5-ton central heat pump · LX SERIES
EVCON RHP15060B21
Below average cooling and heating efficiency for a 5-ton central heat pump, but not rated for cold climates.
Ranks #49 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,830 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 32,800 BTU/h55% of its 47°F outputExcellent · beats 97%
A good fit if…
- You want a choice of indoor units - 38 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | EVCON |
| Also sold as | Guardian |
| Outdoor unit model | RHP15060B21 |
| Series | LX SERIES |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | May 18, 2023 |
| Last certified | August 12, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.0-12.0 |
| Cooling capacity | 53,000-56,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 54,500-59,500 BTU/h |
| Capacity at 17°F | 37,400-38,500 BTU/h |
| Capacity at 5°F | 30,600-32,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.22-2.46 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with JHETD60JBCS2N1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| JHETD60JBCS2N1 | - | 16.0 | 11.7 | 8.1 | 30,800 | 212541120 |
| JHETD60JBCS2N1 | - | 16.0 | 11.7 | 8.1 | 30,800 | 212541123 |
| JHETD60HBCS2N1 | - | 16.0 | 11.7 | 8.1 | 30,600 | 212541147 |
| JHETD60HBCS2N1 | - | 16.0 | 11.7 | 8.1 | 30,600 | 212541145 |
| JHVTD60JBCC2N1 | - | 16.0 | 11.7 | 8.1 | 30,600 | 212582161 |
| JHVTD60JBCC2N1 | - | 16.0 | 11.7 | 8.1 | 30,600 | 212582168 |
| JHVTD60HBCC2N1 | - | 16.0 | 11.7 | 8.1 | 30,600 | 212582171 |
| JHVTD60HBCC2N1 | - | 16.0 | 11.7 | 8.1 | 30,600 | 212582178 |
| JHVTC60HBCC2N1 | - | 15.2 | 11.7 | 8.1 | 30,800 | 212582187 |
| JHVTC60HBCC2N1 | - | 15.2 | 11.7 | 8.1 | 30,800 | 212582179 |
| XAFC60HBCN1+JME16C2SN1 | - | 15.2 | 11.7 | 8.1 | 31,600 | 214799856 |
| XAFC60HBCN1+JME16C2SN1 | - | 15.2 | 11.7 | 8.1 | 31,600 | 214799857 |
| XAFD60HBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 31,800 | 214799863 |
| XAFD60HBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 31,800 | 214799864 |
| XAFD60JBCN1+JME18D2SN1 | - | 15.2 | 11.7 | 8.1 | 31,200 | 214799897 |
| XAFD60JBCN1+JME18D2SN1 | - | 15.2 | 11.7 | 8.1 | 31,200 | 214799898 |
| XAHD60JBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 30,800 | 214799909 |
| XAHD60JBCN1+JME18D2SN1 | - | 15.2 | 12.0 | 8.1 | 30,800 | 214799910 |
| XAHD60JBCN1 | RG19120D20MPS1 | 15.2 | 11.0 | 8.1 | 31,400 | 214647943 |
| XAHD60JBCN1 | RG19120D20MPS1 | 15.2 | 11.0 | 8.1 | 31,400 | 214647942 |
| XAFD60JBCN1 | RG19120D20MPS1 | 15.2 | 11.0 | 8.1 | 31,800 | 214647949 |
| XAFD60JBCN1 | RG19120D20MPS1 | 15.2 | 11.0 | 8.1 | 31,800 | 214647950 |
| XAHD60HBCN1 | RL18130D20MPS1 | 15.2 | 11.7 | 7.8 | 32,600 | 212478699 |
| XAHD60HBCN1 | RL18120C16MPS1 | 15.2 | 11.7 | 7.8 | 32,600 | 212478715 |
| XAHD60HBCN1 | RL18120C16MPS1 | 15.2 | 11.7 | 7.8 | 32,600 | 212478716 |
| XAFC60HBCN1 | RL18080C16MPS1 | 15.2 | 11.7 | 7.8 | 31,000 | 212480008 |
| XAFC60HBCN1 | RL18080C16MPS1 | 15.2 | 11.7 | 7.8 | 31,000 | 212480010 |
| XAFD60HBCN1 | RL18080C16MPS1 | 15.2 | 11.7 | 7.8 | 31,000 | 212489301 |
| XAFD60HBCN1 | RL18080C16MPS1 | 15.2 | 11.7 | 7.8 | 31,000 | 212489300 |
| XAHC60HBCN1 | RL18080C16MPS1 | 15.2 | 11.7 | 7.8 | 32,400 | 212476620 |
| XAHC60HBCN1 | RL18080C16MPS1 | 15.2 | 11.7 | 7.8 | 32,400 | 212476619 |
| XAHD60HBCN1 | RL18130D20MPS1 | 15.2 | 11.7 | 7.8 | 32,600 | 212478698 |
| XAHC60HBCN1 | RL18100C20MPS1 | 15.2 | 11.7 | 7.8 | 32,800 | 212486013 |
| XAHC60HBCN1 | RL18100C20MPS1 | 15.2 | 11.7 | 7.8 | 32,800 | 212486012 |
| JHETC60HBCS2N1 | - | 15.2 | 11.7 | 7.8 | 30,600 | 212541165 |
| JHETC60HBCS2N1 | - | 15.2 | 11.7 | 7.8 | 30,600 | 212541169 |
| XAFD60HBCN1 | RG19120D20MPS1 | 15.2 | 11.7 | 7.8 | 31,600 | 214647935 |
| XAFD60HBCN1 | RG19120D20MPS1 | 15.2 | 11.7 | 7.8 | 31,600 | 214647936 |
Yearly running cost in 10 large cities
- Phoenix, AZ$2,002/yr
- Miami, FL$1,616/yr
- Houston, TX$1,795/yr
- Atlanta, GA$1,830/yr
- Los Angeles, CA$1,783/yr
- New York, NY$4,389/yr
- Chicago, IL$3,567/yr
- Denver, CO$2,968/yr
- Seattle, WA$1,826/yr
- Minneapolis, MN$3,674/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the EVCON RHP15060B21?
- The EVCON RHP15060B21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 38 certified matchups SEER2 ranges from 15.2-16.0.
- Is the EVCON RHP15060B21 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
- How much does the EVCON RHP15060B21 cost to run per year?
- At its rated efficiency it costs about $1,616-$4,389 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,002 in Phoenix and $3,674 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the EVCON RHP15060B21?
- ENERGY STAR lists 38 certified combinations for this outdoor unit. The highest-rated ones use JHETD60JBCS2N1, JHETD60HBCS2N1, JHVTD60JBCC2N1.
- What refrigerant does the EVCON RHP15060B21 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Coleman THF2B60T2116.0 SEER2 · 8.1 HSPF2
- Friedrich FWP15AZ60AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Daikin DH5SEA6010A16.0 SEER2 · 8.2 HSPF2
- Fujitsu FOP1560TJAZNA · cold climate16.0 SEER2 · 8.1 HSPF2
- Tempstar D5CUHAH60AAK+KSAIC0701230 · cold climate16.0 SEER2 · 9.0 HSPF2
- LPS Legacy H4H7T60*K*AAA16.0 SEER2 · 8.1 HSPF2
- Carrier 37MUHAQ60AA3+TIC2025-0016 · cold climate16.0 SEER2 · 9.0 HSPF2
- Mainline MPP15AZ60AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
See all 100 5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 12, 2026. How we use the data.