HVAC Rated

3-ton central heat pump · A5HP5

RunTru A5HP5036A1

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #232 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,024 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
17,800 BTU/h55% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want a choice of indoor units - 296 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandRunTru
Also sold asAmeristar
Outdoor unit modelA5HP5036A1
SeriesA5HP5
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 19, 2024
Last certifiedMarch 26, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity32,000-35,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F29,800-32,800 BTU/h
Capacity at 17°F20,800-22,400 BTU/h
Capacity at 5°F16,700-17,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5PX*C007AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups296 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 296 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5PX*C007AS3+TSTATA952V100CU5SB16.012.08.517,600215575108
5PX*C007AS3+TSTATA952V100CU5SB16.012.08.517,600215575109
5TXCC007AS3+TSTATA952V100CU5SA16.012.08.117,400214296485
5TXCC007AS3+TSTATA952V100CU5SA16.012.08.117,400214296484
5TXCC007AS3+TSTATA952V100CU5SB16.012.08.117,400214296486
5TXCC007AS3+TSTATA952V100CU5SB16.012.08.117,400214296487
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.117,400214296493
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.117,400214296492
A5AHV004A1D3+TDR+TSTAT-16.012.08.117,500214296500
A5AHV004A1D3+TDR+TSTAT-16.012.08.117,500214296501
A5AHV006A1D3+TDR+TSTAT-16.012.08.117,800214296502
A5AHV007A1D3+TDR+TSTAT-16.012.08.117,600214296504
A5AHV006A1D3+TDR+TSTAT-16.012.08.117,800214296503
A5AHV007A1D3+TDR+TSTAT-16.012.08.117,600214296505
5PX*CD07AS3+TSTATA801X080CM5SD16.012.08.117,700215575146
5PX*CD07AS3+TSTATA801X080CM5SD16.012.08.117,700215575147
5PX*CD07AS3+TSTATA801X080CM5TD16.012.08.117,700215575148
5PX*CD07AS3+TSTATA801X080CM5TD16.012.08.117,700215575149
5PX*CD09AS3+TSTATA801X080CM5SD16.012.08.117,400215575156
5PX*CD09AS3+TSTATA801X080CM5SD16.012.08.117,400215575157
5PX*CD09AS3+TSTATA801X080CM5TD16.012.08.117,400215575158
5PX*CD09AS3+TSTATA801X080CM5TD16.012.08.117,400215575159
5PX*CD09AS3+TSTAT+P0V0C000M50SD-16.012.08.117,300215575160
5PX*CD09AS3+TSTAT+P0V0C000M50SD-16.012.08.117,300215575161
5PX*C007AS3+TSTATL8V1C100U5VSB16.012.08.117,500215575098
5PX*C007AS3+TSTATL8V1C100U5VSB16.012.08.117,500215575099
5PX*C007AS3+TSTATA951X080CU5SA16.012.08.117,400215575100
5PX*C007AS3+TSTATA951X080CU5SA16.012.08.117,400215575101
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.117,300215575102
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.117,300215575103
5PX*C007AS3+TSTATA801X080CM5SD16.012.08.117,500215575110
5PX*C007AS3+TSTATA801X080CM5SD16.012.08.117,500215575111
5PX*C007AS3+TSTATA801X080CM5TD16.012.08.117,500215575112
5PX*C007AS3+TSTATA801X080CM5TD16.012.08.117,500215575113
5PX*C009AS3+TSTATA951X080CU5SA16.012.08.117,200215575117
5PX*C009AS3+TSTATA951X080CU5SA16.012.08.117,200215575116
5PX*C009AS3+TSTATA801X080CM5SD16.012.08.117,400215575118
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.117,500215575014
5PX*B006AS3+TSTAT+P0V0B000M40SD-16.012.08.117,500215575015
5PX*BD06AS3+TSTAT+P0V0B000M40SD-16.012.08.117,700215575054
5PX*BD06AS3+TSTAT+P0V0B000M40SD-16.012.08.117,700215575055
5PX*C009AS3+TSTATA801X080CM5SD16.012.08.117,400215575119
5PX*C009AS3+TSTATA801X080CM5TD16.012.08.117,400215575120
5PX*C009AS3+TSTATA801X080CM5TD16.012.08.117,400215575121
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.012.08.117,200215575124
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.012.08.117,200215575125
5PX*C009AS3+TSTATL8V1C100U5VSB16.012.08.117,200215575126
5PX*C009AS3+TSTATL8V1C100U5VSB16.012.08.117,200215575127
5PX*C009AS3+TSTATA952V100CU5SB16.012.08.117,100215575132
5PX*C009AS3+TSTATA952V100CU5SB16.012.08.117,100215575133
5PX*CD07AS3+TSTAT+P0V0C000M50SD-16.012.08.117,500215575144
5PX*CD07AS3+TSTAT+P0V0C000M50SD-16.012.08.117,500215575145
5TXCC009AS3+TSTATA801X080CM5SD16.012.08.117,400215575224
5TXCC009AS3+TSTATA801X080CM5SD16.012.08.117,400215575225
A5AHV005A1D3+TDR+TSTAT-16.012.08.117,500215611096
A5AHV005A1D3+TDR+TSTAT-16.012.08.117,500215611097
5TXCC009AS3+TSTATA801X080CM5TD16.012.08.117,400215575226
5TXCC009AS3+TSTATA801X080CM5TD16.012.08.117,400215575227
5TXCC009AS3+TSTATA951X080CU5SA16.012.08.117,200215575228
5TXCC009AS3+TSTATA951X080CU5SA16.012.08.117,200215575229
Yearly running cost in 10 large cities$975-$2,392

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the RunTru A5HP5036A1?
The RunTru A5HP5036A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 296 certified matchups SEER2 ranges from 15.2-16.0.
Is the RunTru A5HP5036A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the RunTru A5HP5036A1 cost to run per year?
At its rated efficiency it costs about $975-$2,392 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,179 in Phoenix and $1,973 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the RunTru A5HP5036A1?
ENERGY STAR lists 296 certified combinations for this outdoor unit. The highest-rated ones use 5PX*C007AS3+TSTAT, 5TXCC007AS3+TSTAT, A5AHV004A1D3+TDR+TSTAT.
What refrigerant does the RunTru A5HP5036A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,153/yrYou save $544/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump RunTru A5HP5036A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,153
Current system, per year
$1,697
You save per year
$544
Payback
23.0 years
Net after 10 years
-$7,064

Cooling $739Heating $414Electricity used: 7,206 kWhSaved vs. a minimum-efficiency heat pump: $143

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 26, 2026. How we use the data.