2.5-ton central heat pump · MERIT ML17XP1 Series
Lennox ML17XP1-030-230A
Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.
Ranks #120 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $893 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.2 Cooling efficiency over a seasonBelow average · beats 36%
- HSPF2
- 8.6 Heating efficiency over a seasonAverage · beats 45%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 15,400 BTU/h49% of its 47°F outputExcellent · beats 94%
A good fit if…
- You want a choice of indoor units - 503 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Outdoor unit model | ML17XP1-030-230A |
| Series | MERIT ML17XP1 Series |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 6, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.2 (range 15.2-16.2) |
| EER2Efficiency at 95°F outdoors | 12.2-13.5 |
| Cooling capacity | 28,200-30,600 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.6 |
| Capacity at 47°F | 26,600-30,000 BTU/h |
| Capacity at 17°F | 17,200-19,600 BTU/h |
| Capacity at 5°F | 13,200-15,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.96-2.38 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CRX35-42B-**-*+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 503 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CRX35-42B-**-*+TDR | ML180DF090E48B* | 16.2 | 13.5 | 8.6 | 14,800 | 213257997 |
| CK40DT-42B-0*+TDR | ML180DF090E48B* | 16.2 | 13.5 | 8.6 | 14,800 | 214623711 |
| C35-36B+TDR+TXV | ML180UH070V36B* | 16.2 | 13.0 | 8.1 | 14,500 | 210046884 |
| C35-36B+TDR+TXV | ML180UH090E48B* | 16.2 | 13.0 | 8.1 | 14,100 | 210046887 |
| C35-36B+TDR+TXV | EL280UH090XE48B* | 16.2 | 13.0 | 8.1 | 14,100 | 210046875 |
| CX35-36B+TDR | ML180UH070V48B* | 16.2 | 13.0 | 8.1 | 14,400 | 210047251 |
| CX35-36B+TDR | EL280UH090E36B* | 16.2 | 13.0 | 8.1 | 14,300 | 210047242 |
| C35-36B+TDR+TXV | EL280UH090E48B* | 16.2 | 13.0 | 8.1 | 14,100 | 210046873 |
| C35-36B+TDR+TXV | SL280UH090V36B* | 16.2 | 13.0 | 8.1 | 14,500 | 210046906 |
| C35-36B+TDR+TXV | EL280UH090E36B* | 16.2 | 13.0 | 8.1 | 14,300 | 210046872 |
| CX35-36B+TDR | SL280UH080NV48B* | 16.2 | 13.0 | 8.1 | 14,500 | 210047266 |
| CX35-36B+TDR | ML180UH090E48B* | 16.2 | 13.0 | 8.1 | 14,100 | 210047252 |
| CX35-36A+TDR | SL280UH060NV36A* | 16.2 | 13.0 | 8.1 | 14,500 | 210047232 |
| CX35-36B+TDR | EL280UH090E48B* | 16.2 | 13.0 | 8.1 | 14,100 | 210047243 |
| C35-36A+TDR+TXV | SL280UH060NV36A* | 16.2 | 13.0 | 8.1 | 14,500 | 210046851 |
| CX35-36B+TDR | EL280UH090XE48B* | 16.2 | 13.0 | 8.1 | 14,100 | 210047244 |
| C35-36B+TDR+TXV | SL280UH080NV48B* | 16.2 | 13.0 | 8.1 | 14,500 | 210046905 |
| CX35-36B+TDR | ML180UH070V36B* | 16.2 | 13.0 | 8.1 | 14,500 | 210047250 |
| C35-36B+TDR+TXV | ML180UH070V48B* | 16.2 | 13.0 | 8.1 | 14,400 | 210046886 |
| CX35-36B+TDR | SL280UH090V36B* | 16.2 | 13.0 | 8.1 | 14,500 | 210047267 |
| CX35-36B+TDR | ML180UH090XE48B* | 16.2 | 13.0 | 8.1 | 14,100 | 212945077 |
| C35-36B+TDR+TXV | ML180UH090XE48B* | 16.2 | 13.0 | 8.1 | 14,100 | 212945069 |
| CK40CT-36A-0*+TDR | SL280UH060NV36A* | 16.2 | 13.0 | 8.1 | 14,500 | 214623784 |
| CK40CT-36B-0*+TDR | EL280UH090E36B* | 16.2 | 13.0 | 8.1 | 14,300 | 214623794 |
| CK40CT-36B-0*+TDR | EL280UH090E48B* | 16.2 | 13.0 | 8.1 | 14,100 | 214623795 |
| CK40CT-36B-0*+TDR | EL280UH090XE48B* | 16.2 | 13.0 | 8.1 | 14,100 | 214623796 |
| CK40CT-36B-0*+TDR | ML180UH070V36B* | 16.2 | 13.0 | 8.1 | 14,500 | 214623802 |
| CK40CT-36B-0*+TDR | ML180UH070V48B* | 16.2 | 13.0 | 8.1 | 14,400 | 214623803 |
| CK40CT-36B-0*+TDR | ML180UH090XE48B* | 16.2 | 13.0 | 8.1 | 14,100 | 214623807 |
| CK40CT-36B-0*+TDR | ML180UH090E48B* | 16.2 | 13.0 | 8.1 | 14,100 | 214623805 |
| CK40CT-36B-0*+TDR | SL280UH080NV48B* | 16.2 | 13.0 | 8.1 | 14,500 | 214623817 |
| CK40CT-36B-0*+TDR | SL280UH090V36B* | 16.2 | 13.0 | 8.1 | 14,500 | 214623818 |
| CHX35-30B-**-*+TDR | EL280UH090E36B* | 16.2 | 13.0 | 8.0 | 13,500 | 210869855 |
| CHX35-30B-**-*+TDR | ML180UH070V48B* | 16.2 | 13.0 | 8.0 | 13,700 | 210869864 |
| CHX35-30B-**-*+TDR | ML180UH070V36B* | 16.2 | 13.0 | 8.0 | 13,700 | 210869863 |
| CHX35-30B-**-*+TDR | SL280UH080NV48B* | 16.2 | 13.0 | 8.0 | 13,800 | 210869876 |
| CHX35-30B-**-*+TDR | SL280UH090V36B* | 16.2 | 13.0 | 8.0 | 13,800 | 210869877 |
| CK40HT-30B-0*+TDR | EL280UH090E36B* | 16.2 | 13.0 | 8.0 | 13,500 | 214623632 |
| CK40HT-30B-0*+TDR | ML180UH070V36B* | 16.2 | 13.0 | 8.0 | 13,700 | 214623640 |
| CK40HT-30B-0*+TDR | ML180UH070V48B* | 16.2 | 13.0 | 8.0 | 13,700 | 214623641 |
| CK40HT-30B-0*+TDR | SL280UH080NV48B* | 16.2 | 13.0 | 8.0 | 13,800 | 214623655 |
| CK40HT-30B-0*+TDR | SL280UH090V36B* | 16.2 | 13.0 | 8.0 | 13,800 | 214623656 |
| CHX35-30B-**-*+TDR | EL280UH090E48B* | 16.2 | 13.0 | 7.8 | 13,400 | 210869856 |
| CHX35-30B-**-*+TDR | EL280UH090XE48B* | 16.2 | 13.0 | 7.8 | 13,400 | 210869857 |
| CHX35-30B-**-*+TDR | ML180UH070E36B* | 16.2 | 13.0 | 7.8 | 13,400 | 210869862 |
| CHX35-30B-**-*+TDR | ML180UH090E48B* | 16.2 | 13.0 | 7.8 | 13,400 | 210869865 |
| CHX35-30B-**-*+TDR | ML180UH090XE48B* | 16.2 | 13.0 | 7.8 | 13,400 | 212945113 |
| CHX35-30B-**-*+TDR | ML180UH070XE36B* | 16.2 | 13.0 | 7.8 | 13,400 | 212945112 |
| CK40HT-30B-0*+TDR | EL280UH090XE48B* | 16.2 | 13.0 | 7.8 | 13,400 | 214623634 |
| CK40HT-30B-0*+TDR | EL280UH090E48B* | 16.2 | 13.0 | 7.8 | 13,400 | 214623633 |
| CK40HT-30B-0*+TDR | ML180UH070E36B* | 16.2 | 13.0 | 7.8 | 13,400 | 214623639 |
| CK40HT-30B-0*+TDR | ML180UH070XE36B* | 16.2 | 13.0 | 7.8 | 13,400 | 214623642 |
| CK40HT-30B-0*+TDR | ML180UH090E48B* | 16.2 | 13.0 | 7.8 | 13,400 | 214623643 |
| CK40HT-30B-0*+TDR | ML180UH090XE48B* | 16.2 | 13.0 | 7.8 | 13,400 | 214623645 |
| CBA38MV-030-230*+TDR | - | 16.0 | 13.0 | 8.5 | 15,000 | 210046918 |
| CBK45UHET-036-230-0 | - | 16.0 | 12.5 | 8.5 | 13,200 | 214861285 |
| CX35-36A+TDR | ML180UH045V36A* | 16.0 | 13.0 | 8.1 | 14,400 | 210047227 |
| C35-30A+TDR+TXV | SL280UH060NV36A* | 16.0 | 13.0 | 8.1 | 14,300 | 210046754 |
| C35-30B+TDR+TXV | SL280UH090V36B* | 16.0 | 13.0 | 8.1 | 14,300 | 210046814 |
| CX35-36A+TDR | ML180UH070XE36A* | 16.0 | 13.0 | 8.1 | 14,400 | 210047231 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,019/yr
- Miami, FL$844/yr
- Houston, TX$912/yr
- Atlanta, GA$893/yr
- Los Angeles, CA$862/yr
- New York, NY$2,097/yr
- Chicago, IL$1,695/yr
- Denver, CO$1,403/yr
- Seattle, WA$858/yr
- Minneapolis, MN$1,734/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox ML17XP1-030-230A?
- The Lennox ML17XP1-030-230A is rated at up to 16.2 SEER2 and 13.5 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 503 certified matchups SEER2 ranges from 15.2-16.2.
- Is the Lennox ML17XP1-030-230A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
- How much does the Lennox ML17XP1-030-230A cost to run per year?
- At its rated efficiency it costs about $844-$2,097 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,019 in Phoenix and $1,734 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Lennox ML17XP1-030-230A?
- ENERGY STAR lists 503 certified combinations for this outdoor unit. The highest-rated ones use CRX35-42B-**-*+TDR, CK40DT-42B-0*+TDR, C35-36B+TDR+TXV.
- What refrigerant does the Lennox ML17XP1-030-230A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- MRCOOL MHP17L30P-**A16.2 SEER2 · 8.6 HSPF2
- GE NS17H30SA4-**A16.2 SEER2 · 8.6 HSPF2
- MRCOOL MVP-30-HP-C-230A00-O16.2 SEER2 · 8.4 HSPF2
- Concord 4HP17L30P-**A16.2 SEER2 · 8.6 HSPF2
- MRCOOL MHP17030A-**A16.2 SEER2 · 8.1 HSPF2
- Comfort-Aire HRG1530S1R-**A16.2 SEER2 · 8.6 HSPF2
- Bosch BOVA-36HDN1-M15G · cold climate16.1 SEER2 · 9.0 HSPF2
- Blueridge BHP17L30P-**A16.2 SEER2 · 8.6 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.