24,000 BTU mini-split heat pump · H-Series
Fujitsu AOU24RLXFZ
Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #402 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $690 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 8.7 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- - Not reported by the maker
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Fujitsu |
| Outdoor unit model | AOU24RLXFZ |
| Series | H-Series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2016 |
| Last certified | May 28, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 18.5) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 22,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.7 |
| Capacity at 47°F | 24,000 BTU/h |
| Capacity at 17°F | 14,100 BTU/h |
| Capacity at 5°F | - |
| COP at 5°F2.0 = twice as efficient as a space heater | - |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - FUJITSU | 18.5 | 12.5 | 8.7 | - | 6998279 |
Yearly running cost in 10 large cities
- Phoenix, AZ$719/yr
- Miami, FL$562/yr
- Houston, TX$646/yr
- Atlanta, GA$690/yr
- Los Angeles, CA$680/yr
- New York, NY$1,695/yr
- Chicago, IL$1,385/yr
- Denver, CO$1,158/yr
- Seattle, WA$717/yr
- Minneapolis, MN$1,437/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Fujitsu AOU24RLXFZ?
- The Fujitsu AOU24RLXFZ is rated at up to 18.5 SEER2 and 12.5 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Fujitsu AOU24RLXFZ good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 24,000 BTU model.
- How much does the Fujitsu AOU24RLXFZ cost to run per year?
- At its rated efficiency it costs about $562-$1,695 a year in electricity in large U.S. cities, depending on climate and local rates - for example $719 in Phoenix and $1,437 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the Fujitsu AOU24RLXFZ use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Midea MO1BS-H24B-2A · cold climate18.5 SEER2 · 9.0 HSPF2
- Arcoaire D5CMTAH27DAK · cold climate18.5 SEER2 · 8.5 HSPF2
- AproDr AAG22-24H1B · cold climate18.5 SEER2 · 9.0 HSPF2
- Midea 37MTRAQ27DA3 · cold climate18.5 SEER2 · 8.5 HSPF2
- Lennox VPC024H5M-3P · cold climate18.5 SEER2 · 10.0 HSPF2
- Hitachi RAC-DJ24WHAA · cold climate18.3 SEER2 · 10.0 HSPF2
- Friedrich FPHFR24A3A · cold climate18.5 SEER2 · 10.0 HSPF2
- York YRACDJ24WHAA · cold climate18.3 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 28, 2026. How we use the data.