24,000 BTU mini-split heat pump · MSAB series
MDV MOD31-23HFN1-MT2Q1W
Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #314 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $670 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.5 Cooling efficiency over a seasonBelow average · beats 24%
- HSPF2
- 9.2 Heating efficiency over a seasonBelow average · beats 16%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 18,100 BTU/h62% of its 47°F outputVery good · beats 84%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,100 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | ECO-AIR, Alsetria |
| Outdoor unit model | MOD31-23HFN1-MT2Q1W |
| Series | MSAB series |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 12, 2022 |
| Last certified | June 3, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.5 (range 16.7-20.5) |
| EER2Efficiency at 95°F outdoors | 11.7-12.5 |
| Cooling capacity | 23,000-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.1-9.2 |
| Capacity at 47°F | 24,000-25,000 BTU/h |
| Capacity at 17°F | 17,900-18,000 BTU/h |
| Capacity at 5°F | 15,500-18,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.04-2.29 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MSABE-23HRFN1-MT2Q1W at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MSABE-23HRFN1-MT2Q1W | 20.5 | 12.5 | 9.2 | 15,500 | 207338222 |
| MSABE-23HRFN1-MT2Q1W ECO-AIR | 20.5 | 12.5 | 9.2 | 15,500 | 208121857 |
| MSABE-23HRFN1-MT2Q1W Alsetria | 20.5 | 12.5 | 9.2 | 15,500 | 208121894 |
| MVC-23HWFN1-MQ1W · cold climate | 16.7 | 11.7 | 9.1 | 18,100 | 207785323 |
Yearly running cost in 10 large cities
- Phoenix, AZ$687/yr
- Miami, FL$531/yr
- Houston, TX$618/yr
- Atlanta, GA$670/yr
- Los Angeles, CA$662/yr
- New York, NY$1,658/yr
- Chicago, IL$1,357/yr
- Denver, CO$1,137/yr
- Seattle, WA$705/yr
- Minneapolis, MN$1,410/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOD31-23HFN1-MT2Q1W?
- The MDV MOD31-23HFN1-MT2Q1W is rated at up to 20.5 SEER2 and 12.5 EER2 for cooling and up to 9.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 16.7-20.5.
- Is the MDV MOD31-23HFN1-MT2Q1W good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,100 BTU/h at 5°F with a COP of 2.29, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOD31-23HFN1-MT2Q1W cost to run per year?
- At its rated efficiency it costs about $531-$1,658 a year in electricity in large U.S. cities, depending on climate and local rates - for example $687 in Phoenix and $1,410 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOD31-23HFN1-MT2Q1W?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use MSABE-23HRFN1-MT2Q1W, ECO-AIR MSABE-23HRFN1-MT2Q1W, Alsetria MSABE-23HRFN1-MT2Q1W.
- What refrigerant does the MDV MOD31-23HFN1-MT2Q1W use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- 1HVAC EZ-24ZPL-HP23020.5 SEER2 · 9.2 HSPF2
- MRCOOL DIY-24-HP-C-230C20.5 SEER2 · 9.2 HSPF2
- Hitachi RAC-SH24WHLAE20.5 SEER2 · 9.7 HSPF2
- MRCOOL DIY-24-HP-C-230C2520.5 SEER2 · 9.2 HSPF2
- Hitachi RAS-3.0PNNBDH1 · cold climate20.5 SEER2 · 10.0 HSPF2
- AIR-CON ABXCI4H4S24 · cold climate20.5 SEER2 · 8.6 HSPF2
- Goodman MST273G22MHAA · cold climate20.5 SEER2 · 10.0 HSPF2
- Friedrich FPHSR24A3A · cold climate20.5 SEER2 · 8.6 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.