HVAC Rated

2.5-ton central heat pump · EVOLUTION Extreme 24 HP

Bryant 284ANV036*0**B

Very good cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #17 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $958 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
26,800 BTU/h74% of its 47°F output
Below average · beats 15%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 26,800 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandBryant
Outdoor unit model284ANV036*0**B
SeriesEVOLUTION Extreme 24 HP
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 15, 2021
Last certifiedFebruary 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 18.0-19.0)
EER2Efficiency at 95°F outdoors10.5-11.5
Cooling capacity32,000-34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0-9.5
Capacity at 47°F34,800-35,800 BTU/h
Capacity at 17°F30,200-32,800 BTU/h
Capacity at 5°F25,000-26,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.88
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAP**4821AL*+UI at the standard test temperatures, in BTU/h:

Certified matchups8 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAP**4821AL*+UI · cold climate987TA48080C17***19.011.09.025,800217106207
CAP**6121AL*+UI · cold climate987TA48060C17***19.011.09.025,200217106208
CAP**6121AL*+UI · cold climate987TA48080C17***19.011.59.025,000217106209
CAP**4221AL*+UI · cold climate987TA48080C17***18.511.09.526,400217106205
CAP**4821AL*+UI · cold climate987TA48060C17***18.511.09.025,800217106206
CAP**3617AL*+UI · cold climate987TA48060C17***18.010.59.026,800217106202
CAP**3617AL*+UI · cold climate987TA48080C17***18.010.59.026,800217106203
CAP**4221AL*+UI · cold climate987TA48060C17***18.010.59.026,400217106204
Yearly running cost in 10 large cities$818-$2,321

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant 284ANV036*0**B?
The Bryant 284ANV036*0**B is rated at up to 19.0 SEER2 and 11.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 8 certified matchups SEER2 ranges from 18.0-19.0.
Is the Bryant 284ANV036*0**B good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 26,800 BTU/h at 5°F with a COP of 1.88, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Bryant 284ANV036*0**B cost to run per year?
At its rated efficiency it costs about $818-$2,321 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,027 in Phoenix and $1,953 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant 284ANV036*0**B?
ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use CAP**4821AL*+UI, CAP**6121AL*+UI, CAP**4221AL*+UI.
What refrigerant does the Bryant 284ANV036*0**B use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,029/yrYou save $712/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 284ANV036*0**B
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,029
Current system, per year
$1,741
You save per year
$712
Payback
17.6 years
Net after 10 years
-$5,379

Cooling $611Heating $417Electricity used: 6,429 kWhSaved vs. a minimum-efficiency heat pump: $312

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 27, 2026. How we use the data.