 14,700 | 217733301 |
| NCU[C,U]24BT5*-**+TDR | NF80U045T3A* | 20.0 | 13.0 | 8.5 | 16,200 | 217733162 |
| NCU[C,U]30BT5*-**+TDR | NF80U045T3A* | 20.0 | 13.0 | 8.2 | 13,700 | 217733190 |
| NCU[C,U]30AT5*-**+TDR | NF80U045T3A* | 20.0 | 13.0 | 8.2 | 13,700 | 217733202 |
| NAM30V1TA5*- | - | 20.0 | 13.0 | 8.2 | 15,800 | 217733209 |
| NCU[C,U]30BT5*-**+TDR | NF97U070V3B* | 20.0 | 13.0 | 8.1 | 13,800 | 217733290 |
| NCU[C,U]24AT5*-**+TDR | NF80X040S3A* | 19.5 | 13.0 | 8.5 | 16,500 | 217733165 |
| NCU[C,U]24AT5*-**+TDR | NF80X060S3A* | 19.5 | 13.0 | 8.5 | 16,500 | 217733166 |
| NAM30V2TA5*- | - | 19.5 | 12.8 | 8.5 | 15,500 | 217732942 |
| NAM30E1TA5*- | - | 19.5 | 13.0 | 8.5 | 15,800 | 217733216 |
| NAM24E1TA5*- | - | 19.5 | 13.0 | 8.5 | 15,600 | 217733117 |
| NCU[C,U]24BT5*-**+TDR | NF80U090V4B* | 19.5 | 13.0 | 8.5 | 16,500 | 217733283 |
| NCU[C,U]36BT5*-**+TDR | NF97U070V3B* | 19.5 | 13.2 | 8.5 | 15,100 | 217733293 |
| NCU[C,U]30BT5*-**+TDR | NF98U070M3B* | 19.5 | 13.0 | 8.2 | 13,800 | 217733189 |
| NCU[C,U]30BT5*-**+TDR | NF97X040V3B* | 19.5 | 12.8 | 8.1 | 13,900 | 217733187 |
| NCU[C,U]30AT5*-**+TDR | NF80X060V3A* | 19.5 | 13.0 | 8.1 | 13,800 | 217733208 |
| NCU[C,U]30BT5*-**+TDR | NF80U090V4B* | 19.5 | 12.8 | 8.1 | 13,900 | 217733289 |
| NCU[C,U]24BT5*-**+TDR | NF97X040V3B* | 19.0 | 13.0 | 8.5 | 16,400 | 217733159 |
| NCU[C,U]24BT5*-**+TDR | NF97X060V3B* | 19.0 | 13.0 | 8.5 | 16,400 | 217733160 |
| NCU[C,U]24BT5*-**+TDR | NF98U070M3B* | 19.0 | 13.0 | 8.5 | 16,300 | 217733161 |
| NCU[C,U]24BT5*-**+TDR | NF80U070T3A* | 19.0 | 13.0 | 8.5 | 16,600 | 217733163 |
| NCU[C,U]24AT5*-**+TDR | NF80U070T3A* | 19.0 | 13.0 | 8.5 | 16,600 | 217733168 |
| NCU[C,U]24AT5*-**+TDR | NF80U045S3A* | 19.0 | 13.0 | 8.5 | 16,200 | 217733169 |
| NCU[C,U]24AT5*-**+TDR | NF80L045S3A* | 19.0 | 13.0 | 8.5 | 16,200 | 217733170 |
| NCU[C,U]24AT5*-**+TDR | NF80X060V3A* | 19.0 | 13.0 | 8.5 | 16,400 | 217733173 |
| NCU[C,U]36BT5*-**+TDR | NF97X040V3B* | 19.0 | 13.0 | 8.5 | 15,200 | 217732945 |
| NCU[C,U]36BT5*-**+TDR | NF97X060V3B* | 19.0 | 13.0 | 8.5 | 15,200 | 217732946 |
| NCU[C,U]36BT5*-**+TDR | NF98U070M3B* | 19.0 | 13.0 | 8.5 | 15,100 | 217732947 |
| NCU[C,U]36AT5*-**+TDR | NF80X060V3A* | 19.0 | 13.0 | 8.5 | 15,100 | 217732949 |
| NCU[C,U]24AT5*-**+TDR | NF80U070V3A* | 19.0 | 13.2 | 8.5 | 16,400 | 217733282 |
| NCU[C,U]36AT5*-**+TDR | NF80U070V3A* | 19.0 | 13.0 | 8.5 | 15,200 | 217733291 |
| NCU[C,U]24BT5*-**+TDR | NF97U045V3B* | 19.0 | 13.0 | 8.5 | 16,400 | 217733157 |
| NAM24V1TA5*- | - | 19.0 | 12.8 | 8.2 | 15,600 | 217732950 |
| NCU[C,U]36AT5*-**+TDR | NF80U045T3A* | 19.0 | 11.0 | 8.2 | 15,100 | 217732965 |
| NCU[C,U]30BT5*-**+TDR | NF80U070T3A* | 19.0 | 12.6 | 8.2 | 14,100 | 217733191 |
| NCU[C,U]30AT5*-**+TDR | NF80X040S3A* | 19.0 | 12.8 | 8.2 | 14,000 | 217733200 |
| NCU[C,U]30AT5*-**+TDR | NF80X060S3A* | 19.0 | 12.8 | 8.2 | 14,000 | 217733201 |
| NCU[C,U]30AT5*-**+TDR | NF80U070T3A* | 19.0 | 12.6 | 8.2 | 14,100 | 217733203 |
| NCU[C,U]30AT5*-**+TDR | NF80U045S3A* | 19.0 | 13.0 | 8.2 | 13,700 | 217733204 |
| NCU[C,U]30AT5*-**+TDR | NF80L045S3A* | 19.0 | 13.0 | 8.2 | 13,700 | 217733205 |
| NCU[C,U]30AT5*-**+TDR | NF80U070V3A* | 19.0 | 13.0 | 8.2 | 13,900 | 217733288 |
| NCU[C,U]30BT5*-**+TDR | NF97U045V3B* | 19.0 | 13.0 | 8.1 | 13,800 | 217733183 |
| NCU[C,U]30BT5*-**+TDR | NF80X080V4B* | 19.0 | 12.8 | 8.1 | 13,900 | 217733185 |
| NCU[C,U]30BT5*-**+TDR | NF97X060V3B* | 19.0 | 12.8 | 8.1 | 13,900 | 217733188 |
| NCU[C,U]24BT5*-**+TDR | NF80U070S3B* | 18.5 | 13.0 | 8.5 | 16,300 | 217733153 |
| NCU[C,U]24BT5*-**+TDR | NF80L070S3B* | 18.5 | 13.0 | 8.5 | 16,300 | 217733154 |
| NCU[C,U]24BT5*-**+TDR | NF96U070S3B* | 18.5 | 13.0 | 8.5 | 16,500 | 217733156 |
| NCU[C,U]24BT5*-**+TDR | NF80X080V4B* | 18.5 | 13.0 | 8.5 | 16,500 | 217733158 |
| NCU[C,U]36BT5*-**+TDR | NF80X080V4B* | 18.5 | 12.8 | 8.5 | 15,200 | 217732944 |
| NCU[C,U]24BT5*-**+TDR | NF97U070T3B* | 18.5 | 12.8 | 8.5 | 16,700 | 218159795 |
| NCU[C,U]30BT5*-**+TDR | NF80U070S3B* | 18.5 | 13.0 | 8.2 | 13,800 | 217733177 |
| NCU[C,U]30BT5*-**+TDR | NF80L070S3B* | 18.5 | 13.0 | 8.2 | 13,800 | 217733178 |
| NCU[C,U]36AT5*-**+TDR | NF80X040S3A* | 18.5 | 11.0 | 8.2 | 14,900 | 217732963 |
| NCU[C,U]36AT5*-**+TDR | NF80U070T3A* | 18.5 | 11.0 | 8.2 | 14,800 | 217732966 |
| NCU[C,U]36AT5*-**+TDR | NF80U045S3A* | 18.5 | 11.0 | 8.2 | 14,900 | 217732967 |
| NCU[C,U]36AT5*-**+TDR | NF80L045S3A* | 18.5 | 11.0 | 8.2 | 14,900 | 217732968 |
| NCU[C,U]30AT5*-**+TDR | NF80L070S3A* | 18.5 | 13.0 | 8.2 | 13,800 | 217733207 |
| NCHC30BT5*-**+TDR | NF97U070V3B* | 18.5 | 12.4 | 8.2 | 15,100 | 217733307 |
Yearly running cost in 10 large cities
- Phoenix, AZ$729/yr
- Miami, FL$567/yr
- Houston, TX$654/yr
- Atlanta, GA$703/yr
- Los Angeles, CA$693/yr
- New York, NY$1,731/yr
- Chicago, IL$1,415/yr
- Denver, CO$1,184/yr
- Seattle, WA$734/yr
- Minneapolis, MN$1,469/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS19H36MA5-**A?
- The GE NS19H36MA5-**A is rated at up to 20.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 152 certified matchups SEER2 ranges from 15.2-20.0.
- Is the GE NS19H36MA5-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the GE NS19H36MA5-**A cost to run per year?
- At its rated efficiency it costs about $567-$1,731 a year in electricity in large U.S. cities, depending on climate and local rates - for example $729 in Phoenix and $1,469 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS19H36MA5-**A?
- ENERGY STAR lists 152 certified combinations for this outdoor unit. The highest-rated ones use NCU[C,U]24AT5*-**+TDR, NCU[C,U]24BT5*-**+TDR, NCDC42BT5*-**+TDR.
- What refrigerant does the GE NS19H36MA5-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Friedrich FRP18AZ24AJVC · cold climate20.0 SEER2 · 8.5 HSPF2
- Rheem RP18AZ24AJVC · cold climate20.0 SEER2 · 8.5 HSPF2
- Century HSA1936V1-**A20.0 SEER2 · 8.5 HSPF2
- Sure SP18AZ24AJVC · cold climate20.0 SEER2 · 8.5 HSPF2
- Armstrong Air A7HP19V36P-**A20.0 SEER2 · 8.5 HSPF2
- Trane/American Standard 5HCL9024A1000A · cold climate19.7 SEER2 · 8.8 HSPF2
- ALLIED 7HP19V36P-**A20.0 SEER2 · 8.5 HSPF2
- Arcoaire Q5H9V24*K*AAA · cold climate19.5 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.