HVAC Rated

2-ton central heat pump · LX SERIES

Coleman THF2B24T21

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #286 of 331 2 ton central heat pumps for cooling efficiency, and costs about $746 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
12,000 BTU/h52% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 837 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandColeman
Also sold asLuxaire, CHAMPION HEATING AND COOLING, Johnson Controls, Fraser-Johnston
Outdoor unit modelTHF2B24T21
SeriesLX SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 18, 2023
Last certifiedJuly 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity22,800-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F20,600-22,800 BTU/h
Capacity at 17°F13,100-14,500 BTU/h
Capacity at 5°F9,600-12,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder52% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAFB30CBAN1 at the standard test temperatures, in BTU/h:

Certified matchups837 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 837 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAFB30CBAN1Z8ES080B12SMPS116.011.78.111,600212479103
XAHB36DBAN1Z8ES040A12LMPS116.011.78.111,500212480569
XAFB30CBAN1Z8ES040A12SMPS116.011.78.111,700212486655
XAFB30CBAN1Z8ES040A12SMPS116.011.78.111,700212486654
XAHB30CBAN1Z8ES080B12LMPS116.011.78.111,600212486641
XAFB30CBAN1Z8ES040A12LMPS116.011.78.111,700212486666
XAFB30CBAN1Z8ES040A12LMPS116.011.78.111,700212486664
XAFB36DBAN1Z8ES040A12LMPS116.011.78.111,400212486724
XAFB30CBAN1Z8ES040A12LMPS116.011.78.111,700212486667
XAFB36DXXN1+TXVZ8ES040A12SMPS116.011.78.111,400212486705
XAFB36DBAN1Z8ES040A12SMPS116.011.78.111,400212486716
XAFB36DXXN1+TXVZ8ES040A12LMPS116.011.78.111,400212486707
XAFB36DXXN1+TXVZ8ES040A12SMPS116.011.78.111,400212486703
XAHB30CBAN1Z8ES080B12SMPS116.011.78.111,600212486633
XAHC36DBAN1Z8ES100B12LMPS116.012.08.111,500212488849
XAHB30CBAN1Z8ES080B12SMPS116.011.78.111,600212486630
XAFB36DBAN1Z8ES040A12SMPS116.011.78.111,400212486717
XAFC30CBAN1Z8ES080B12SMPS116.011.78.111,600212488817
XAHC36DBAN1Z8ES100B12SMPS116.012.08.111,500212488841
XAHB30CBAN1Z8ES080B12SMPS116.011.78.111,600212486634
XAHC36DBAN1Z8ES100B12LMPS116.012.08.111,500212488844
XAHC30CBAN1Z8ES080B12SMPS116.011.78.111,600212480495
XAFB36DXXN1+TXVZ8ES040A12LMPS116.011.78.111,400212486713
XAFB36DBAN1Z8ES100B12LMPS116.011.78.111,400212481525
XAFB36DBAN1Z8ES100B12LMPS116.011.78.111,400212481527
XAFB36DXXN1+TXVZ8ES100B12LMPS116.011.78.111,400212481510
XAHB36DBAN1Z8ES040A12SMPS116.011.78.111,500212480564
XAHB30CBAN1Z8ES080B12LMPS116.011.78.111,600212486635
XAHB30CBAN1Z8ES080B12SMPS116.011.78.111,600212486631
XAHB36DBAN1Z8ES080B12SMPS116.011.78.111,400212480541
XAFB36DBAN1Z8ES100B12SMPS116.011.78.111,400212481515
XAHB30CBAN1Z8ES040A12SMPS116.011.78.111,700212480520
XAHB30CBAN1Z8ES040A12LMPS116.011.78.111,700212480522
XAFC30CBAN1Z8ES080B12LMPS116.011.78.111,600212488822
XAFB36DXXN1+TXVZ8ES040A12SMPS116.011.78.111,400212486704
XAHC36DBAN1Z8ES100B12SMPS116.012.08.111,500212488839
XAFB36DBAN1Z8ES040A12LMPS116.011.78.111,400212486727
XAFB36DXXN1+TXVZ8ES040A12SMPS116.011.78.111,400212486706
XAHB36DBAN1Z8ES080B12LMPS116.011.78.111,400212480545
XAHB30CBAN1Z8ES040A12LMPS116.011.78.111,700212480524
XAHC36DBAN1Z8ES100B12SMPS116.012.08.111,500212488842
XAHC36DBAN1Z8ES100B12LMPS116.012.08.111,500212488843
XAHC36DBAN1Z8ES100B12SMPS116.012.08.111,500212488838
XAFB36DBAN1Z8ES040A12SMPS116.011.78.111,400212486718
XAFB36DXXN1+TXVZ8ES040A12LMPS116.011.78.111,400212486710
XAFB36DXXN1+TXVZ8ES040A12SMPS116.011.78.111,400212486702
XAFC30CBAN1Z8ES080B12LMPS116.011.78.111,600212488825
XAHC36DBAN1Z8ES100B12SMPS116.012.08.111,500212488840
XAFC30CBAN1Z8ES080B12SMPS116.011.78.111,600212488814
XAFC30CBAN1Z8ES080B12SMPS116.011.78.111,600212488818
XAFC30CBAN1Z8ES080B12SMPS116.011.78.111,600212488815
XAFB36DBAN1Z8ES040A12LMPS116.011.78.111,400212486725
XAFB36DXXN1+TXVZ8ES040A12LMPS116.011.78.111,400212486709
XAFB36DXXN1+TXVZ8ES040A12LMPS116.011.78.111,400212486708
XAFC30CBAN1Z8ES080B12SMPS116.011.78.111,600212488816
XAFC30CBAN1Z8ES080B12LMPS116.011.78.111,600212488819
XAFB36DBAN1Z8ES040A12SMPS116.011.78.111,400212486715
XAHC36DBAN1Z8ES100B12LMPS116.012.08.111,500212488845
XAHB30CBAN1Z8ES040A12LMPS116.011.78.111,700212480523
XAHB30CBAN1Z8ES040A12SMPS116.011.78.111,700212480519
Yearly running cost in 10 large cities$697-$1,758

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Coleman THF2B24T21?
The Coleman THF2B24T21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 837 certified matchups SEER2 ranges from 15.2-16.0.
Is the Coleman THF2B24T21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Coleman THF2B24T21 cost to run per year?
At its rated efficiency it costs about $697-$1,758 a year in electricity in large U.S. cities, depending on climate and local rates - for example $845 in Phoenix and $1,457 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Coleman THF2B24T21?
ENERGY STAR lists 837 certified combinations for this outdoor unit. The highest-rated ones use XAFB30CBAN1, XAHB36DBAN1, XAHB30CBAN1.
What refrigerant does the Coleman THF2B24T21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $831/yrYou save $370/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Coleman THF2B24T21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$831
Current system, per year
$1,201
You save per year
$370
Payback
24.3 years
Net after 10 years
-$5,296

Cooling $524Heating $307Electricity used: 5,191 kWhSaved vs. a minimum-efficiency heat pump: $87

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 7, 2026. How we use the data.