Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #238 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,052 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,400 BTU/h58% of its 47°F output
Excellent · beats 97%

A good fit if…

  • You want a choice of indoor units - 304 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandYork
Outdoor unit modelYH536E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 7, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity32,400-35,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F30,600-32,800 BTU/h
Capacity at 17°F20,400-22,000 BTU/h
Capacity at 5°F17,000-18,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.44
ENERGY STAR cold climateNo
Heating output as it gets colder58% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM48C5CFS1 at the standard test temperatures, in BTU/h:

Certified matchups304 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 304 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTM48C5CFS1Y82V080C16SMPC116.011.78.118,000217444676
CTM48C5CFS1Y82V100C16SMPC116.011.78.117,900217444677
CTF48C5CFS1Y82V080C16SMPC116.011.08.118,000217444678
CTU48C5XFS1+TXVY82V080C16SMPC116.011.08.118,000217444679
CTU48C5XFS1+TXVY82V100C16SMPC116.011.08.118,100217444681
CTF48C5CFS1Y82V100C16SMPC116.011.08.118,100217444680
CTU48C5XFS2+TXVY82V100C16SMPC116.011.08.118,100218501790
CTF48C5CFS2Y82V100C16SMPC116.011.08.118,100218501788
CTU48C5XFS2+TXVY82V080C16SMPC116.011.08.118,000218501785
CTF48C5CFS2Y82V080C16SMPC116.011.08.118,000218501782
CTM48C5CFS2Y82V100C16SMPC116.011.78.117,900218501494
CTM48C5CFS2Y82V080C16SMPC116.011.78.118,000218501491
CTF48C5CFS1+JMET16CS2N1-15.211.78.117,300214426743
CTF48C5CFS1+JMC16C2SN1-15.211.78.117,200214426753
CTF48C5CFS1+JMC17C2SN1-15.211.78.117,300214426761
CTF48C5CFS1+JME12C2SN1-15.211.78.117,300214426765
CTF48C5CFS1+JME16C2SN1-15.211.78.117,400214426769
CTF48C5CFS1+JMET12CS2N1-15.211.78.117,300214426900
CTF36B5CDS1+JMC12B2SN1-15.211.08.117,700214426936
CTF36B5CDS1+JME12B2SN1-15.211.08.117,400214427024
JHE42C5CF2SS1-15.211.78.117,300214427266
JHC42C5CF2SS1-15.211.78.117,500214427268
CTF48C5CFS1+JMVT17CC2N1-15.211.78.117,200214427274
CTF48C5CFS1+JMVT16CC2N1-15.211.78.117,500214427276
CTU36B5XDS1+JMC12B2SN1+TXV-15.211.08.117,700214807472
CTU36B5XDS1+JME12B2SN1+TXV-15.211.08.117,400214807473
CTU48C5XFS1+JMET16CS2N1+TXV-15.211.78.117,300214807530
CTU48C5XFS1+JMC16C2SN1+TXV-15.211.78.117,200214807531
CTU48C5XFS1+JMC17C2SN1+TXV-15.211.78.117,300214807535
CTU48C5XFS1+JME12C2SN1+TXV-15.211.78.117,300214807536
CTU48C5XFS1+JME16C2SN1+TXV-15.211.78.117,400214807538
CTU48C5XFS1+JMET12CS2N1+TXV-15.211.78.117,300214807556
CTU48C5XFS1+JMVT17CC2N1+TXV-15.211.78.117,200214807561
CTU48C5XFS1+JMVT16CC2N1+TXV-15.211.78.117,500214807562
CTF48C5CFS1Y82E100C20LMPS115.211.78.117,900215742769
CTU48C5XFS1+TXVY82E100C20LMPS115.211.78.117,900215742770
CTF48C5CFS1Y82E100C16LMPS115.211.78.118,000215742775
CTU48C5XFS1+TXVY82E100C16LMPS115.211.78.118,000215742776
CTF48C5CFS1Y82E120C20LMPS115.211.78.118,100215742779
CTU48C5XFS1+TXVY82E120C20LMPS115.211.78.118,100215742780
CTM36C5CDS1Y82E080C16LMPS115.211.78.117,400216437578
CTM48D5CFS1+JMVT20DC2N1-15.211.78.117,700216437604
CTM48D5CFS1+JMC20D2SN1-15.211.78.117,700216437605
CTM48C5CFS1Y82E100C20LMPS115.211.78.117,900216437606
CTM48D5CFS1+JME18D2SN1-15.212.08.117,600216437607
CTM48C5CFS1Y82E080C16LMPS115.211.78.118,000216437609
CTM48C5CFS1Y82E100C16LMPS115.211.78.118,000216437611
CTM48C5CFS1Y82E120C20LMPS115.211.78.118,100216437612
CTM48C5CFS1+JMET16CS2N1-15.211.78.117,600214426745
CTM48C5CFS1+JME12C2SN1-15.212.08.117,600214426739
CTM48C5CFS1+JMC16C2SN1-15.212.08.117,500214426749
CTM48C5CFS1+JMET12CS2N1-15.211.78.117,600214426741
CTM48C5CFS1+JMC17C2SN1-15.212.08.117,500214426763
CTM48C5CFS1+JME16C2SN1-15.212.08.117,500214426747
CTM48C5CFS1Y81E100C16SMPS115.211.78.117,800214426914
CTM36C5CDS1+JME16C2SN1-15.211.78.117,600214426926
CTM36C5CDS1Y81E080C16SMPS115.211.78.117,400214426946
CTM48C5CFS1Y81E120C16SMPS115.211.78.117,700214426916
CTM36C5CDS1+JME12C2SN1-15.211.78.117,600214426980
CTM48C5CFS1+JMVT16CC2N1-15.212.08.117,500214427272
Yearly running cost in 10 large cities$979-$2,482

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH536E2S11?
The York YH536E2S11 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 304 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH536E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the York YH536E2S11 cost to run per year?
At its rated efficiency it costs about $979-$2,482 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,188 in Phoenix and $2,059 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH536E2S11?
ENERGY STAR lists 304 certified combinations for this outdoor unit. The highest-rated ones use CTM48C5CFS1, CTF48C5CFS1, CTU48C5XFS1+TXV.
What refrigerant does the York YH536E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,169/yrYou save $520/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH536E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,169
Current system, per year
$1,689
You save per year
$520
Payback
24.0 years
Net after 10 years
-$7,295

Cooling $735Heating $434Electricity used: 7,306 kWhSaved vs. a minimum-efficiency heat pump: $122

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.