5-ton central heat pump · Crossover Heat Pump
Bryant 37MUHAQ60AA3+KSAIC0701230
Below average cooling efficiency and average heating efficiency for a 5-ton central heat pump, and certified for cold climates.
Ranks #44 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,723 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 9.8 Cooling efficiency on a 95°F dayBelow average · beats 6%
- Heat at 5°F
- 51,500 BTU/h91% of its 47°F outputBelow average · beats 2%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 51,500 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 11 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | Bryant |
| Also sold as | Carrier, PAYNE HEATING AND COOLING, WeatherMaker |
| Outdoor unit model | 37MUHAQ60AA3+KSAIC0701230 |
| Series | Crossover Heat Pump |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | June 27, 2024 |
| Last certified | October 7, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 9.0-9.8 |
| Cooling capacity | 55,500-56,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 56,000-56,500 BTU/h |
| Capacity at 17°F | 40,500-41,000 BTU/h |
| Capacity at 5°F | 51,000-51,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.76-1.78 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FT5ANBD60L at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FT5ANBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218475853 |
| PF5TNBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218477278 |
| FG5ANBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218477277 |
| FT5ANBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218477276 |
| FG5ANBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218477275 |
| PF5TNBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218495510 |
| PF5TNBD60L · cold climate | - | 16.0 | 9.8 | 9.0 | 51,000 | 218816491 |
| CAA**6124AM · cold climate | 58SU*B080M21**20 | 15.2 | 9.0 | 9.0 | 51,500 | 218475957 |
| CAA**6124AM · cold climate | 83*SB60080M21*** | 15.2 | 9.0 | 9.0 | 51,500 | 218478628 |
| CAA**6124AM · cold climate | PG80MSUA60080C** | 15.2 | 9.0 | 9.0 | 51,500 | 218495575 |
| CAA**6124AM · cold climate | PG80MSUA60080C** | 15.2 | 9.0 | 9.0 | 51,500 | 218816523 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,984/yr
- Miami, FL$1,653/yr
- Houston, TX$1,776/yr
- Atlanta, GA$1,723/yr
- Los Angeles, CA$1,660/yr
- New York, NY$4,028/yr
- Chicago, IL$3,252/yr
- Denver, CO$2,690/yr
- Seattle, WA$1,642/yr
- Minneapolis, MN$3,323/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Bryant 37MUHAQ60AA3+KSAIC0701230?
- The Bryant 37MUHAQ60AA3+KSAIC0701230 is rated at up to 16.0 SEER2 and 9.8 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 11 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Bryant 37MUHAQ60AA3+KSAIC0701230 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 51,500 BTU/h at 5°F with a COP of 1.78, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the Bryant 37MUHAQ60AA3+KSAIC0701230 cost to run per year?
- At its rated efficiency it costs about $1,642-$4,028 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,984 in Phoenix and $3,323 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Bryant 37MUHAQ60AA3+KSAIC0701230?
- ENERGY STAR lists 11 certified combinations for this outdoor unit. The highest-rated ones use FT5ANBD60L, PF5TNBD60L, FG5ANBD60L.
- What refrigerant does the Bryant 37MUHAQ60AA3+KSAIC0701230 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Arcoaire D5CUHAH60AAK+TIC2025-0016 · cold climate16.0 SEER2 · 9.0 HSPF2
- Carrier 37MUHAQ60AA3+TIC2025-0016 · cold climate16.0 SEER2 · 9.0 HSPF2
- ECOTEMP W4H7T60*K*AAA16.5 SEER2 · 8.1 HSPF2
- Tempstar D5CUHAH60AAK+KSAIC0701230 · cold climate16.0 SEER2 · 9.0 HSPF2
- AUX AHU60HPV1BO · cold climate16.5 SEER2 · 9.5 HSPF2
- Daikin DH5SEA6010A16.0 SEER2 · 8.2 HSPF2
- COSTWAY FP10983US · cold climate17.0 SEER2 · 8.6 HSPF2
- Coleman THF2B60T2116.0 SEER2 · 8.1 HSPF2
See all 100 5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.