HVAC Rated

3-ton central heat pump · 15 Single-Stage Heat Pump

Trane 5TWR5036A1

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #198 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,014 a year to run in a mixed climate like Atlanta.

SEER2
16.5 Cooling efficiency over a season
Average · beats 40%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
17,800 BTU/h55% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want a choice of indoor units - 481 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model5TWR5036A1
Series15 Single-Stage Heat Pump
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 25, 2024
Last certifiedJune 3, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.5 (range 15.2-16.5)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity31,800-35,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F29,800-32,800 BTU/h
Capacity at 17°F20,800-22,400 BTU/h
Capacity at 5°F16,600-17,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.40
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TEMCD06AV41+TDR+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups481 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 481 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TEMCD06AV41+TDR+TSTAT-16.512.08.517,100215863938
5PX*CD09AS3+TSTAT+P0V0C000M50SD-16.512.08.117,300215568628
5PX*CD09AS3+TSTATS9V2C100D5PSC16.512.08.117,500215568636
5PX*CD09AS3+TSTATS9V2C100D4VSB16.512.08.117,500215568638
5PX*D010AS3+TSTATS8V2D120M5PDB16.512.08.117,300215568686
5PX*D010AS3+TSTATS8V2D120M5PCB16.512.08.117,300215568692
5PX*C007AS3+TSTAT+P0V0C000M50SD-16.512.08.117,300215568450
5TEMCD07AV51+TDR+TSTAT-16.512.08.117,100215863940
5TEM6D04AV31+TDR+TSTAT-16.012.08.517,500214078521
5TEM6D06AV41+TDR+TSTAT-16.012.08.517,400214078523
5TEM6D07AV51+TDR+TSTAT-16.012.08.517,500214078525
5PX*D008AS3+TSTATS9V2D120U5VSB16.012.08.517,600215568652
5PX*D008AS3+TSTATS9V2D120U5PSC16.012.08.517,600215568654
5PX*D008AS3+TSTATS8X2D120M5PTC16.012.08.517,400215568656
5PX*D008AS3+TSTATS8X2D120M5PSC16.012.08.517,400215568658
5PX*D008AS3+TSTATS8V2D120M5PDB16.012.08.517,600215568660
5PX*D008AS3+TSTATS8X1D120M5PSC16.012.08.517,400215568662
5PX*D008AS3+TSTATS8V2D120M5PCB16.012.08.517,600215568670
5PX*D008AS3+TSTATS8X1D120M5PTC16.012.08.517,400215568672
5PX*D010AS3+TSTAT*UHMD120CCV516.012.08.517,600215568696
5TXCD008AS3+TSTATS8X2D120M5PTC16.012.08.517,400215566428
5TXCD008AS3+TSTATS8X2D120M5PSC16.012.08.517,400215566430
5TXCD008AS3+TSTATS8X1D120M5PTC16.012.08.517,400215566432
5TXCD008AS3+TSTATS9V2D120U5PSC16.012.08.517,600215566434
5TXCD008AS3+TSTATS8V2D120M5PDB16.012.08.517,600215566436
5TXCD008AS3+TSTATS8V2D120M5PCB16.012.08.517,600215566442
5TXCD008AS3+TSTATS8X1D120M5PSC16.012.08.517,400215566444
5PX*C007AS3+TSTATS9V2C100U4VSB16.012.08.517,600215568478
5PX*C007AS3+TSTATS9V2C100U5PSC16.012.08.517,700215568480
5TEM6D05AV41+TDR+TSTAT-16.012.08.517,500215610943
5TEMCD04AV31+TDR+TSTAT-16.012.08.517,200215863934
5TEMCD05AV41+TDR+TSTAT-16.012.08.517,200215863936
5PX*C007AS3+TSTATS9V2C100U5VSB16.012.08.517,600215831464
5PX*C007AS3+TSTATS9V2C080U5VSB16.012.08.517,700215831466
5TXCC007AS3+TSTATS9V2C080U5VSB16.012.08.517,700215831488
5TXCC007AS3+TSTATS9V2C100U5VSB16.012.08.517,600215831490
5TXCD008AS3+TSTATS9V2D120U5VSB16.012.08.517,600218363742
5TXCC007AS3+TSTATS9V2C100U5PSC16.012.08.117,100214078713
5TXCC007AS3+TSTATS8V2C080M5PCB16.012.08.117,200214078717
5TXCC007AS3+TSTAT+P0V0C000M50SD-16.012.08.117,000214078721
5TXCC007AS3+TSTAT+P0V0C000M50SC-16.012.08.117,000214078723
5TXCC007AS3+TSTATL8V1C100U5VSB16.012.08.117,100214078727
5TXCC007AS3+TSTAT*UHMC100CCV416.012.08.117,100214078729
5TXCC007AS3+TSTAT*UHMC100ACV416.012.08.117,000214078731
5TXCB006AS3+TSTAT*UHMB080CCV316.012.08.117,300214078629
5TXCB006AS3+TSTAT+P0V0B000M40SD-16.012.08.117,100214078653
5TXCC007AS3+TSTATS9V2C100U4VSB16.012.08.117,600214078769
5TXCC007AS3+TSTATS9V2C100U4VSA16.012.08.117,100214078767
5TXCC007AS3+TSTATS9V2C100U5PSB16.012.08.117,100214078771
5TXCC007AS3+TSTATS8V2C080M5PDB16.012.08.117,200214078773
5TXCD010AS3+TSTATS9V2D120U5VSB16.012.08.116,900214078777
5TXCD010AS3+TSTATS9V2D120U5VSA16.012.08.117,300214078779
5TXCD010AS3+TSTATS9V2D120U5PSC16.012.08.116,900214078781
5TXCD010AS3+TSTATS9V2D120U5PSB16.012.08.116,900214078783
5TXCD010AS3+TSTATS8X2D120M5PTC16.012.08.117,200214078785
5TXCD010AS3+TSTATS8V2D120M5PDA16.012.08.116,900214078787
5TXCD010AS3+TSTATS8V2D120M5PCB16.012.08.116,900214078789
5TXCD010AS3+TSTATS8V2D120M5PCA16.012.08.116,900214078791
5TXCD010AS3+TSTAT*UHMD120CCV516.012.08.117,000214078793
5TXCD010AS3+TSTAT*UHMD120ACV516.012.08.117,000214078795
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 5TWR5036A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$960-$2,380

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 5TWR5036A1?
The Trane 5TWR5036A1 is rated at up to 16.5 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 481 certified matchups SEER2 ranges from 15.2-16.5.
Is the Trane 5TWR5036A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Trane 5TWR5036A1 cost to run per year?
At its rated efficiency it costs about $960-$2,380 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,157 in Phoenix and $1,968 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 5TWR5036A1 the same as the American Standard 5A6H5036A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 5TWR5036A1?
ENERGY STAR lists 481 certified combinations for this outdoor unit. The highest-rated ones use 5TEMCD06AV41+TDR+TSTAT, 5PX*CD09AS3+TSTAT+P0V0C000M50SD, 5PX*CD09AS3+TSTAT.
What refrigerant does the Trane 5TWR5036A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,135/yrYou save $569/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWR5036A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,135
Current system, per year
$1,704
You save per year
$569
Payback
22.0 years
Net after 10 years
-$6,813

Cooling $721Heating $414Electricity used: 7,093 kWhSaved vs. a minimum-efficiency heat pump: $166

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.