HVAC Rated

3.5-ton central heat pump · 16 Single-Stage Heat Pump with WeatherGuard Top

Trane 5TWX6042A1

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #84 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,298 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
19,800 BTU/h48% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want a choice of indoor units - 188 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandTrane
Outdoor unit model5TWX6042A1
Series16 Single-Stage Heat Pump with WeatherGuard Top
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 16, 2026
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity38,500-41,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F38,500-40,500 BTU/h
Capacity at 17°F25,000-26,000 BTU/h
Capacity at 5°F18,700-19,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.11-2.30
ENERGY STAR cold climateNo
Heating output as it gets colder48% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 5TXCC009AS3+TSTAT at the standard test temperatures, in BTU/h:

Certified matchups188 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 188 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
5TXCC009AS3+TSTATL8V1C100U5VSB16.012.08.119,000218110810
5TXCC009AS3+TSTAT*UHMC100CCV416.012.08.119,100218110809
5TXCC009AS3+TSTAT+P0V0C000M50SD-16.012.08.119,000218110808
5TXCC009AS3+TSTATS8X2C080M5PSC16.012.08.119,200218110806
5TXCC009AS3+TSTATS9V2C080U5VSB16.012.08.119,100218110805
5TXCC009AS3+TSTATS9V2C100U4VSB16.012.08.119,000218110804
5TXCC009AS3+TSTATS9V2C100U5VSB16.012.08.119,000218110803
5TXCC009AS3+TSTATS9X1C080U5PSB16.012.08.119,100218110802
5TXCC009AS3+TSTATS9X2C080U5PSB16.012.08.119,100218110800
5TXCC009AS3+TSTATS8V2C100M5PCB16.012.08.119,200218110799
5TXCC009AS3+TSTATS8V2C100M5PDB16.012.08.119,200218110798
5TXCC009AS3+TSTATS8X1C080M5PSC16.012.08.119,200218110797
5TXCC009AS3+TSTATS8X1C080M5PTC16.012.08.119,200218110796
5TXCC009AS3+TSTATS8X1C100M5PSC16.012.08.119,300218110795
5TXCC009AS3+TSTATS8X1C100M5PTC16.012.08.119,300218110794
5TEMCD07AV51+TDR+TSTAT-16.012.08.118,700218110743
5TEMCD06AV41+TDR+TSTAT-16.012.08.118,900218110742
5TEM6D07AV51+TDR+TSTAT-16.012.08.118,800218110741
5TEM6D06AV41+TDR+TSTAT-16.012.08.118,800218110740
5TAM5D07AC51+TSTAT-16.012.08.119,200218110731
5TAM5D06AC41+TSTAT-16.012.08.119,000218110730
5PX*DD10AS3+TSTAT+P0V0D000M50SD-16.012.08.118,900218110726
5PX*D010AS3+TSTATS8X2D120M5PSC16.012.08.119,100218110722
5PX*D010AS3+TSTATS9X2D120U5PSB16.012.08.119,200218110721
5PX*D010AS3+TSTAT*UHMD120CCV516.012.08.119,000218110720
5PX*D010AS3+TSTATS8X1D120M5PSC16.012.08.119,100218110719
5PX*D010AS3+TSTATS8V2D120M5PDB16.012.08.119,100218110718
5PX*D010AS3+TSTAT+P0V0D000M50SD-16.012.08.118,900218110717
5PX*D010AS3+TSTATS9V2D120U5VSB16.012.08.119,100218110716
5PX*D010AS3+TSTATS8X2D120M5PTC16.012.08.119,100218110715
5PX*D010AS3+TSTATS9X1D120U5PSB16.012.08.119,200218110714
5PX*D008AS3+TSTATS8X1D120M5PTC16.012.08.119,200218110709
5PX*D008AS3+TSTATS8X2D120M5PSC16.012.08.119,200218110708
5PX*D008AS3+TSTATS8X2D120M5PTC16.012.08.119,200218110707
5PX*D008AS3+TSTATS8X1D120M5PSC16.012.08.119,200218110706
5PX*D008AS3+TSTATS9X2D120U5PSB16.012.08.119,300218110705
5PX*D008AS3+TSTATS8V2D120M5PCB16.012.08.119,300218110704
5PX*D008AS3+TSTATS8V2D120M5PDB16.012.08.119,300218110703
5PX*D008AS3+TSTATS9X1D120U5PSB16.012.08.119,300218110702
5PX*C009AS3+TSTATS8X2C080M5PSC16.012.08.119,200218110673
5PX*C009AS3+TSTATS8X1C080M5PTC16.012.08.119,200218110672
5PX*C009AS3+TSTATS8X1C100M5PSC16.012.08.119,300218110671
5PX*C009AS3+TSTATS8X1C100M5PTC16.012.08.119,300218110670
5PX*C009AS3+TSTATS8X2C080M5PTC16.012.08.119,200218110668
5PX*C009AS3+TSTATS8X2C100M5PSC16.012.08.119,300218110667
5PX*C009AS3+TSTATS8X2C100M5PTC16.012.08.119,300218110666
5PX*C009AS3+TSTATS9V2C080U5VSB16.012.08.119,100218110665
5PX*C009AS3+TSTATL8V1C100U5VSB16.012.08.119,000218110664
5PX*C009AS3+TSTAT+P0V0C000M50SD-16.012.08.119,000218110663
5PX*C009AS3+TSTATS8V2C100M5PCB16.012.08.119,200218110662
5PX*C009AS3+TSTATS8V2C100M5PDB16.012.08.119,200218110661
5PX*C009AS3+TSTATS8X1C080M5PSC16.012.08.119,200218110660
5PX*C009AS3+TSTATS9X1C080U5PSB16.012.08.119,100218110659
5PX*C009AS3+TSTATS9X2C080U5PSB16.012.08.119,100218110657
5PX*C007AS3+TSTATS8X2C100M5PSC16.012.08.119,400218110656
5PX*C007AS3+TSTATS8X1C100M5PTC16.012.08.119,400218110655
5PX*C007AS3+TSTATS8X1C100M5PSC16.012.08.119,400218110646
5TXCD010AS3+TSTATS8X1D120M5PSC16.012.08.119,100218110825
5TXCD010AS3+TSTATS8X1D120M5PTC16.012.08.119,100218110824
5TXCD010AS3+TSTATS8X2D120M5PSC16.012.08.119,100218110823
Yearly running cost in 10 large cities$1,174-$3,092

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Trane 5TWX6042A1?
The Trane 5TWX6042A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 188 certified matchups SEER2 ranges from 15.2-16.0.
Is the Trane 5TWX6042A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Trane 5TWX6042A1 cost to run per year?
At its rated efficiency it costs about $1,174-$3,092 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,441 in Phoenix and $2,578 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Trane 5TWX6042A1?
ENERGY STAR lists 188 certified combinations for this outdoor unit. The highest-rated ones use 5TXCC009AS3+TSTAT, 5TXCC009AS3+TSTAT+P0V0C000M50SD, 5TEMCD07AV51+TDR+TSTAT.
What refrigerant does the Trane 5TWX6042A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,426/yrYou save $628/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 5TWX6042A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,426
Current system, per year
$2,054
You save per year
$628
Payback
23.9 years
Net after 10 years
-$8,719

Cooling $880Heating $546Electricity used: 8,914 kWhSaved vs. a minimum-efficiency heat pump: $148

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.