4-ton central heat pump · F Series
Fujitsu FOP1548TJAZNA
Below average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #308 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,518 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 27,200 BTU/h54% of its 47°F outputExcellent · beats 99%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,200 BTU/h at 5°F.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Fujitsu |
| Also sold as | Mainline, Thermal Zone |
| Outdoor unit model | FOP1548TJAZNA |
| Series | F Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 8, 2023 |
| Last certified | June 3, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 45,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1 |
| Capacity at 47°F | 45,000-45,500 BTU/h |
| Capacity at 17°F | 30,200-33,200 BTU/h |
| Capacity at 5°F | 24,200-27,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.20-2.50 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FHRNTT4821S*ZTNA at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| FHRNTT4821S*ZTNA · cold climate | 15.2 | 11.7 | 8.1 | 24,200 | 211306302 |
| FHRNVT4821S*ZTNA · cold climate | 15.2 | 11.7 | 8.1 | 27,200 | 212507700 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Fujitsu FOP1548TJAZNA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Mainline MLP15AZ48AJ2N
- Thermal Zone TZPLAD1548AJN
Yearly running cost in 10 large cities
- Phoenix, AZ$1,708/yr
- Miami, FL$1,404/yr
- Houston, TX$1,530/yr
- Atlanta, GA$1,518/yr
- Los Angeles, CA$1,470/yr
- New York, NY$3,589/yr
- Chicago, IL$2,907/yr
- Denver, CO$2,411/yr
- Seattle, WA$1,477/yr
- Minneapolis, MN$2,981/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Fujitsu FOP1548TJAZNA?
- The Fujitsu FOP1548TJAZNA is rated at up to 15.2 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Fujitsu FOP1548TJAZNA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,200 BTU/h at 5°F with a COP of 2.50, so it is still 2.5 times as efficient as electric resistance heat at that temperature.
- How much does the Fujitsu FOP1548TJAZNA cost to run per year?
- At its rated efficiency it costs about $1,404-$3,589 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,708 in Phoenix and $2,981 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Fujitsu FOP1548TJAZNA the same as the Mainline MLP15AZ48AJ2N?
- Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Fujitsu FOP1548TJAZNA?
- ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use FHRNTT4821S*ZTNA, FHRNVT4821S*ZTNA.
- What refrigerant does the Fujitsu FOP1548TJAZNA use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Friedrich FWP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Rheem RP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Friedrich FRP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Rheem WP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
- Ameristar E4HL5060A1000A · cold climate15.2 SEER2 · 8.1 HSPF2
- Samsung AC048FCUDCG · cold climate15.2 SEER2 · 8.1 HSPF2
- AC Pro BH714S48P-**A15.2 SEER2 · 8.1 HSPF2
- Sure SP15AZ48AJ2N · cold climate15.2 SEER2 · 8.1 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.