HVAC Rated

24,000 BTU mini-split heat pump · AURORA

Daikin RXP24AVJU

Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #407 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $666 a year to run in a mixed climate like Atlanta.

SEER2
18.3 Cooling efficiency over a season
Below average · beats 5%
HSPF2
9.2 Heating efficiency over a season
Below average · beats 16%
EER2
10.3 Cooling efficiency on a 95°F day
Below average · beats 6%
Heat at 5°F
24,000 BTU/h100% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-32
General
BrandDaikin
Outdoor unit modelRXP24AVJU
SeriesAURORA
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceNovember 10, 2025
Last certifiedOctober 17, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.3 (range 18.3)
EER2Efficiency at 95°F outdoors10.3
Cooling capacity21,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.2
Capacity at 47°F24,000 BTU/h
Capacity at 17°F16,600 BTU/h
Capacity at 5°F24,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FDMA24AVJU at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
FDMA24AVJU DAIKIN · cold climate18.310.39.224,000217816020
Yearly running cost in 10 large cities$562-$1,619

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Daikin RXP24AVJU?
The Daikin RXP24AVJU is rated at up to 18.3 SEER2 and 10.3 EER2 for cooling and up to 9.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Daikin RXP24AVJU good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Daikin RXP24AVJU cost to run per year?
At its rated efficiency it costs about $562-$1,619 a year in electricity in large U.S. cities, depending on climate and local rates - for example $709 in Phoenix and $1,365 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Daikin RXP24AVJU?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses DAIKIN FDMA24AVJU.
What refrigerant does the Daikin RXP24AVJU use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $711/yrYou save $449/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin RXP24AVJU
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$711
Current system, per year
$1,160
You save per year
$449
Payback
17.8 years
Net after 10 years
-$3,514

Cooling $419Heating $292Electricity used: 4,447 kWhSaved vs. a minimum-efficiency heat pump: $184

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 17, 2025. How we use the data.