2.5-ton central heat pump · Advantage 15 Heat Pump
Trane N5HP5030A1
Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.
Ranks #149 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $853 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 13,700 BTU/h53% of its 47°F outputVery good · beats 83%
A good fit if…
- You want a choice of indoor units - 86 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Trane |
| Also sold as | American Standard |
| Outdoor unit model | N5HP5030A1 |
| Series | Advantage 15 Heat Pump |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | May 26, 2026 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 27,400-29,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 24,200-25,800 BTU/h |
| Capacity at 17°F | 17,100-17,600 BTU/h |
| Capacity at 5°F | 13,300-13,700 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.13-2.26 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with A5AHV006A1D3+TDR+TSTAT at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 86 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| A5AHV006A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 13,300 | 218469561 |
| A5AHV005A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 13,400 | 218469560 |
| 5TXCC009AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218469549 |
| 5TXCC007AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218469546 |
| 5PX*D010AS3+TSTAT | A951X120DU5SA | 16.0 | 12.0 | 8.1 | 13,300 | 218469509 |
| 5PX*C009AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218469501 |
| 5PX*C007AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218469498 |
| 5PX*BD06AS3+TSTAT | A952V040BD3SB | 16.0 | 12.0 | 8.1 | 13,500 | 218469491 |
| 5PX*BD06AS3+TSTAT | A951X060BD3SA | 16.0 | 12.0 | 8.1 | 13,500 | 218469490 |
| 5PX*BD06AS3+TSTAT | A801X080BM4SD | 16.0 | 12.0 | 8.1 | 13,300 | 218469489 |
| 5PX*BD06AS3+TSTAT | A801X060BM4SD | 16.0 | 12.0 | 8.1 | 13,400 | 218469488 |
| 5PX*BD06AS3+TSTAT+P0V0B000M40SD | - | 16.0 | 12.0 | 8.1 | 13,300 | 218469487 |
| A5AHV006A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 13,300 | 218470272 |
| A5AHV005A1D3+TDR+TSTAT | - | 16.0 | 12.0 | 8.1 | 13,400 | 218470271 |
| 5TXCC009AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218470260 |
| 5TXCC007AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218470257 |
| 5PX*D010AS3+TSTAT | A951X120DU5SA | 16.0 | 12.0 | 8.1 | 13,300 | 218470221 |
| 5PX*C009AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218470215 |
| 5PX*C007AS3+TSTAT | A951X080CU5SA | 16.0 | 12.0 | 8.1 | 13,600 | 218470212 |
| 5PX*BD06AS3+TSTAT | A952V040BD3SB | 16.0 | 12.0 | 8.1 | 13,500 | 218470205 |
| 5PX*BD06AS3+TSTAT | A951X060BD3SA | 16.0 | 12.0 | 8.1 | 13,500 | 218470204 |
| 5PX*BD06AS3+TSTAT | A801X080BM4SD | 16.0 | 12.0 | 8.1 | 13,300 | 218470203 |
| 5PX*BD06AS3+TSTAT | A801X060BM4SD | 16.0 | 12.0 | 8.1 | 13,400 | 218470202 |
| 5PX*BD06AS3+TSTAT+P0V0B000M40SD | - | 16.0 | 12.0 | 8.1 | 13,300 | 218470201 |
| 5PX*BD06AS3+TSTAT | A952V060BD3SB | 16.0 | 12.0 | 8.0 | 13,300 | 218469483 |
| 5PX*BD06AS3+TSTAT | A952V060BD3SB | 16.0 | 12.0 | 8.0 | 13,300 | 218470197 |
| 5TXCC009AS3+TSTAT | A801X080CM5SD | 15.5 | 12.0 | 8.1 | 13,500 | 218469550 |
| 5TXCC007AS3+TSTAT | A951X100CU5SA | 15.5 | 12.0 | 8.1 | 13,500 | 218469547 |
| 5TXCB006AS3+TSTAT | A951X080BU4SA | 15.5 | 12.0 | 8.1 | 13,600 | 218469529 |
| 5TXCB006AS3+TSTAT | A952V040BU3SB | 15.5 | 12.0 | 8.1 | 13,400 | 218469528 |
| 5TXCB006AS3+TSTAT+P0V0B000M40SD | - | 15.5 | 12.0 | 8.1 | 13,500 | 218469527 |
| 5PX*C009AS3+TSTAT | A801X080CM5SD | 15.5 | 12.0 | 8.1 | 13,500 | 218469500 |
| 5PX*C007AS3+TSTAT | A951X100CU5SA | 15.5 | 12.0 | 8.1 | 13,500 | 218469495 |
| 5PX*BD06AS3+TSTAT | A951X080BD4SA | 15.5 | 12.0 | 8.1 | 13,600 | 218469493 |
| 5PX*BD06AS3+TSTAT | A952V080BD4SB | 15.5 | 12.0 | 8.1 | 13,600 | 218469492 |
| 5PX*BD06AS3+TSTAT+P0V0A000M30SD | - | 15.5 | 12.0 | 8.1 | 13,500 | 218469485 |
| 5PX*B006AS3+TSTAT | A951X080BU4SA | 15.5 | 12.0 | 8.1 | 13,600 | 218469460 |
| 5PX*B006AS3+TSTAT | A952V040BU3SB | 15.5 | 12.0 | 8.1 | 13,400 | 218469459 |
| 5PX*B006AS3+TSTAT+P0V0B000M40SD | - | 15.5 | 12.0 | 8.1 | 13,500 | 218469458 |
| 5TXCB006AS3+TSTAT+P0V0B000M40SD | - | 15.5 | 12.0 | 8.1 | 13,500 | 218470729 |
| 5TXCC009AS3+TSTAT | A801X080CM5SD | 15.5 | 12.0 | 8.1 | 13,500 | 218470261 |
| 5TXCC007AS3+TSTAT | A951X100CU5SA | 15.5 | 12.0 | 8.1 | 13,500 | 218470258 |
| 5TXCB006AS3+TSTAT | A951X080BU4SA | 15.5 | 12.0 | 8.1 | 13,600 | 218470240 |
| 5TXCB006AS3+TSTAT | A952V040BU3SB | 15.5 | 12.0 | 8.1 | 13,400 | 218470239 |
| 5PX*C009AS3+TSTAT | A801X080CM5SD | 15.5 | 12.0 | 8.1 | 13,500 | 218470214 |
| 5PX*C007AS3+TSTAT | A951X100CU5SA | 15.5 | 12.0 | 8.1 | 13,500 | 218470209 |
| 5PX*BD06AS3+TSTAT | A951X080BD4SA | 15.5 | 12.0 | 8.1 | 13,600 | 218470207 |
| 5PX*BD06AS3+TSTAT | A952V080BD4SB | 15.5 | 12.0 | 8.1 | 13,600 | 218470206 |
| 5PX*BD06AS3+TSTAT+P0V0A000M30SD | - | 15.5 | 12.0 | 8.1 | 13,500 | 218470199 |
| 5PX*B006AS3+TSTAT | A951X080BU4SA | 15.5 | 12.0 | 8.1 | 13,600 | 218470174 |
| 5PX*B006AS3+TSTAT | A952V040BU3SB | 15.5 | 12.0 | 8.1 | 13,400 | 218470173 |
| 5PX*B006AS3+TSTAT+P0V0B000M40SD | - | 15.5 | 12.0 | 8.1 | 13,500 | 218470172 |
| 5TXCB006AS3+TSTAT | A952V060BU4SB | 15.5 | 12.0 | 8.0 | 13,500 | 218469535 |
| 5TXCB006AS3+TSTAT | A801X080BM4SD | 15.5 | 12.0 | 8.0 | 13,500 | 218469534 |
| 5TXCB006AS3+TSTAT | A801X060BM4SD | 15.5 | 12.0 | 8.0 | 13,500 | 218469533 |
| 5TXCB006AS3+TSTAT | A952V080BU4SB | 15.5 | 12.0 | 8.0 | 13,500 | 218469532 |
| 5PX*BD06AS3+TSTAT | A801X060AM3SD | 15.5 | 12.0 | 8.0 | 13,700 | 218469484 |
| 5PX*B006AS3+TSTAT | A801X080BM4SD | 15.5 | 12.0 | 8.0 | 13,500 | 218469467 |
| 5PX*B006AS3+TSTAT | A952V080BU4SB | 15.5 | 12.0 | 8.0 | 13,500 | 218469462 |
| 5PX*B006AS3+TSTAT | A952V060BU4SB | 15.5 | 12.0 | 8.0 | 13,500 | 218469461 |
Yearly running cost in 10 large cities
- Phoenix, AZ$987/yr
- Miami, FL$825/yr
- Houston, TX$883/yr
- Atlanta, GA$853/yr
- Los Angeles, CA$821/yr
- New York, NY$1,988/yr
- Chicago, IL$1,604/yr
- Denver, CO$1,326/yr
- Seattle, WA$809/yr
- Minneapolis, MN$1,638/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Trane N5HP5030A1?
- The Trane N5HP5030A1 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 86 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Trane N5HP5030A1 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
- How much does the Trane N5HP5030A1 cost to run per year?
- At its rated efficiency it costs about $809-$1,988 a year in electricity in large U.S. cities, depending on climate and local rates - for example $987 in Phoenix and $1,638 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Trane N5HP5030A1?
- ENERGY STAR lists 86 certified combinations for this outdoor unit. The highest-rated ones use A5AHV006A1D3+TDR+TSTAT, A5AHV005A1D3+TDR+TSTAT, 5TXCC009AS3+TSTAT.
- What refrigerant does the Trane N5HP5030A1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- WeatherKing WP15AZ30AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- York YH2F30TB2116.0 SEER2 · 8.1 HSPF2
- Bryant 246SAN031**AA16.0 SEER2 · 8.0 HSPF2
- Bryant GH5SAN531**AA16.0 SEER2 · 8.0 HSPF2
- Bryant PH5SAN531**AA16.0 SEER2 · 8.0 HSPF2
- Thermal Zone TZPLAD1530AJN · cold climate16.0 SEER2 · 8.1 HSPF2
- Carrier 27SPA631A**3016.0 SEER2 · 8.0 HSPF2
- TCL THH36HES2NAGOH24 · cold climate16.0 SEER2 · 8.1 HSPF2
See all 199 2.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.