HVAC Rated

2-ton central heat pump · ELITE EL16KP1 Series

Lennox EL16KP1-024-230A

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #284 of 331 2 ton central heat pumps for cooling efficiency, and costs about $736 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
13.8 Cooling efficiency on a 95°F day
Excellent · beats 97%
Heat at 5°F
11,600 BTU/h51% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 179 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandLennox
Outdoor unit modelEL16KP1-024-230A
SeriesELITE EL16KP1 Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 1, 2024
Last certifiedAugust 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.0-13.8
Cooling capacity22,800-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F20,400-23,000 BTU/h
Capacity at 17°F12,900-14,700 BTU/h
Capacity at 5°F10,500-11,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CBK45UHET-030-230- at the standard test temperatures, in BTU/h:

Certified matchups179 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 179 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CBK45UHET-030-230--16.013.88.111,300215710360
CK40HT-30B-**+TDRML180UH070V36B*16.013.48.010,900215710547
CBK47UHET-030-230--15.513.28.211,400215710365
CBK48MVT-030-230--15.513.08.211,400215710367
CK40[C,U]T-30B-**+TDREL280UH090E48B*15.513.28.111,400215710440
CK40[C,U]T-30B-**+TDREL280UH090XE48B*15.513.28.111,400215710441
CK40[C,U]T-30B-**+TDRML180UH070V48B*15.513.28.111,400215710448
CK40[C,U]T-30B-**+TDRML180UH090E48B*15.513.28.111,400215710450
CK40[C,U]T-30B-**+TDRML180UH090XE48B*15.513.28.111,400215710452
CK40HT-24B-**+TDREL280UH090E48B*15.513.28.110,800215710490
CK40HT-24B-**+TDREL280UH090XE48B*15.513.28.110,700215710491
CK40HT-24B-**+TDREL297UH070XV36B*15.513.28.110,600215710495
CK40HT-24B-**+TDRML180UH070E36B*15.513.28.110,600215710496
CK40HT-24B-**+TDRML180UH070V36B*15.513.28.110,600215710497
CK40HT-24B-**+TDRML180UH070XE36B*15.513.28.110,600215710499
CK40HT-24B-**+TDRML180UH070V48B*15.513.28.110,700215710498
CK40HT-24B-**+TDRML180UH090E48B*15.513.48.110,700215710500
CK40HT-24B-**+TDRML180UH090XE48B*15.513.48.110,700215710502
CK40HT-30B-**+TDRML180UH090E48B*15.513.48.111,000215710550
CK40HT-30B-**+TDRML180UH090XE48B*15.513.48.111,000215710552
CBK45UHVT-030-230--15.513.68.111,600215710363
CK40[C,U]T-24B-**+TDREL280UH090XE48B*15.513.28.010,900215710391
CK40[C,U]T-24B-**+TDRML180UH090E48B*15.513.28.010,800215710400
CK40[C,U]T-24B-**+TDRML180UH090XE48B*15.513.28.010,800215710402
CK40[C,U]T-30A-**+TDREL280UH045E36A*15.513.28.011,200215710420
CK40[C,U]T-30A-**+TDRML180UH030V36A*15.513.28.011,300215710423
CK40[C,U]T-30A-**+TDRML180UH045V36A*15.513.28.011,200215710425
CK40[C,U]T-30A-**+TDRML180UH070E36A*15.513.28.011,300215710427
CK40[C,U]T-30A-**+TDRML180UH070V36A*15.513.28.011,300215710428
CK40[C,U]T-30A-**+TDRML180UH070XE36A*15.513.28.011,300215710429
CK40[C,U]T-30A-**+TDRSL280UH060NV36A*15.513.28.011,300215710430
CK40[C,U]T-30A-**+TDRSL280UH070V36A*15.513.08.011,400215710431
CK40[C,U]T-30B-**+TDREL297UH070XV36B*15.513.28.011,300215710445
CK40[C,U]T-30B-**+TDRML180UH070E36B*15.513.28.011,300215710446
CK40[C,U]T-30B-**+TDRML180UH070V36B*15.513.28.011,300215710447
CK40[C,U]T-30B-**+TDRML180UH070XE36B*15.513.28.011,300215710449
CK40[C,U]T-30B-**+TDRML296UH045XV36B*15.513.08.011,300215710460
CK40[C,U]T-30B-**+TDRML296UH070XV36B*15.513.08.011,400215710461
CK40[C,U]T-30B-**+TDRSL280UH090V36B*15.513.28.011,400215710463
CK40[C,U]T-30B-**+TDRSL280UH090V48B*15.513.28.011,300215710464
CK40[C,U]T-30B-**+TDRSLP99UH070XV36B*15.513.08.011,300215710467
CK40HT-30A-**+TDRML180UH070V36A*15.513.28.011,000215710528
CK40HT-30B-**+TDREL280UH090E48B*15.513.48.011,000215710540
CK40HT-30B-**+TDREL280UH090XE48B*15.513.48.011,000215710541
CK40HT-30B-**+TDRML180UH070E36B*15.513.48.010,900215710546
CK40HT-30B-**+TDREL297UH070XV36B*15.513.28.011,000215710545
CK40HT-30B-**+TDRML180UH070XE36B*15.513.48.010,900215710549
CK40HT-30B-**+TDRML180UH070V48B*15.513.48.010,900215710548
CK40HT-30B-**+TDRML193UH070XE36B*15.513.28.011,100215710555
CK40HT-30B-**+TDRML196UH070XE36B*15.513.28.011,100215710558
CK40HT-30B-**+TDRML296UH070XV36B*15.513.28.010,900215710561
CK40HT-30B-**+TDRSL280UH090V36B*15.513.28.011,000215710563
CK40HT-30B-**+TDRSL280UH090V48B*15.513.28.010,900215710564
CK40[C,U]T-24B-**+TDREL280UH090E48B*15.513.28.010,900215710390
CK40HT-30B-**+TDRML297UH070XV36B*15.513.28.011,000218691023
CK40[C,U]T-30B-**+TDRML297UH070XV36B*15.513.08.011,500218691019
CK40[C,U]T-30B-**+TDRML297UH045XV36B*15.513.08.011,300218691012
CK40[C,U]T-24B-**+TDREL297UH070XV36B*15.513.27.810,800215710395
CK40[C,U]T-24B-**+TDRML180UH070E36B*15.513.27.810,800215710396
CK40[C,U]T-24B-**+TDRML180UH070V36B*15.513.27.810,800215710397
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Lennox EL16KP1-024-230A: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$697-$1,728

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Lennox EL16KP1-024-230A?
The Lennox EL16KP1-024-230A is rated at up to 16.0 SEER2 and 13.8 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 179 certified matchups SEER2 ranges from 15.2-16.0.
Is the Lennox EL16KP1-024-230A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Lennox EL16KP1-024-230A cost to run per year?
At its rated efficiency it costs about $697-$1,728 a year in electricity in large U.S. cities, depending on climate and local rates - for example $840 in Phoenix and $1,429 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Lennox EL16KP1-024-230A the same as the Lennox ML14KP1-024-230A?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Lennox EL16KP1-024-230A?
ENERGY STAR lists 179 certified combinations for this outdoor unit. The highest-rated ones use CBK45UHET-030-230-, CK40HT-30B-**+TDR, CBK47UHET-030-230-.
What refrigerant does the Lennox EL16KP1-024-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $824/yrYou save $374/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL16KP1-024-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$824
Current system, per year
$1,198
You save per year
$374
Payback
24.1 years
Net after 10 years
-$5,264

Cooling $524Heating $300Electricity used: 5,151 kWhSaved vs. a minimum-efficiency heat pump: $90

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 20, 2026. How we use the data.