HVAC Rated

2.5-ton central heat pump · VANTIX

Sure SP15AZ30AJ2N

Below average cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.

Ranks #141 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $929 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
16,100 BTU/h55% of its 47°F output
Very good · beats 76%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 16,100 BTU/h at 5°F.
  • You want a choice of indoor units - 49 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandSure
Also sold asRUSSELL
Outdoor unit modelSP15AZ30AJ2N
SeriesVANTIX
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 27, 2023
Last certifiedJuly 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity27,800-28,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F27,800-28,400 BTU/h
Capacity at 17°F18,500-20,200 BTU/h
Capacity at 5°F14,400-16,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.20
ENERGY STAR cold climateYes
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SH2VZ3617STANN at the standard test temperatures, in BTU/h:

Certified matchups49 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
SH2VZ3617STANN · cold climate-16.011.78.115,600212381140
SH2VZ3617STANN · cold climate-16.011.78.115,600212381147
TCFZ3617STANM · cold climateS962V0603A17M4S15.211.78.116,100212387265
TCFZ3617STANM · cold climateS962V0403A17M4S15.211.78.116,000212387260
TCFZ3617STANM · cold climateS962V0603A17M4S15.211.78.116,100212387264
TCFZ3617STANM · cold climateS962V0703A17M4S15.211.78.115,900212387270
TCFZ3617STANM · cold climateS951V0703A17M4S15.211.78.115,900212387256
TCFZ3617STANM · cold climateS951V0603A17M4S15.211.78.116,100212387252
TCFZ3617STANM · cold climateS951V0703A17M4S15.211.78.115,900212387257
TCFZ3617STANM · cold climateS951V0603A17M4S15.211.78.116,100212387253
TCFZ3617STANM · cold climateS962V0403A17M4S15.211.78.116,000212387261
TCFZ3617STANMS801V0504A17UH15.211.78.1-212387139
TCFZ3617STANM · cold climateS962V0703A17M4S15.211.78.115,900212387271
TCFZ3617STANMS96VA0602317M15.211.78.1-212387279
TCFZ3617STANMS96VA0602317M15.211.78.1-212387278
TCFZ3621STANM · cold climateS962V0703A17M4S15.211.78.115,900213244137
TCFZ3621STANM · cold climateS98MV0603A17UPS15.211.78.115,800213244142
TCFZ3621STANM · cold climateS98MV0603A17UPS15.211.78.115,800213244143
TCFZ3621STANM · cold climateS962V0703A17M4S15.211.78.115,900213244136
TCFZ3621STANM · cold climateS951V0403A17M4S15.211.78.116,000213244127
TCFZ3621STANM · cold climateS962V0603A17M4S15.211.78.116,100213244134
TCFZ3621STANM · cold climateS951V0703A17M4S15.211.78.115,900213244131
TCFZ3621STANM · cold climateS951V0603A17M4S15.211.78.116,100213244128
TCFZ3621STANM · cold climateS962V0403A17M4S15.211.78.116,000213244133
TCFZ3621STANM · cold climateS951V0403A17M4S15.211.78.116,000213244126
TCFZ3621STANM · cold climateS951V0603A17M4S15.211.78.116,100213244129
TCFZ3621STANM · cold climateS962V0403A17M4S15.211.78.116,000213244132
TCFZ3621STANM · cold climateS962V0603A17M4S15.211.78.116,100213244135
TCFZ3621STANM · cold climateS951V0703A17M4S15.211.78.115,900213244130
TCFZ3617STANM · cold climateS98MV0703A17UPS15.211.78.115,800212941659
TCFZ3617STANM · cold climateS98MV0703A17UPS15.211.78.115,800212941644
TCFZ3617STANM · cold climateS98MV0603A17UPS15.211.78.115,800212387331
TCFZ3617STANM · cold climateS98MV0603A17UPS15.211.78.115,800212387332
TCFZ3617STANM · cold climateS951V0403A17M4S15.211.78.116,000212387242
TCFZ3617STANM · cold climateS951V0403A17M4S15.211.78.116,000212387241
SH2CZ3617STANN-15.211.77.815,600211627534
SH2CZ3617STANN-15.211.77.815,600211627535
TCFZ3621STANMS98MV1005A21UPS15.211.77.814,500213243297
TCFZ3621STANMS98MV1005A21UPS15.211.77.814,500213243284
TCFZ3621STANMS962V0705A21M4S15.211.77.814,500213243302
TCFZ3621STANMS962V0705A21M4S15.211.77.814,500213243304
TCFZ3621STANMS97MV0603A17DHS15.211.77.815,800213244150
TCFZ3621STANMS97MV0603A17DHS15.211.77.815,800213244149
TCFZ3621STANMS98MV0703A17UPS15.211.77.814,400213228988
TCFZ3621STANMS98MV0703A17UPS15.211.77.814,400213228985
TCFZ3617STANMS97MV0603A17DHS15.211.77.815,800212387350
TCFZ3617STANMS97MV0603A17DHS15.211.77.815,800212387349
RF2TZ3624STANS-15.211.77.814,600212381141
RF2TZ3624STANS-15.211.77.814,600212381143
Yearly running cost in 10 large cities$834-$2,218

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Sure SP15AZ30AJ2N?
The Sure SP15AZ30AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 49 certified matchups SEER2 ranges from 15.2-16.0.
Is the Sure SP15AZ30AJ2N good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 16,100 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Sure SP15AZ30AJ2N cost to run per year?
At its rated efficiency it costs about $834-$2,218 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,026 in Phoenix and $1,852 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Sure SP15AZ30AJ2N?
ENERGY STAR lists 49 certified combinations for this outdoor unit. The highest-rated ones use SH2VZ3617STANN, TCFZ3617STANM, TCFZ3621STANM.
What refrigerant does the Sure SP15AZ30AJ2N use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,017/yrYou save $447/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Sure SP15AZ30AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,017
Current system, per year
$1,464
You save per year
$447
Payback
23.5 years
Net after 10 years
-$6,031

Cooling $625Heating $393Electricity used: 6,359 kWhSaved vs. a minimum-efficiency heat pump: $106

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 7, 2026. How we use the data.