HVAC Rated

9,000 BTU mini-split heat pump · D5M Series

Carrier 37MVRAQ09AA3

Below average cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #375 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $264 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Below average · beats 9%
HSPF2
9.7 Heating efficiency over a season
Below average · beats 31%
EER2
10.9 Cooling efficiency on a 95°F day
Below average · beats 7%
Heat at 5°F
7,000 BTU/h70% of its 47°F output
Very good · beats 73%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 7,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 10 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications9,000 BTU, R-454B
General
BrandCarrier
Also sold asBryant, Payne, Midea, WeatherMaker
Outdoor unit model37MVRAQ09AA3
SeriesD5M Series
TypeMini-split heat pump
Nominal size9,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 15, 2018
Last certifiedMarch 4, 2025
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 19.0)
EER2Efficiency at 95°F outdoors10.9
Cooling capacity9,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.7
Capacity at 47°F10,000 BTU/h
Capacity at 17°F8,000 BTU/h
Capacity at 5°F7,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.15
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with D5MVHAQ09XA3 at the standard test temperatures, in BTU/h:

Certified matchups10 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
D5MVHAQ09XA3 CARRIER · cold climate19.010.99.77,000215323838
D5MVHAQ09XA3 BRYANT · cold climate19.010.99.77,000215323899
D5MVHAQ09XA3 PAYNE · cold climate19.010.99.77,000215323960
D5MVHAQ09XA3 MIDEA · cold climate19.010.99.77,000215324082
D5MVHAQ09XA3 Weathermaker · cold climate19.010.99.77,000215324021
D5MVHAQ09XC3 CARRIER · cold climate19.010.99.77,000215333739
D5MVHAQ09XC3 BRYANT · cold climate19.010.99.77,000215333745
D5MVHAQ09XC3 PAYNE · cold climate19.010.99.77,000215333751
D5MVHAQ09XC3 Weathermaker · cold climate19.010.99.77,000215333757
D5MVHAQ09XC3 MIDEA · cold climate19.010.99.77,000215333763
Yearly running cost in 10 large cities$223-$640

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Carrier 37MVRAQ09AA3?
The Carrier 37MVRAQ09AA3 is rated at up to 19.0 SEER2 and 10.9 EER2 for cooling and up to 9.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Carrier 37MVRAQ09AA3 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 7,000 BTU/h at 5°F with a COP of 2.15, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Carrier 37MVRAQ09AA3 cost to run per year?
At its rated efficiency it costs about $223-$640 a year in electricity in large U.S. cities, depending on climate and local rates - for example $281 in Phoenix and $540 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Carrier 37MVRAQ09AA3?
ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use CARRIER D5MVHAQ09XA3, BRYANT D5MVHAQ09XA3, PAYNE D5MVHAQ09XA3.
What refrigerant does the Carrier 37MVRAQ09AA3 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $282/yrYou save $198/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 37MVRAQ09AA3
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$282
Current system, per year
$480
You save per year
$198
Payback
17.7 years
Net after 10 years
-$1,518

Cooling $167Heating $115Electricity used: 1,764 kWhSaved vs. a minimum-efficiency heat pump: $89

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 9,000 BTU models

See all 395 9,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 4, 2025. How we use the data.