3.5-ton central heat pump · 20 TruComfort Variable Speed Heat Pump

Trane 5TWV0X48A1

Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #8 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,220 a year to run in a mixed climate like Atlanta.

SEER2
20.8 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
34,800 BTU/h71% of its 47°F output
Very good · beats 80%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 34,800 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model5TWV0X48A1
Series20 TruComfort Variable Speed Heat Pump
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 27, 2024
Last certifiedJune 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.8 (range 19.4-20.8)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity43,500-47,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.4-10.0
Capacity at 47°F46,000-48,000 BTU/h
Capacity at 17°F41,500-43,000 BTU/h
Capacity at 5°F32,600-34,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.22
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCD010AS3 at the standard test temperatures, in BTU/h:

Certified matchups137 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 137 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCD010AS3S9V2D120U5VSB+VCKIT20.812.09.732,800218036413
5PX*D010AS3S9V2D120U5VSB+VCKIT20.812.09.732,800218036385
5TEMCD07AV51+TDR · cold climate-20.612.010.033,400216440336
5PX*D010AS3 · cold climateL8V1C100U5VSB+LRP20.412.010.033,600216440308
5PX*D010AS3 · cold climateS8V2D120M5PCB20.412.010.033,600216453171
5PX*D010AS3 · cold climateS8V2D120M5PDB20.412.010.033,600216453175
5TXCD010AS3 · cold climateS8V2D120M5PDB20.412.010.033,600216453211
5TXCD010AS3 · cold climateS8V2D120M5PCB20.412.010.033,600216453215
5PX*D010AS3 · cold climate*UHMC100CCV4+LRP20.212.010.034,000216571108
5PX*C009AS3+P0V0C000M50SD+LRP · cold climate-20.212.09.732,800216440250
5PX*C009AS3 · cold climateL8V1C100U5VSB+LRP20.212.09.733,600216440258
5TXCC009AS3 · cold climateL8V1C100U5VSB+LRP20.212.09.733,600216440368
5TXCC009AS3+P0V0C000M50SD+LRP · cold climate-20.212.09.732,800216440372
5TXCD010AS3 · cold climateS9V2D120U5VSB+LRP20.212.09.732,800216440394
5TXCD010AS3 · cold climateS9V2D120U5PSC+LRP20.212.09.732,800216440396
5TXCD010AS3+P0V0C000M50SD+LRP · cold climate-20.212.09.732,800216440400
5TXCD010AS3 · cold climateL8V1C100U5VSB+LRP20.212.09.733,600216440412
5PX*D010AS3+P0V0D000M50SD+LRP · cold climate-20.212.09.732,800216440294
5PX*D010AS3+P0V0C000M50SD+LRP · cold climate-20.212.09.732,800216440298
5PX*D010AS3 · cold climateS9V2D120U5VSB+LRP20.212.09.732,800216440306
5PX*D010AS3 · cold climateS9V2D120U5PSC+LRP20.212.09.732,800216440310
5TAMXD06AV41 · cold climate-20.212.09.733,800216440330
5PX*C009AS3 · cold climateS9V2C080U5VSB+LRP20.012.09.733,000216440252
5PX*C009AS3 · cold climateS9V2C080U5PSC+LRP20.012.09.733,000216440254
5PX*C009AS3 · cold climateS9V2C100U5VSB+LRP20.012.09.733,000216440256
5PX*C009AS3 · cold climateS9V2C100U5PSC+LRP20.012.09.733,000216440260
5PX*C009AS3 · cold climateS9V2C100U4VSB+LRP20.012.09.733,000216440262
5TXCC009AS3 · cold climateS9V2C100U5VSB+LRP20.012.09.733,000216440360
5TXCC009AS3 · cold climateS9V2C100U4VSB+LRP20.012.09.733,000216440362
5TXCC009AS3 · cold climateS9V2C080U5PSC+LRP20.012.09.733,000216440364
5TXCC009AS3 · cold climateS9V2C100U5PSC+LRP20.012.09.733,000216440366
5TXCC009AS3 · cold climateS9V2C080U5VSB+LRP20.012.09.733,000216440370
5TXCD010AS3+P0V0D000M50SD+LRP · cold climate-20.012.09.732,600216440398
5TXCD010AS3 · cold climateS9V2C100U5VSB+LRP20.012.09.733,200216440402
5TXCD010AS3 · cold climateS9V2C080U5VSB+LRP20.012.09.733,000216440404
5TXCD010AS3 · cold climateS9V2C100U5PSC+LRP20.012.09.733,200216440406
5TXCD010AS3 · cold climateS9V2C080U5PSC+LRP20.012.09.733,000216440408
5TXCD010AS3 · cold climateS9V2C100U4VSB+LRP20.012.09.733,200216440410
5PX*D010AS3 · cold climateS9V2C100U5VSB+LRP20.012.09.733,000216440292
5PX*D010AS3 · cold climateS9V2C080U5VSB+LRP20.012.09.733,000216440296
5PX*D010AS3 · cold climateS9V2C100U5PSC+LRP20.012.09.733,000216440300
5PX*D010AS3 · cold climateS9V2C080U5PSC+LRP20.012.09.733,000216440302
5PX*D010AS3 · cold climateS9V2C100U4VSB+LRP20.012.09.733,000216440304
5PX*DD10AS3 · cold climateS9V2D120D5PSC+LRP20.012.09.732,800216440312
5PX*DD10AS3 · cold climateS9V2D120D5VSB+LRP20.012.09.732,800216440314
5PX*DD10AS3 · cold climate*DHMD120CCV5+LRP20.011.79.733,600216440318
5PX*DD10AS3+P0V0C000M50SD+LRP · cold climate-20.012.09.732,800216440322
5PX*DD10AS3+P0V0D000M50SD+LRP · cold climate-20.012.09.732,600216440324
5PX*C009AS3 · cold climateS8V2C100M5PDB20.012.09.733,800216453153
5PX*C009AS3 · cold climateS8V2C100M5PCB20.012.09.733,800216453155
5PX*D010AS3 · cold climateS8V2C100M5PDB20.012.09.733,800216453169
5PX*D010AS3 · cold climateS8V2C100M5PCB20.012.09.733,800216453173
5PX*DD10AS3 · cold climateS8V2C100M5PCB20.011.79.733,800216453177
5PX*DD10AS3 · cold climateS8V2C100M5PDB20.011.79.733,800216453179
5PX*DD10AS3 · cold climateS8V2D120M5PDB20.011.79.733,800216453181
5PX*DD10AS3 · cold climateS8V2D120M5PCB20.011.79.733,800216453183
5TXCC009AS3 · cold climateS8V2C100M5PCB20.012.09.733,800216453197
5TXCC009AS3 · cold climateS8V2C100M5PDB20.012.09.733,800216453199
5TXCD010AS3 · cold climateS8V2C100M5PDB20.012.09.733,800216453209
5TXCD010AS3 · cold climateS8V2C100M5PCB20.012.09.733,800216453213
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 5TWV0X48A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,020-$2,972

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 5TWV0X48A1?
The Trane 5TWV0X48A1 is rated at up to 20.8 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 137 certified matchups SEER2 ranges from 19.4-20.8.
Is the Trane 5TWV0X48A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 34,800 BTU/h at 5°F with a COP of 2.22, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Trane 5TWV0X48A1 cost to run per year?
At its rated efficiency it costs about $1,020-$2,972 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,292 in Phoenix and $2,509 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 5TWV0X48A1 the same as the American Standard 5A6V0X48A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 5TWV0X48A1?
ENERGY STAR lists 137 certified combinations for this outdoor unit. The highest-rated ones use 5TXCD010AS3, 5PX*D010AS3, 5TEMCD07AV51+TDR.
What refrigerant does the Trane 5TWV0X48A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,299/yrYou save $1,070/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWV0X48A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,299
Current system, per year
$2,369
You save per year
$1,070
Payback
15.9 years
Net after 10 years
-$6,297

Cooling $762Heating $538Electricity used: 8,120 kWhSaved vs. a minimum-efficiency heat pump: $525

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 12, 2026. How we use the data.