18,000 BTU mini-split heat pump · YN series
Pioneer YN018GMFI22RPE
Average cooling and heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #138 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $463 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.0 Cooling efficiency over a seasonAverage · beats 62%
- HSPF2
- 10.7 Heating efficiency over a seasonAverage · beats 68%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 13,100 BTU/h65% of its 47°F outputExcellent · beats 93%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 13,100 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Pioneer |
| Outdoor unit model | YN018GMFI22RPE |
| Series | YN series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2022 |
| Last certified | May 6, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.0 (range 20.0-23.0) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 16,000-18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0-10.7 |
| Capacity at 47°F | 17,000-20,000 BTU/h |
| Capacity at 17°F | 12,000-13,400 BTU/h |
| Capacity at 5°F | 12,700-13,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.08-2.40 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with UB018GMFILCFHD at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| UB018GMFILCFHD PIONEER | 23.0 | 12.5 | 10.0 | 13,000 | 208141956 |
| UB018GMFILCFHD PIONEER | 23.0 | 12.5 | 10.0 | 13,000 | 208141956 |
| FB018GMFILDFHE PIONEER · cold climate | 22.4 | 12.5 | 10.4 | 12,700 | 213349747 |
| CK018GMFILCFHD PIONEER | 21.8 | 12.5 | 10.7 | 13,100 | 213349744 |
| CB018GMFILCFHD PIONEER | 20.5 | 12.5 | 10.5 | 12,700 | 208191863 |
| RB018GMFILDFHD PIONEER | 20.0 | 12.5 | 10.6 | 13,000 | 208141953 |
Yearly running cost in 10 large cities
- Phoenix, AZ$478/yr
- Miami, FL$370/yr
- Houston, TX$429/yr
- Atlanta, GA$463/yr
- Los Angeles, CA$457/yr
- New York, NY$1,143/yr
- Chicago, IL$935/yr
- Denver, CO$783/yr
- Seattle, WA$485/yr
- Minneapolis, MN$971/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Pioneer YN018GMFI22RPE?
- The Pioneer YN018GMFI22RPE is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 10.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 20.0-23.0.
- Is the Pioneer YN018GMFI22RPE good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 13,100 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
- How much does the Pioneer YN018GMFI22RPE cost to run per year?
- At its rated efficiency it costs about $370-$1,143 a year in electricity in large U.S. cities, depending on climate and local rates - for example $478 in Phoenix and $971 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Pioneer YN018GMFI22RPE?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use PIONEER UB018GMFILCFHD, PIONEER FB018GMFILDFHE, PIONEER CK018GMFILCFHD.
- What refrigerant does the Pioneer YN018GMFI22RPE use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- ComfortStar CZP18CD(O)23.0 SEER2 · 10.7 HSPF2
- Lennox LISH018000P431-D23.0 SEER2 · 10.6 HSPF2
- GE Appliances ASH118URDSE23.0 SEER2 · 11.0 HSPF2
- Lennox MMLD020S6M-1P · cold climate23.0 SEER2 · 10.5 HSPF2
- GE Appliances ASH118URDE · cold climate23.0 SEER2 · 12.0 HSPF2
- MDV MOX430-18HFN1-MT2Q1W23.0 SEER2 · 10.3 HSPF2
- AUX ASUM18HPMULO · cold climate23.3 SEER2 · 11.0 HSPF2
- MRCOOL DIY-18-HP-C-230C2523.0 SEER2 · 10.3 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 6, 2026. How we use the data.