HVAC Rated

3.5-ton central heat pump · 15 Single-Stage Heat Pump with WeatherGuard Top

Trane 5TWX5042A1

Average cooling efficiency and below average heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #55 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,245 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
20,000 BTU/h49% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 231 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX5042A1
Series15 Single-Stage Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 1, 2024
Last certifiedJune 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity38,000-41,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F38,500-40,000 BTU/h
Capacity at 17°F25,000-26,200 BTU/h
Capacity at 5°F18,700-20,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCD008AS3+TSTAT+P0V0D000M50SD at the standard test temperatures, in BTU/h:

Certified matchups231 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 231 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCD008AS3+TSTAT+P0V0D000M50SD-16.512.08.119,200215687470
5PX*D008AS3+TSTAT+P0V0D000M50SD-16.512.08.119,200215687375
5PX*D010AS3+TSTATS9V2D120U5PSC16.512.08.119,400215687386
5PX*D010AS3+TSTAT+P0V0D000M50SD-16.512.08.119,100215687387
5PX*D010AS3+TSTATS9V2D120U5VSB16.512.08.119,400215687392
5TEMCD06AV41+TDR+TSTAT-16.512.08.118,700215863981
5TEMCD07AV51+TDR+TSTAT-16.512.08.118,700215863982
5TXCD010AS3+TSTAT+P0V0D000M50SD-16.512.08.018,800214182925
5TEM6D07AV51+TDR+TSTAT-16.012.08.519,700214182698
5TXCD010AS3+TSTATS8V2D120M5PCA16.012.08.119,100214182923
5TXCD010AS3+TSTAT*UHMD120ACV516.012.08.119,000214182931
5TXCD010AS3+TSTATS9V2D120U5VSB16.012.08.118,900214182935
5TXCD010AS3+TSTATS9V2D120U5VSA16.012.08.118,900214182937
5TXCD010AS3+TSTATS9V2D120U5PSC16.012.08.119,000214182939
5TXCD010AS3+TSTATS9V2D120U5PSB16.012.08.118,900214182941
5TXCD010AS3+TSTATS8X2D120M5PTC16.012.08.119,100214182943
5TXCD010AS3+TSTATS8X1D120M5PSC16.012.08.119,100214182949
5TXCD010AS3+TSTATS8V2D120M5PDA16.012.08.119,100214182947
5TXCD010AS3+TSTATS8X2D120M5PSC16.012.08.119,100214182953
5TXCD010AS3+TSTATS8X1D120M5PTC16.012.08.119,100214182955
5TEM6D06AV41+TDR+TSTAT-16.012.08.119,300214182696
5TXCC009AS3+TSTATS9X2C080U5PSB16.012.08.119,600215687449
5TXCC009AS3+TSTATS8X2C100M5PSC16.012.08.119,300215687451
5TXCC009AS3+TSTATS8X2C080M5PSC16.012.08.119,200215687452
5TXCC009AS3+TSTAT*UHMC100CCV416.012.08.119,100215687454
5TXCC009AS3+TSTATL8V1C100U5VSB16.012.08.119,500215687453
5TXCC009AS3+TSTATS9X1C080U5PSB16.012.08.119,600215687455
5TXCC009AS3+TSTATS8X2C100M5PTC16.012.08.119,300215687456
5TXCC009AS3+TSTATS9V2C080U5PSC16.012.08.119,300215687457
5TXCC009AS3+TSTATS9V2C100U4VSB16.012.08.119,200215687458
5TXCC009AS3+TSTATS9V2C100U5PSC16.012.08.119,200215687459
5TXCD008AS3+TSTATS9V2D120U5PSC16.012.08.119,200215687464
5TXCD008AS3+TSTATS8X2D120M5PTC16.012.08.119,400215687465
5TXCD008AS3+TSTATS8X2D120M5PSC16.012.08.119,400215687466
5TXCD008AS3+TSTATS8X1D120M5PTC16.012.08.119,400215687467
5TXCD008AS3+TSTATS8X1D120M5PSC16.012.08.119,400215687468
5TXCD008AS3+TSTATS8V2D120M5PCB16.012.08.119,400215687469
5TXCD008AS3+TSTAT*UHMD120CCV516.012.08.119,500215687472
5TXCD008AS3+TSTATS9X2D120U5PSB16.012.08.119,300215687473
5TXCD008AS3+TSTATS9V2D120U5VSB16.012.08.119,200215687474
5TXCD008AS3+TSTATS9X1D120U5PSB16.012.08.119,300215687475
5TXCC009AS3+TSTATS8X2C080M5PTC16.012.08.119,200215687436
5TXCC009AS3+TSTATS8X1C100M5PTC16.012.08.119,300215687438
5TXCC009AS3+TSTATS8X1C100M5PSC16.012.08.119,300215687439
5TXCC009AS3+TSTATS8X1C080M5PTC16.012.08.119,200215687440
5TXCC009AS3+TSTATS8V2C100M5PDB16.012.08.119,300215687442
5TXCC009AS3+TSTATS8V2C100M5PCB16.012.08.119,300215687443
5TXCC009AS3+TSTATS8X1C080M5PSC16.012.08.119,200215687441
5TXCC009AS3+TSTATS8V2C080M5PDB16.012.08.119,300215687444
5TXCC009AS3+TSTATS8V2C080M5PCB16.012.08.119,300215687445
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.012.08.119,000215687446
5PX*C007AS3+TSTATS8X2C100M5PSC16.012.08.119,700215687282
5PX*C007AS3+TSTATS9V2C100U5PSC16.012.08.119,700215687283
5PX*C007AS3+TSTATS8X2C080M5PSC16.012.08.119,700215687284
5PX*C007AS3+TSTATS8X1C100M5PTC16.012.08.119,700215687285
5PX*C007AS3+TSTATS8X1C080M5PTC16.012.08.119,700215687287
5PX*C007AS3+TSTATS8X1C100M5PSC16.012.08.119,700215687286
5PX*C007AS3+TSTATS8X1C080M5PSC16.012.08.119,700215687288
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.012.08.119,200215687293
5PX*C007AS3+TSTATL8V1C100U5VSB16.012.08.119,600215687296
Yearly running cost in 10 large cities$1,138-$2,957

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX5042A1?
The Trane 5TWX5042A1 is rated at up to 16.5 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 231 certified matchups SEER2 ranges from 15.2-16.5.
Is the Trane 5TWX5042A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Trane 5TWX5042A1 cost to run per year?
At its rated efficiency it costs about $1,138-$2,957 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,391 in Phoenix and $2,461 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX5042A1?
ENERGY STAR lists 231 certified combinations for this outdoor unit. The highest-rated ones use 5TXCD008AS3+TSTAT+P0V0D000M50SD, 5PX*D008AS3+TSTAT+P0V0D000M50SD, 5PX*D010AS3+TSTAT.
What refrigerant does the Trane 5TWX5042A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,374/yrYou save $681/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX5042A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,374
Current system, per year
$2,054
You save per year
$681
Payback
22.0 years
Net after 10 years
-$8,195

Cooling $853Heating $520Electricity used: 8,586 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 16, 2026. How we use the data.