HVAC Rated

2-ton central heat pump · XV20I

Trane 4TWV0X24A1

Excellent cooling efficiency and average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #45 of 331 2 ton central heat pumps for cooling efficiency, and costs about $633 a year to run in a mixed climate like Atlanta.

SEER2
19.5 Cooling efficiency over a season
Excellent · beats 91%
HSPF2
8.7 Heating efficiency over a season
Average · beats 47%
EER2
12.7 Cooling efficiency on a 95°F day
Very good · beats 84%
Heat at 5°F
13,400 BTU/h63% of its 47°F output
Below average · beats 27%

A good fit if…

  • You want low cooling bills - its SEER2 beats 91% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 55 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model4TWV0X24A1
SeriesXV20I
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2023
Last certifiedJuly 9, 2025
Cooling
SEER2Seasonal efficiency, higher is better19.5 (range 17.0-19.5)
EER2Efficiency at 95°F outdoors11.7-12.7
Cooling capacity22,200-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.7
Capacity at 47°F19,600-22,400 BTU/h
Capacity at 17°F16,400-17,900 BTU/h
Capacity at 5°F12,400-13,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.60-1.95
ENERGY STAR cold climateNo
Heating output as it gets colder63% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TAMXB0B30V31 at the standard test temperatures, in BTU/h:

Certified matchups55 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TAMXB0B30V31-19.512.78.712,900210929561
4TXCB004DS3*UHMB060ACV319.512.78.512,700210288157
4PX*BU36BS3*UHMB060ACV319.512.78.512,700207558947
4PX*BU36BS3S9V2B060U3VSA+RP19.512.58.513,000207526405
4PX*BU36BS3S9V2B060U3VSB+RP19.512.58.513,000214638791
4PX*BU36BS3*UHMB060CCV319.512.78.512,700214250619
4PX*BU36BS3*UHMB080CCV319.512.78.512,800214250617
4TXCB004DS3*UHMB060CCV319.512.78.512,700214250625
4TXCB003DS3*UHMB080ACV319.512.78.213,100210653459
4TXCB003DS3*UHMB060ACV319.512.78.213,100210653458
4TXCB003DS3*UHMB060CCV319.512.78.213,000214250621
4TXCB003DS3*UHMB080CCV319.512.78.213,100214250623
TEM8A0B30V31+TDR-19.012.58.713,100207526337
TEM8A0B24V21+TDR-19.012.58.713,200210636920
4PX*BU36BS3S9V2B040U3PSB+RP19.012.58.513,100207526368
4PX*BU36BS3S9V2B040U3VSA+RP19.012.58.513,100207526404
4PX*BU36BS3S9V2B040U3VSB+RP19.012.58.513,100214638793
4TXCB004DS3S9V2B040U3VSB+RP19.012.58.513,100214638797
4PX*BU36BS3S9V2B080U4PSC+RP19.012.78.512,800214639417
4TXCB004DS3S9V2B080U4PSC+RP19.012.78.512,900214639431
4TXCB004DS3S9V2B040U3PSC+RP19.012.58.512,700214639433
4TXCB003DS3S9V2B040U3VSA+RP19.012.08.213,400210653452
4TXCB003DS3S9V2B040U3PSB+RP19.012.08.213,400210653455
4TXCB003DS3S9V2B040U3VSB+RP19.012.58.213,300214638795
4PX*BU30BS3S9V2B040U3PSC+RP19.012.58.212,900214639405
4PX*BU30BS3S9V2B080U4PSC+RP19.012.58.213,100214639411
4PX*BU36BS3S9V2B060U4PSC+RP18.512.78.512,800214639415
4TXCB004DS3S9V2B060U4PSC+RP18.512.78.512,900214639429
4TXCB004DS3S9V2B060U4VSB+RP18.512.68.512,900215825675
4PX*BU30BS3S9V2B060U4PSC+RP18.512.58.213,200214639413
4TXCB003DS3S9V2B060U4PSC+RP18.512.58.213,200214639421
4TXCB003DS3S9V2B060U4VSB+RP18.512.58.213,100215825671
4TXCB004DS3L8V1A060U3VSA+RP18.012.08.212,600210653462
4PX*BU36BS3L8V1A060U3VSA+RP18.012.08.212,500210653450
4TXCB004DS3L8V1A060U3VSB+RP18.012.08.212,600212629785
4PX*BU36BS3L8V1A060U3VSB+RP18.012.08.212,500212629773
4TXCB003DS3L8V1A060U3VSA+RP18.012.08.012,900210653457
4TXCB004DS3L8V1A040U3VSA+RP17.512.08.212,600210653461
4PX*BU36BS3S8V2A040M3PCA17.512.58.212,400210691802
4TXCB004DS3S8V2A040M3PCA17.512.58.212,400210691806
4PX*BU36BS3S8V2A040M3PDA17.512.58.212,400211081171
4TXCB004DS3S8V2A040M3PDA17.512.58.212,400211081175
4TXCB004DS3L8V1A040U3VSB+RP17.512.08.212,600212629783
4TXCB004DS3S9V2B060D3PSC+RP17.511.78.212,600214639427
4PX*BU36BS3S8V2A040M3PDB17.512.58.212,400214252923
4TXCB004DS3S8V2A040M3PCB17.512.58.212,400214252941
4TXCB004DS3S8V2A040M3PDB17.512.58.212,400214252943
4PX*BU36BS3S8V2A040M3PCB17.512.58.212,400214252929
4PX*BU36BS3L8V1A040U3VSB+RP17.512.08.112,500212629771
4TXCB003DS3S8V2A040M3PCA17.512.08.012,800210691804
4TXCB003DS3S8V2A040M3PDA17.512.08.012,800211081174
4TXCB003DS3L8V1A040U3VSA+RP17.512.08.012,900210653460
4TXCB003DS3S8V2A040M3PDB17.512.08.012,800214252933
4TXCB003DS3*DD2B060ACV317.511.77.813,000211597913
4TXCB004DS3S9V2B040D3PSC+RP17.011.78.212,500214639425
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 4TWV0X24A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$569-$1,512

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 4TWV0X24A1?
The Trane 4TWV0X24A1 is rated at up to 19.5 SEER2 and 12.7 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 55 certified matchups SEER2 ranges from 17.0-19.5.
Is the Trane 4TWV0X24A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Trane 4TWV0X24A1 cost to run per year?
At its rated efficiency it costs about $569-$1,512 a year in electricity in large U.S. cities, depending on climate and local rates - for example $700 in Phoenix and $1,263 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 4TWV0X24A1 the same as the American Standard 4A6V0X24A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 4TWV0X24A1?
ENERGY STAR lists 55 certified combinations for this outdoor unit. The highest-rated ones use TAMXB0B30V31, 4TXCB004DS3, 4PX*BU36BS3.
What refrigerant does the Trane 4TWV0X24A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $694/yrYou save $477/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 4TWV0X24A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$694
Current system, per year
$1,171
You save per year
$477
Payback
18.9 years
Net after 10 years
-$4,227

Cooling $426Heating $268Electricity used: 4,336 kWhSaved vs. a minimum-efficiency heat pump: $198

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 9, 2025. How we use the data.