HVAC Rated

1.5-ton central heat pump · PRESTIGE SERIES

Friedrich RD18AY24AJVC

Very good cooling and heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.

Ranks #31 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $565 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,400 BTU/h85% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,400 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandFriedrich
Also sold asRheem, Ruud, Sure, RUSSELL
Outdoor unit modelRD18AY24AJVC
SeriesPRESTIGE SERIES
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceDecember 14, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 17.0-19.0)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity20,800-21,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-10.0
Capacity at 47°F20,600-24,000 BTU/h
Capacity at 17°F17,900-19,800 BTU/h
Capacity at 5°F16,800-18,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder85% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RCFY2417STANM at the standard test temperatures, in BTU/h:

Certified matchups399 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 399 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
RCFY2417STANM · cold climateR801V0754A17UH19.011.710.018,100217176000
RCFY2417STANM · cold climateR801V0503A14DZ19.011.710.018,100217176001
RCFY2417STANM · cold climateFR801V0754A17UH19.011.710.018,100217176014
RCFY2417STANM · cold climateR801V0754A17UH19.011.710.018,100217176016
RCFY2417STANM · cold climateR801V0503A14DZ19.011.710.018,100217176017
RCFY2417STANM · cold climateR802V0503A14DZ19.011.710.018,200217176020
RCFY2417STANM · cold climateR802V0503A14DZ19.011.710.018,200217176023
RCFY2417STANM · cold climateFR802V0503A14DZ19.011.710.018,200217176024
RCFY2417STANM · cold climateR802V0754A17UH19.011.710.018,100217176025
RCFY2417STANM · cold climateFR801V0503A14DZ19.011.710.018,100217176028
RCFY2417STANM · cold climateR802V0754A17UH19.011.710.018,100217176030
RCFY2417STANM · cold climateFR802V0754A17UH19.011.710.018,100217176035
SH2VY2417STACN · cold climate-19.012.010.018,000217176036
SH2VY2417STACN · cold climate-19.012.010.018,000217176037
RH2VY2417STACN · cold climate-19.012.010.018,000217176038
SH2VY2417STACN · cold climate-19.012.010.018,000217176039
RH2VY2417STACN · cold climate-19.012.010.018,000217176040
RHMVY2417SEACN · cold climate-19.012.010.018,000217176082
RHMVY2417SEACN · cold climate-19.012.010.018,000217176083
RHMVY2417SEACN · cold climate-19.012.010.018,000217176084
SHMVY2417SEACN · cold climate-19.012.010.018,000217176086
SHMVY2417SEACN · cold climate-19.012.010.018,000217176085
RCFY2417STANM · cold climateR802V0503A14UH19.011.010.018,200217176007
RCFY2417STANM · cold climateR801V0503A14UH19.011.010.018,200217176010
RCFY2417STANM · cold climateR802V0503A14UH19.011.010.018,200217176013
RCFY2417STANM · cold climateR801V0503A14UH19.011.010.018,200217176018
RCFY2417STANM · cold climateFR802V0503A14UH19.011.010.018,200217176022
RCFY2417STANM · cold climateFR801V0503A14UH19.011.010.018,200217176032
RCFY2417STANM · cold climateU98MV0603A17UPS19.011.010.018,200217176044
RCFY2417STANM · cold climateR97MV0603A17DH19.011.010.018,200217176045
RCFY2417STANM · cold climateFR97MV0703A17DH19.011.010.018,200217176046
RCFY2417STANM · cold climateR98MV0603A17UP19.011.010.018,200217176048
RCFY2417STANM · cold climateFR98MV0603A17UP19.011.010.018,200217176047
RCFY2417STANM · cold climateR98MV0703A17UP19.011.010.018,200217176049
RCFY2417STANM · cold climateR97MV0703A17DH19.011.010.018,200217176051
RCFY2417STANM · cold climateU97MV0603A17DHS19.011.010.018,200217176055
RCFY2417STANM · cold climateFR98MV0703A17UP19.011.010.018,200217176064
RCFY2417STANM · cold climateU97MV0703A17DHS19.011.010.018,200217176068
RCFY2417STANM · cold climateFR97MV0603A17DH19.011.010.018,200217176071
RCFY2417STANM · cold climateU98MV0703A17UPS19.011.010.018,200217176078
TCFY2417STANM · cold climateFR801V0754A17UH19.011.710.018,100217562052
TCFY2417STANM · cold climateFR802V0503A14UH19.011.010.018,200217562054
TCFY2417STANM · cold climateFR802V0503A14DZ19.011.710.018,200217562055
TCFY2417STANM · cold climateFR801V0503A14DZ19.011.710.018,100217562057
TCFY2417STANM · cold climateFR801V0503A14UH19.011.010.018,200217562059
TCFY2417STANM · cold climateFR802V0754A17UH19.011.710.018,100217562060
TCFY2417STANM · cold climateFR97MV0703A17DH19.011.010.018,200217562061
TCFY2417STANM · cold climateFR98MV0603A17UP19.011.010.018,200217562062
TCFY2417STANM · cold climateFR98MV0703A17UP19.011.010.018,200217562066
TCFY2417STANM · cold climateFR97MV0603A17DH19.011.010.018,200217562070
RHMVY2421MEACN · cold climate-19.012.08.516,800216980443
RHMVY2421MEACN · cold climate-19.012.08.516,800216980444
SHMVY2421MEACN · cold climate-19.012.08.516,800217165996
SHMVY2421MEACN · cold climate-19.012.08.516,800217165999
FRHMVY2421MEACN · cold climate-19.012.08.516,800217166002
RCFY2417STANM · cold climateFR801V1004A17UH18.011.710.018,100217176027
RCFY2417STANM · cold climateR801V1004A17UH18.011.710.018,100217176029
RCFY2417STANM · cold climateR801V1004A17UH18.011.710.018,100217176034
RH2TY2417STANN · cold climate-18.012.010.018,000217176041
RH2TY2417STANN · cold climate-18.012.010.018,000217176042
Yearly running cost in 10 large cities$519-$1,338

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich RD18AY24AJVC?
The Friedrich RD18AY24AJVC is rated at up to 19.0 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 399 certified matchups SEER2 ranges from 17.0-19.0.
Is the Friedrich RD18AY24AJVC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Friedrich RD18AY24AJVC cost to run per year?
At its rated efficiency it costs about $519-$1,338 a year in electricity in large U.S. cities, depending on climate and local rates - for example $633 in Phoenix and $1,113 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich RD18AY24AJVC?
ENERGY STAR lists 399 certified combinations for this outdoor unit. The highest-rated ones use RCFY2417STANM, SH2VY2417STACN, RH2VY2417STACN.
What refrigerant does the Friedrich RD18AY24AJVC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $624/yrYou save $459/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich RD18AY24AJVC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$624
Current system, per year
$1,083
You save per year
$459
Payback
17.4 years
Net after 10 years
-$3,414

Cooling $389Heating $235Electricity used: 3,902 kWhSaved vs. a minimum-efficiency heat pump: $206

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.