3-ton central heat pump · T2 Series
VillaTherm VHP-UCHA-36HDCT-A
Very good cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #69 of 302 3 ton central heat pumps for cooling efficiency, and costs about $929 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonVery good · beats 77%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 11.3 Cooling efficiency on a 95°F dayBelow average · beats 29%
- Heat at 5°F
- 25,600 BTU/h73% of its 47°F outputVery good · beats 88%
A good fit if…
- You want low cooling bills - its SEER2 beats 77% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 25,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | VillaTherm |
| Outdoor unit model | VHP-UCHA-36HDCT-A |
| Series | T2 Series |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | January 10, 2026 |
| Last certified | September 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 18.0-18.5) |
| EER2Efficiency at 95°F outdoors | 11.0-11.3 |
| Cooling capacity | 34,200 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-10.0 |
| Capacity at 47°F | 34,200 BTU/h |
| Capacity at 17°F | 23,000-31,400 BTU/h |
| Capacity at 5°F | 25,000-25,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.20-2.30 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with VAH-UCHA-36HDC-A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| VAH-UCHA-36HDC-A · cold climate | 18.5 | 11.3 | 9.0 | 25,000 | 218046441 |
| VAH-UCHA-36HDC · cold climate | 18.5 | 11.3 | 9.0 | 25,000 | 218393472 |
| VAH-UCHA-36SHDCALN2 · cold climate | 18.5 | 11.3 | 9.0 | 25,000 | 218775069 |
| VAH-UCHA-36HDC · cold climate | 18.5 | 11.3 | 9.0 | 25,000 | 218775076 |
| VAH-UCHA-36SHDCALN2 · cold climate | 18.0 | 11.0 | 10.0 | 25,600 | 218696918 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,051/yr
- Miami, FL$867/yr
- Houston, TX$941/yr
- Atlanta, GA$929/yr
- Los Angeles, CA$899/yr
- New York, NY$2,191/yr
- Chicago, IL$1,774/yr
- Denver, CO$1,470/yr
- Seattle, WA$900/yr
- Minneapolis, MN$1,817/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the VillaTherm VHP-UCHA-36HDCT-A?
- The VillaTherm VHP-UCHA-36HDCT-A is rated at up to 18.5 SEER2 and 11.3 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 5 certified matchups SEER2 ranges from 18.0-18.5.
- Is the VillaTherm VHP-UCHA-36HDCT-A good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 25,600 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
- How much does the VillaTherm VHP-UCHA-36HDCT-A cost to run per year?
- At its rated efficiency it costs about $867-$2,191 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,051 in Phoenix and $1,817 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the VillaTherm VHP-UCHA-36HDCT-A?
- ENERGY STAR lists 5 certified combinations for this outdoor unit. The highest-rated ones use VAH-UCHA-36HDC-A, VAH-UCHA-36HDC, VAH-UCHA-36SHDCALN2.
- What refrigerant does the VillaTherm VHP-UCHA-36HDCT-A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- GREE FXU36HP230V1R45AO · cold climate18.5 SEER2 · 10.0 HSPF2
- ECOER EODA18H-2436BAA · cold climate18.5 SEER2 · 9.0 HSPF2
- COSTWAY FP10982US · cold climate18.6 SEER2 · 9.0 HSPF2
- UTL UCHA-36HDCT · cold climate18.5 SEER2 · 9.0 HSPF2
- Concord 7SCP18V36P-**A · cold climate18.7 SEER2 · 9.6 HSPF2
- UTL UCHA-36HDCTN2 · cold climate18.5 SEER2 · 9.0 HSPF2
- TOSOT TU36W-GDU19.0 SEER2 · 8.3 HSPF2
- Invertercool COH17S-36AD · cold climate18.5 SEER2 · 8.8 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.