HVAC Rated

5-ton central heat pump · LX SERIES

Coleman THF2B60T21

Below average cooling and heating efficiency for a 5-ton central heat pump, but not rated for cold climates.

Ranks #48 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,834 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
32,800 BTU/h53% of its 47°F output
Excellent · beats 97%

A good fit if…

  • You want a choice of indoor units - 937 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications5 ton, R-410A
General
BrandColeman
Also sold asLuxaire, Fraser-Johnston, Johnson Controls, CHAMPION HEATING AND COOLING
Outdoor unit modelTHF2B60T21
SeriesLX SERIES
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 18, 2023
Last certifiedAugust 12, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity53,000-57,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F54,500-59,500 BTU/h
Capacity at 17°F37,400-39,000 BTU/h
Capacity at 5°F29,200-32,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.46
ENERGY STAR cold climateNo
Heating output as it gets colder53% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHD60JBCN1 at the standard test temperatures, in BTU/h:

Certified matchups937 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 937 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAHD60JBCN1Z8ET100C20LMPS116.011.78.131,200212414984
XAHD60JBCN1Z8ET100C20LMPS116.011.78.131,200212414983
XAHD60JBCN1Z8ET100C20LMPS116.011.78.131,200212414986
XAHD60JBCN1Z8ET100C20LMPS116.011.78.131,200212414982
XAHD60JBCN1Z8ET100C20LMPS116.011.78.131,200212414985
XAFD60HXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210351867
XAFD60HXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210351868
XAFD60HXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210351865
XAFD60HXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210351866
XAFD60HXXN1+JMET18DS2N1+TXV-16.011.78.130,800210358460
XAFD60HXXN1+JMET18DS2N1+TXV-16.011.78.130,800210358462
XAFD60HXXN1+JMET18DS2N1+TXV-16.011.78.130,800210358463
XAFD60HXXN1+JMET18DS2N1+TXV-16.011.78.130,800210358461
XAFD60JXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210353430
XAFD60JXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210353431
XAFD60JXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210353432
XAFD60JXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210353429
XAFD60JXXN1+JMET18DS2N1+TXV-16.011.78.130,600210361845
XAFD60JXXN1+JMET18DS2N1+TXV-16.011.78.130,600210361844
XAFD60JXXN1+JMET18DS2N1+TXV-16.011.78.130,600210361846
XAFD60JXXN1+JMET18DS2N1+TXV-16.011.78.130,600210361847
XAFD60JXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210845565
XAFD60HXXN1+JMET18DS2N1+TXV-16.011.78.130,800210845296
XAFD60HXXN1+JMVT20DC2N1+TXV-16.011.78.130,800210851163
XAFD60JXXN1+JMET18DS2N1+TXV-16.011.78.130,600210850066
JHVTD60JBCC2N1-16.011.78.130,600210353437
JHVTD60JBCC2N1-16.011.78.130,600210353438
JHVTD60JBCC2N1-16.011.78.130,600210353439
JHVTD60JBCC2N1-16.011.78.130,600210353440
JHVTD60HBCC2N1-16.011.78.130,600210361168
JHVTD60HBCC2N1-16.011.78.130,600210361169
JHVTD60HBCC2N1-16.011.78.130,600210361170
JHVTD60HBCC2N1-16.011.78.130,600210361171
JHETD60HBCS2N1-16.011.78.130,600210361172
JHETD60HBCS2N1-16.011.78.130,600210361173
JHETD60HBCS2N1-16.011.78.130,600210361174
JHETD60HBCS2N1-16.011.78.130,600210361175
JHETD60JBCS2N1-16.011.78.130,800210361856
JHETD60JBCS2N1-16.011.78.130,800210361857
JHETD60JBCS2N1-16.011.78.130,800210361858
JHETD60JBCS2N1-16.011.78.130,800210361859
JHETD60HBCS2N1-16.011.78.130,600211755657
JHVTD60HBCC2N1-16.011.78.130,600211755658
JHETD60JBCS2N1-16.011.78.130,800211755660
JHVTD60JBCC2N1-16.011.78.130,600211755702
XAFD60HBCN1+JMVT20DC2N1-16.011.78.130,800210351872
XAFD60HBCN1+JMVT20DC2N1-16.011.78.130,800210351869
XAFD60HBCN1+JMVT20DC2N1-16.011.78.130,800210351871
XAFD60HBCN1+JMVT20DC2N1-16.011.78.130,800210351870
XAFD60HBCN1+JMET18DS2N1-16.011.78.130,800210358468
XAFD60HBCN1+JMET18DS2N1-16.011.78.130,800210358466
XAFD60HBCN1+JMET18DS2N1-16.011.78.130,800210358467
XAFD60HBCN1+JMET18DS2N1-16.011.78.130,800210358469
XAFD60JBCN1+JMVT20DC2N1-16.011.78.130,800210353433
XAFD60JBCN1+JMVT20DC2N1-16.011.78.130,800210353436
XAFD60JBCN1+JMVT20DC2N1-16.011.78.130,800210353434
XAFD60JBCN1+JMVT20DC2N1-16.011.78.130,800210353435
XAFD60JBCN1+JMET18DS2N1-16.011.78.130,600210361851
XAFD60JBCN1+JMET18DS2N1-16.011.78.130,600210361850
XAFD60JBCN1+JMET18DS2N1-16.011.78.130,600210361853
Yearly running cost in 10 large cities$1,603-$4,413

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Coleman THF2B60T21?
The Coleman THF2B60T21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 937 certified matchups SEER2 ranges from 15.2-16.0.
Is the Coleman THF2B60T21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
How much does the Coleman THF2B60T21 cost to run per year?
At its rated efficiency it costs about $1,603-$4,413 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,993 in Phoenix and $3,701 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Coleman THF2B60T21?
ENERGY STAR lists 937 certified combinations for this outdoor unit. The highest-rated ones use XAHD60JBCN1, XAFD60HXXN1+JMVT20DC2N1+TXV, XAFD60HXXN1+JMET18DS2N1+TXV.
What refrigerant does the Coleman THF2B60T21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,987/yrYou save $864/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Coleman THF2B60T21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,987
Current system, per year
$2,851
You save per year
$864
Payback
23.7 years
Net after 10 years
-$11,861

Cooling $1,199Heating $788Electricity used: 12,420 kWhSaved vs. a minimum-efficiency heat pump: $206

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 12, 2026. How we use the data.