2-ton central heat pump · DZ6VS
Daikin DZ6VSA241EA
Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #230 of 331 2 ton central heat pumps for cooling efficiency, and costs about $708 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.6 Heating efficiency over a seasonAverage · beats 45%
- EER2
- 10.0 Cooling efficiency on a 95°F dayBelow average · beats 10%
- Heat at 5°F
- 16,100 BTU/h70% of its 47°F outputBelow average · beats 39%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 16,100 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 24 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Daikin |
| Also sold as | Amana |
| Outdoor unit model | DZ6VSA241EA |
| Series | DZ6VS |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | May 6, 2025 |
| Last certified | August 19, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 17.0) |
| EER2Efficiency at 95°F outdoors | 10.0 |
| Cooling capacity | 23,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.6 |
| Capacity at 47°F | 23,000 BTU/h |
| Capacity at 17°F | 16,000 BTU/h |
| Capacity at 5°F | 16,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CA*EA2422*4A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CA*EA2422*4A · cold climate | D*80TC0603B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362002 |
| CA*EA2422*4A · cold climate | D*80TC0604B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362003 |
| CA*EA2422*4A · cold climate | D*80TC0804C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362005 |
| CA*EA2422*4A · cold climate | D*80TC0803B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362004 |
| CA*EA2422*4A · cold climate | D*80TC0805C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362006 |
| CA*EA2422*4A · cold climate | D*80TC1005C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362007 |
| CA*EA3026*4A · cold climate | D*80TC0603B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362013 |
| CA*EA3026*4A · cold climate | D*80TC0604B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362014 |
| CA*EA3026*4A · cold climate | D*80TC0803B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362015 |
| CA*EA3026*4A · cold climate | D*80TC0804C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362016 |
| CA*EA3026*4A · cold climate | D*80TC0805C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362017 |
| CA*EA3026*4A · cold climate | D*80TC1005C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362018 |
| CA*EA2422*4B · cold climate | D*80TC0603B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362048 |
| CA*EA2422*4B · cold climate | D*80TC0604B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362049 |
| CA*EA2422*4B · cold climate | D*80TC0803B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362050 |
| CA*EA2422*4B · cold climate | D*80TC0804C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362051 |
| CA*EA2422*4B · cold climate | D*80TC0805C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362052 |
| CA*EA2422*4B · cold climate | D*80TC1005C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362053 |
| CA*EA3026*4B · cold climate | D*80TC0603B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362059 |
| CA*EA3026*4B · cold climate | D*80TC0604B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362060 |
| CA*EA3026*4B · cold climate | D*80TC0803B*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362061 |
| CA*EA3026*4B · cold climate | D*80TC0804C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362062 |
| CA*EA3026*4B · cold climate | D*80TC0805C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362063 |
| CA*EA3026*4B · cold climate | D*80TC1005C*A* | 17.0 | 10.0 | 8.6 | 16,100 | 217362064 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Daikin DZ6VSA241EA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Amana ASZS60241EA
Yearly running cost in 10 large cities
- Phoenix, AZ$782/yr
- Miami, FL$636/yr
- Houston, TX$701/yr
- Atlanta, GA$708/yr
- Los Angeles, CA$689/yr
- New York, NY$1,691/yr
- Chicago, IL$1,373/yr
- Denver, CO$1,141/yr
- Seattle, WA$701/yr
- Minneapolis, MN$1,412/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Daikin DZ6VSA241EA?
- The Daikin DZ6VSA241EA is rated at up to 17.0 SEER2 and 10.0 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Daikin DZ6VSA241EA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 16,100 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Daikin DZ6VSA241EA cost to run per year?
- At its rated efficiency it costs about $636-$1,691 a year in electricity in large U.S. cities, depending on climate and local rates - for example $782 in Phoenix and $1,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Daikin DZ6VSA241EA the same as the Amana ASZS60241EA?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Daikin DZ6VSA241EA?
- ENERGY STAR lists 24 certified combinations for this outdoor unit. The highest-rated ones use CA*EA2422*4A, CA*EA3026*4A, CA*EA2422*4B.
- What refrigerant does the Daikin DZ6VSA241EA use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Continental WSEHV2436RA1-C · cold climate17.0 SEER2 · 9.0 HSPF2
- Armstrong Air 4SHP17LE124P-**A17.0 SEER2 · 8.2 HSPF2
- AC Pro AUD36W/A-D(U) · cold climate17.0 SEER2 · 9.0 HSPF2
- Blueridge BHP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Trane 5HCL5024A1 · cold climate17.0 SEER2 · 9.2 HSPF2
- Comfort-Aire HRG1524S1R-**A17.0 SEER2 · 8.2 HSPF2
- Star Air Kontrol SAK-24ADN2-M18M · cold climate17.0 SEER2 · 9.2 HSPF2
- Concord 4HP17L24P-**A17.0 SEER2 · 8.2 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 19, 2026. How we use the data.