HVAC Rated

18,000 BTU mini-split heat pump · IDU Series

Kepler ODUMOX430-17HFN1MT0W

Below average cooling efficiency and very good heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #273 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $419 a year to run in a mixed climate like Atlanta.

SEER2
21.5 Cooling efficiency over a season
Below average · beats 39%
HSPF2
11.3 Heating efficiency over a season
Very good · beats 81%
EER2
12.5 Cooling efficiency on a 95°F day
Average · beats 44%
Heat at 5°F
18,000 BTU/h100% of its 47°F output
Below average · beats 20%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 81% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications18,000 BTU, R-410A
General
BrandKepler
Outdoor unit modelODUMOX430-17HFN1MT0W
SeriesIDU Series
TypeMini-split heat pump
Nominal size18,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 20, 2024
Last certifiedJune 13, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.5 (range 18.0-21.5)
EER2Efficiency at 95°F outdoors11.7-12.5
Cooling capacity16,000-18,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5-11.3
Capacity at 47°F17,000-19,000 BTU/h
Capacity at 17°F15,000-15,600 BTU/h
Capacity at 5°F16,000-18,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.85
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with IDUMSEPC-18HRFN1MU0W at the standard test temperatures, in BTU/h:

Certified matchups3 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
IDUMSEPC-18HRFN1MU0W · cold climate21.512.511.318,000213608175
IDUCCA3U-18HRFN1-M(C) · cold climate20.012.59.516,000214377773
IDUMTIU-18HWFN1-M · cold climate18.011.79.517,700214377769
Yearly running cost in 10 large cities$372-$1,004

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Kepler ODUMOX430-17HFN1MT0W?
The Kepler ODUMOX430-17HFN1MT0W is rated at up to 21.5 SEER2 and 12.5 EER2 for cooling and up to 11.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 18.0-21.5.
Is the Kepler ODUMOX430-17HFN1MT0W good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,000 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Kepler ODUMOX430-17HFN1MT0W cost to run per year?
At its rated efficiency it costs about $372-$1,004 a year in electricity in large U.S. cities, depending on climate and local rates - for example $460 in Phoenix and $840 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Kepler ODUMOX430-17HFN1MT0W?
ENERGY STAR lists 3 certified combinations for this outdoor unit. The highest-rated ones use IDUMSEPC-18HRFN1MU0W, IDUCCA3U-18HRFN1-M(C), IDUMTIU-18HWFN1-M.
What refrigerant does the Kepler ODUMOX430-17HFN1MT0W use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $457/yrYou save $436/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Kepler ODUMOX430-17HFN1MT0W
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$457
Current system, per year
$893
You save per year
$436
Payback
14.9 years
Net after 10 years
-$2,138

Cooling $278Heating $178Electricity used: 2,855 kWhSaved vs. a minimum-efficiency heat pump: $231

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 18,000 BTU models

See all 465 18,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.