HVAC Rated

2-ton central heat pump · LX SERIES

York YH624E2S11

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #302 of 331 2 ton central heat pumps for cooling efficiency, and costs about $773 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
12,800 BTU/h53% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 157 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandYork
Outdoor unit modelYH624E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 1, 2025
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity22,800-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F22,600-24,000 BTU/h
Capacity at 17°F14,500-15,500 BTU/h
Capacity at 5°F11,900-12,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM36B5ADS1 at the standard test temperatures, in BTU/h:

Certified matchups157 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 157 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTM36B5ADS1Y82E080B12LMPS116.012.08.112,400217019514
JHE30B5AD2SS1-16.012.08.112,100217019524
CTF36B5ADS1+JME08B2SN1-16.012.08.112,000217019530
CTU36B5XDS1+JME08B2SN1+TXV-16.012.08.112,000217019532
CTF36B5ADS1+JMC12B2SN1-16.012.08.112,300217019534
CTU36B5XDS1+JMC12B2SN1+TXV-16.012.08.112,300217019536
CTF36B5ADS1Y92E080B12SMPS116.012.08.112,400217019538
CTU36B5XDS1+TXVY92E080B12SMPS116.012.08.112,400217019540
JHC36B5AD2SS1-16.012.08.112,400217019544
CTF36B5ADS1+JME12B2SN1-16.012.08.112,300217019546
CTU36B5XDS1+JME12B2SN1+TXV-16.012.08.112,300217019548
CTM36B5ADS1Y81E100B12SMPS116.012.08.112,500217019567
CTM36B5ADS1Y81E100B12LMPS116.012.08.112,500217019569
CTF36B5ADS1Y81E100B12SMPS116.012.08.112,500217019571
CTF36B5ADS1Y81E100B12LMPS116.012.08.112,500217019573
CTU36B5XDS1+TXVY81E100B12SMPS116.012.08.112,500217019575
JHE36B5AD2SS1-16.012.08.112,300217019472
CTF36B5ADS1Y82E080B12LMPS116.012.08.112,400217019474
CTU36B5XDS1+TXVY82E080B12LMPS116.012.08.112,400217019476
CTF36B5ADS1Y91E080B12SMPS116.012.08.112,400217019480
CTU36B5XDS1+TXVY91E080B12SMPS116.012.08.112,400217019482
CTM36B5ADS1+JME12B2SN1-16.012.08.112,200217019488
CTF36B5ADS1Y81E080B12SMPS116.012.08.112,400217019496
CTF36B5ADS1Y81E080B12LMPS116.012.08.112,400217019498
CTU36B5XDS1+TXVY81E080B12SMPS116.012.08.112,400217019500
CTU36B5XDS1+TXVY81E080B12LMPS116.012.08.112,400217019502
CTF36B5ADS1+JMVT12BC2N1-16.012.08.112,300217019510
CTU36B5XDS1+JMVT12BC2N1+TXV-16.012.08.112,300217019512
CTU36B5XDS1+TXVY81E100B12LMPS116.012.08.112,500217019577
CTU36B5XDS1+TXVY82V080B12SMPC116.012.08.112,400217445093
CTF36B5ADS1Y82V080B12SMPC116.012.08.112,400217445092
JHE30B5AD2SS2-16.012.08.112,100218456720
CTM36B5ADS2Y81E100B12LMPS116.012.08.112,500218508189
CTM36B5ADS2Y81E100B12SMPS116.012.08.112,500218508186
CTM36B5ADS2Y82E080B12LMPS116.012.08.112,400218508184
CTU36B5XDS2+TXVY92E080B12SMPS116.012.08.112,400218508100
CTF36B5ADS2Y92E080B12SMPS116.012.08.112,400218508097
CTU36B5XDS2+TXVY81E100B12LMPS116.012.08.112,500218508094
CTU36B5XDS2+TXVY81E100B12SMPS116.012.08.112,500218508092
CTF36B5ADS2Y81E100B12LMPS116.012.08.112,500218508089
CTF36B5ADS2Y81E100B12SMPS116.012.08.112,500218508086
CTU36B5XDS2+TXVY81E080B12LMPS116.012.08.112,400218508079
CTU36B5XDS2+TXVY81E080B12SMPS116.012.08.112,400218508076
CTF36B5ADS2Y81E080B12LMPS116.012.08.112,400218508073
CTF36B5ADS2Y81E080B12SMPS116.012.08.112,400218508070
CTU36B5XDS2+TXVY91E080B12SMPS116.012.08.112,400218508067
CTF36B5ADS2Y91E080B12SMPS116.012.08.112,400218508064
CTU36B5XDS2+JMC12B2SN1+TXV-16.012.08.112,300218508061
CTF36B5ADS2+JMC12B2SN1-16.012.08.112,300218508058
CTU36B5XDS2+JMVT12BC2N1+TXV-16.012.08.112,300218508055
CTF36B5ADS2+JMVT12BC2N1-16.012.08.112,300218508053
CTU36B5XDS2+TXVY82E080B12LMPS116.012.08.112,400218508050
CTF36B5ADS2Y82E080B12LMPS116.012.08.112,400218508048
CTU36B5XDS2+TXVY82V080B12SMPC116.012.08.112,400218508040
CTF36B5ADS2Y82V080B12SMPC116.012.08.112,400218508037
JHE24B5AC2SS1-16.012.08.012,000217016555
CTF36B5ADS1+JMET12BS2N1-16.012.08.012,000217019559
CTU36B5XDS1+JMET12BS2N1+TXV-16.012.08.012,000217019561
CTM36B5ADS1+JME08B2SN1-16.012.08.012,000217019508
JHE24B5AC2SS2-16.012.08.012,000218456719
Yearly running cost in 10 large cities$704-$1,836

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH624E2S11?
The York YH624E2S11 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 157 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH624E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the York YH624E2S11 cost to run per year?
At its rated efficiency it costs about $704-$1,836 a year in electricity in large U.S. cities, depending on climate and local rates - for example $862 in Phoenix and $1,529 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH624E2S11?
ENERGY STAR lists 157 certified combinations for this outdoor unit. The highest-rated ones use CTM36B5ADS1, JHE30B5AD2SS1, CTF36B5ADS1+JME08B2SN1.
What refrigerant does the York YH624E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $852/yrYou save $376/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH624E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$852
Current system, per year
$1,228
You save per year
$376
Payback
23.9 years
Net after 10 years
-$5,239

Cooling $528Heating $324Electricity used: 5,322 kWhSaved vs. a minimum-efficiency heat pump: $89

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.