2-ton central heat pump · NS18H SERIES
GE NS18H36MA4-
Very good cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #63 of 331 2 ton central heat pumps for cooling efficiency, and costs about $704 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 18,400 BTU/h53% of its 47°F outputVery good · beats 71%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 35 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS18H36MA4- |
| Series | NS18H SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2023 |
| Last certified | June 4, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 17.1-19.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.3 |
| Cooling capacity | 22,000-34,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.5 |
| Capacity at 47°F | 22,000-34,400 BTU/h |
| Capacity at 17°F | 15,000-22,600 BTU/h |
| Capacity at 5°F | 14,500-18,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.85-2.18 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM36V1TA4- at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NAM36V1TA4- | - | 19.0 | 11.7 | 8.5 | 18,100 | 209941275 |
| NCHC30BT4 | NF96U045V3B-* | 19.0 | 12.3 | 8.5 | 15,000 | 209941314 |
| NCHC30BT4 | NF96U070V3B-* | 19.0 | 12.3 | 8.5 | 14,900 | 209941315 |
| NAM36V2TA4 | - | 19.0 | 11.7 | 8.5 | 18,400 | 213255778 |
| NAM30V2TA4 | - | 19.0 | 12.3 | 8.5 | 15,300 | 213255777 |
| NAM24V2TA4 | - | 19.0 | 12.3 | 8.5 | 14,500 | 213255776 |
| NCHC30BT4+TDR | NF98U070M3B | 19.0 | 12.3 | 8.5 | 14,900 | 215835864 |
| NCHC30BT5D-**+TDR | NF98U070M3B | 19.0 | 12.3 | 8.5 | 14,900 | 215835871 |
| NCUC30BT4 | NF96U070V3B-* | 19.0 | 12.3 | 8.1 | 14,800 | 209941252 |
| NCUU30BP4+TXV | NF96U070V3B-* | 19.0 | 12.3 | 8.1 | 14,800 | 209941250 |
| NCUC30BT4+TDR | NF98U070M3B | 19.0 | 12.3 | 8.1 | 14,800 | 215835896 |
| NCUU30BP4+TDR+TXV | NF98U070M3B | 19.0 | 12.3 | 8.1 | 14,800 | 215835963 |
| NCUC30BT5D-**+TDR | NF98U070M3B | 19.0 | 12.3 | 8.1 | 14,800 | 215835899 |
| NCUC24BT4 | NF96U070V3B-* | 19.0 | 12.3 | 7.8 | 15,200 | 209941251 |
| NCUC24BT4 | NF96U045V3B-* | 19.0 | 12.3 | 7.8 | 15,300 | 209941242 |
| NCUU24BP4+TXV | NF96U045V3B-* | 19.0 | 12.3 | 7.8 | 15,300 | 209941241 |
| NCUU24BP4+TXV | NF96U070V3B-* | 19.0 | 12.3 | 7.8 | 15,200 | 209941249 |
| NCHC30BT4 | NF96U045S3B-* | 18.5 | 12.3 | 8.5 | 15,300 | 209941214 |
| NAM24V1TA4- | - | 18.5 | 12.3 | 8.5 | 15,400 | 209941285 |
| NAM18V1TA4- | - | 18.5 | 12.3 | 8.5 | 15,200 | 209941284 |
| NAM30V1TA4- | - | 18.5 | 12.3 | 8.5 | 15,200 | 209941316 |
| NCUC30BT4 | NF96U045V3B-* | 18.5 | 12.3 | 8.1 | 14,900 | 209941313 |
| NCUU30BP4+TXV | NF96U045V3B-* | 18.5 | 12.3 | 8.1 | 14,900 | 209941312 |
| NCHC30BT4 | NF96U070S3B-* | 18.0 | 12.3 | 8.5 | 15,300 | 209941223 |
| NCUC24BT4 | NF96U045S3B-* | 18.0 | 12.3 | 7.8 | 15,600 | 209941212 |
| NCUU24BP4+TXV | NF96U045S3B-* | 18.0 | 12.3 | 7.8 | 15,600 | 209941210 |
| NCUC24BT4 | NF96U070S3B-* | 18.0 | 12.3 | 7.8 | 15,600 | 209941311 |
| NCUU24BP4+TXV | NF96U070S3B-* | 18.0 | 12.3 | 7.8 | 15,600 | 209941310 |
| NAM42V1TA4- | - | 17.5 | 11.7 | 8.5 | 18,200 | 209941279 |
| NAM30E1TA4- | - | 17.5 | 12.3 | 8.5 | 15,300 | 209941283 |
| NCUU30BP4+TXV | NF96U045S3B-* | 17.5 | 12.3 | 8.1 | 15,200 | 209941211 |
| NAM24E1TA4- | - | 17.5 | 12.3 | 8.1 | 14,900 | 209941282 |
| NAM18P1TA4 | - | 17.1 | 12.3 | 8.5 | 14,700 | 209941280 |
| NCUC30BT4 | NF96U070S3B-* | 17.1 | 12.3 | 7.8 | 15,200 | 209941222 |
| NCUU30BP4+TXV | NF96U070S3B-* | 17.1 | 12.3 | 7.8 | 15,200 | 209941221 |
Yearly running cost in 10 large cities
- Phoenix, AZ$743/yr
- Miami, FL$586/yr
- Houston, TX$667/yr
- Atlanta, GA$704/yr
- Los Angeles, CA$691/yr
- New York, NY$1,717/yr
- Chicago, IL$1,401/yr
- Denver, CO$1,170/yr
- Seattle, WA$723/yr
- Minneapolis, MN$1,450/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS18H36MA4-?
- The GE NS18H36MA4- is rated at up to 19.0 SEER2 and 11.7 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 35 certified matchups SEER2 ranges from 17.1-19.0.
- Is the GE NS18H36MA4- good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the GE NS18H36MA4- cost to run per year?
- At its rated efficiency it costs about $586-$1,717 a year in electricity in large U.S. cities, depending on climate and local rates - for example $743 in Phoenix and $1,450 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS18H36MA4-?
- ENERGY STAR lists 35 certified combinations for this outdoor unit. The highest-rated ones use NAM36V1TA4-, NCHC30BT4, NAM36V2TA4.
- What refrigerant does the GE NS18H36MA4- use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Century HRG1836S1P19.0 SEER2 · 8.5 HSPF2
- TCL H24TDH17XAC · cold climate19.0 SEER2 · 8.5 HSPF2
- Armstrong Air 4SHP18LX136P19.0 SEER2 · 8.5 HSPF2
- TCL THH24TDI2NAF2H26 · cold climate19.0 SEER2 · 8.5 HSPF2
- ALLIED 4HP18V36P19.0 SEER2 · 8.5 HSPF2
- York YZV24B2119.0 SEER2 · 8.5 HSPF2
- Goodman GZV7SA2410A · cold climate19.0 SEER2 · 8.8 HSPF2
- Bosch BOHA-24MTB-M18S · cold climate18.9 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 4, 2026. How we use the data.