2-ton central heat pump · NS17H
GE NS17H24SA4-**A
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #235 of 331 2 ton central heat pumps for cooling efficiency, and costs about $706 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 11,500 BTU/h48% of its 47°F outputVery good · beats 70%
A good fit if…
- You want a choice of indoor units - 253 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS17H24SA4-**A |
| Series | NS17H |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 18, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.4-17.0) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 22,600-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.2 |
| Capacity at 47°F | 21,200-22,600 BTU/h |
| Capacity at 17°F | 13,400-14,700 BTU/h |
| Capacity at 5°F | 10,200-11,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.16 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NCHC30BT4+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 253 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NCHC30BT4+TDR | NF80U090S4B-* | 17.0 | 14.0 | 8.0 | 10,400 | 210262091 |
| NCHC30BT4+TDR | NF80U090T4B-* | 17.0 | 14.0 | 8.0 | 10,300 | 210262087 |
| NCHC30BT5D-**+TDR | NF80U090T4B* | 17.0 | 14.0 | 8.0 | 10,300 | 217491084 |
| NCHC30BT5D-**+TDR | NF80L090S4B* | 17.0 | 14.0 | 8.0 | 10,400 | 217490968 |
| NCHC30BT5D-**+TDR | NF80U090S4B* | 17.0 | 14.0 | 8.0 | 10,400 | 217491057 |
| NCHC30AT4+TDR | NF80X060V3A-* | 16.8 | 14.0 | 8.1 | 10,400 | 210262082 |
| NCHC30AT5D-**+TDR | NF80X060V3A* | 16.8 | 14.0 | 8.1 | 10,400 | 217491165 |
| NCHC30BT4+TDR | NF80X080V4B-* | 16.8 | 14.0 | 8.0 | 10,400 | 210262094 |
| NCHC30BT4+TDR | NF80U070S3B-* | 16.8 | 13.5 | 8.0 | 10,400 | 210262090 |
| NCHC30BT5D-**+TDR | NF80L070S3B* | 16.8 | 13.5 | 8.0 | 10,400 | 217490956 |
| NCHC30BT5D-**+TDR | NF80U070S3B* | 16.8 | 13.5 | 8.0 | 10,400 | 217491024 |
| NCHC30BT5D-**+TDR | NF80X080V4B* | 16.8 | 14.0 | 8.0 | 10,400 | 217491185 |
| NCHC30BT4+TDR | NF97U070M3B-* | 16.8 | 13.5 | 7.8 | 10,400 | 210262098 |
| NCHC30BT4+TDR | NF97U070V3B | 16.8 | 13.5 | 7.8 | 10,400 | 215283296 |
| NCHC30BT5D-**+TDR | NF97U070V3B | 16.8 | 13.5 | 7.8 | 10,400 | 215283301 |
| NCHC30BT4+TDR | NF98U070M3B | 16.8 | 13.5 | 7.8 | 10,400 | 215438183 |
| NCHC30BT5D-**+TDR | NF97U070V3B* | 16.8 | 13.5 | 7.8 | 10,400 | 217491398 |
| NCHC30BT5D-**+TDR | NF97U070M3B* | 16.8 | 13.5 | 7.8 | 10,400 | 217491385 |
| NCHC30AT4+TDR | NF80U045T3A-* | 16.6 | 13.5 | 8.1 | 10,400 | 210262077 |
| NCHC30AT5D-**+TDR | NF80U045T3A* | 16.6 | 13.5 | 8.1 | 10,400 | 217491003 |
| NCUC30AT4+TDR | NF80X060V3A-* | 16.6 | 13.5 | 8.0 | 10,200 | 210262130 |
| NCUU30BP4+TDR+TXV | NF80U090S4B-* | 16.6 | 13.5 | 8.0 | 10,400 | 210262058 |
| NCUU30AP4+TDR+TXV | NF80X060V3A-* | 16.6 | 13.5 | 8.0 | 10,200 | 210262049 |
| NCUC30BT4+TDR | NF80U090S4B-* | 16.6 | 13.5 | 8.0 | 10,400 | 210262139 |
| NCUC30BT5D-**+TDR | NF80U090S4B* | 16.6 | 13.5 | 8.0 | 10,400 | 217491059 |
| NCUC30BT5D-**+TDR | NF80L090S4B* | 16.6 | 13.5 | 8.0 | 10,400 | 217490970 |
| NCUC30AT5D-**+TDR | NF80X060V3A* | 16.6 | 13.5 | 8.0 | 10,200 | 217491167 |
| NCHC30BT4+TDR | NF97X040V3B-* | 16.6 | 13.5 | 7.8 | 10,400 | 210262096 |
| NCHC30BT4+TDR | NF97X060V3B-* | 16.6 | 13.5 | 7.8 | 10,400 | 210262097 |
| NCHC30BT4+TDR | NF97U045V3B | 16.6 | 13.5 | 7.8 | 10,400 | 215283294 |
| NCHC30BT5D-**+TDR | NF97U045V3B | 16.6 | 13.5 | 7.8 | 10,400 | 215283299 |
| NCHC30BT5D-**+TDR | NF97U045V3B* | 16.6 | 13.5 | 7.8 | 10,400 | 217491372 |
| NCHC30BT5D-**+TDR | NF96U045V3B* | 16.6 | 13.5 | 7.8 | 10,400 | 217491281 |
| NCHC30BT5D-**+TDR | NF97X040V3B* | 16.6 | 13.5 | 7.8 | 10,400 | 217491452 |
| NCHC30BT5D-**+TDR | NF97X060V3B* | 16.6 | 13.5 | 7.8 | 10,400 | 217491465 |
| NCDC3036CT4+TDR | NF96D090S4C-* | 16.4 | 13.5 | 8.2 | 11,200 | 213355823 |
| NCDC36CT5D-**+TDR | NF96D090S4C* | 16.4 | 13.5 | 8.2 | 11,200 | 217491260 |
| NCHC30AT4+TDR | NF80U070V3A-* | 16.4 | 13.5 | 8.1 | 10,600 | 210262083 |
| NCHC30AT5D-**+TDR | NF80U070V3A* | 16.4 | 13.5 | 8.1 | 10,600 | 217491048 |
| NCHC30AT4+TDR | NF80U070S3A-* | 16.4 | 13.5 | 8.0 | 10,400 | 210262080 |
| NCUC30BT4+TDR | NF80U090T4B-* | 16.4 | 13.5 | 8.0 | 10,400 | 210262135 |
| NCHC30AT4+TDR | NF80U045S3A-* | 16.4 | 13.5 | 8.0 | 10,200 | 210262079 |
| NCHC30AT4+TDR | NF80L070S3A-* | 16.4 | 13.5 | 8.0 | 10,400 | 210262081 |
| NCUU30BP4+TDR+TXV | NF80U090T4B-* | 16.4 | 13.5 | 8.0 | 10,400 | 210262054 |
| NCUC30BT5D-**+TDR | NF80U090T4B* | 16.4 | 13.5 | 8.0 | 10,400 | 217491086 |
| NCHC30AT5D-**+TDR | NF80U070S3A* | 16.4 | 13.5 | 8.0 | 10,400 | 217491014 |
| NCHC30AT5D-**+TDR | NF80U045S3A* | 16.4 | 13.5 | 8.0 | 10,200 | 217490994 |
| NCHC30AT5D-**+TDR | NF80L045S3A* | 16.4 | 13.5 | 8.0 | 10,200 | 217490937 |
| NCHC30AT5D-**+TDR | NF80L070S3A* | 16.4 | 13.5 | 8.0 | 10,400 | 217490946 |
| NCUC24BT4+TDR | NF80X080V4B-* | 16.4 | 13.0 | 7.8 | 10,400 | 210262118 |
| NCUC24BT4+TDR | NF80U090S4B-* | 16.4 | 13.5 | 7.8 | 10,400 | 210262115 |
| NCUC30BT4+TDR | NF80U070S3B-* | 16.4 | 13.5 | 7.8 | 10,400 | 210262138 |
| NCUC24AT4+TDR | NF80U045T3A-* | 16.4 | 13.0 | 7.8 | 10,200 | 210262101 |
| NCUC24AT4+TDR | NF80X060V3A-* | 16.4 | 13.5 | 7.8 | 10,400 | 210262106 |
| NCUC30AT4+TDR | NF80U045T3A-* | 16.4 | 13.5 | 7.8 | 10,200 | 210262125 |
| NCHC30BT4+TDR | NF80X080S4B-* | 16.4 | 13.5 | 7.8 | 10,600 | 210262084 |
| NCUC24BT4+TDR | NF80U090T4B-* | 16.4 | 13.5 | 7.8 | 10,400 | 210262111 |
| NCHC30BT4+TDR | NF80U090V4B-* | 16.4 | 13.5 | 7.8 | 10,400 | 210262095 |
| NCUU30BP4+TDR+TXV | NF80U070S3B-* | 16.4 | 13.5 | 7.8 | 10,400 | 210262057 |
| NCUU24AP4+TDR+TXV | NF80U045T3A-* | 16.4 | 13.0 | 7.8 | 10,200 | 210262020 |
Yearly running cost in 10 large cities
- Phoenix, AZ$789/yr
- Miami, FL$646/yr
- Houston, TX$707/yr
- Atlanta, GA$706/yr
- Los Angeles, CA$685/yr
- New York, NY$1,676/yr
- Chicago, IL$1,359/yr
- Denver, CO$1,128/yr
- Seattle, WA$692/yr
- Minneapolis, MN$1,395/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS17H24SA4-**A?
- The GE NS17H24SA4-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 253 certified matchups SEER2 ranges from 15.4-17.0.
- Is the GE NS17H24SA4-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the GE NS17H24SA4-**A cost to run per year?
- At its rated efficiency it costs about $646-$1,676 a year in electricity in large U.S. cities, depending on climate and local rates - for example $789 in Phoenix and $1,395 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS17H24SA4-**A?
- ENERGY STAR lists 253 certified combinations for this outdoor unit. The highest-rated ones use NCHC30BT4+TDR, NCHC30BT5D-**+TDR, NCHC30AT4+TDR.
- What refrigerant does the GE NS17H24SA4-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Concord 4HP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Lennox EL17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- Comfort-Aire HRG1524S1R-**A17.0 SEER2 · 8.2 HSPF2
- Lennox ML17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- Blueridge BHP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Trane 5TWR6024A117.0 SEER2 · 8.1 HSPF2
- Armstrong Air 4SHP17LE124P-**A17.0 SEER2 · 8.2 HSPF2
- Trane 5TWX6024A117.0 SEER2 · 8.1 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.